How to choose
Direct-acting or pilot-operated
Use a direct-acting valve to protect against over-pressure: it is very fast, tolerant of dirt and stable, and it is the safe choice when in doubt. Use a pilot-operated valve to regulate pressure: its pressure rises little as flow increases and it is easy to adjust. Then choose the setting range that covers your working setting and the capacity for the full flow the valve may have to pass.