About this range

01Should I use meter-in or meter-out speed control on a cylinder?
For a double-acting cylinder, meter-out in most cases: the controller throttles the air leaving the cylinder, so the piston moves against a cushion of back pressure and runs smoothly even when the load changes or pulls. Meter-in throttles the air entering and suits single-acting cylinders, which have no exhaust air on the working side, and some very short-stroke applications.
02What does a quick exhaust valve do?
It lets a cylinder exhaust straight to atmosphere at the cylinder port instead of pushing its air back through the tube and the directional valve. That speeds up the stroke it serves, and it is also used to vent a large volume quickly. Fit it directly in, or very close to, the cylinder port.
03What is the difference between a needle valve and a flow control valve?
A needle valve throttles flow equally in both directions. A flow control valve adds a built-in check valve in parallel, so it throttles one direction and lets the other pass freely; that is what lets a cylinder be speed-controlled on one stroke and run free on the other.
04Where should a cylinder speed controller be fitted?
In or close to the cylinder port. The less air volume between the controller and the piston, the more precisely it controls speed. A banjo or elbow-type speed controller screwed into the cylinder port is the common choice; an exhaust-port flow control or speed-control silencer fitted to the valve is easier to reach, but controls less precisely on long tube runs.
05What is an in-tank check valve on a compressor?
A check valve fitted where the compressor discharge line enters the receiver. It lets air into the tank and stops tank air flowing back through the discharge line into the pump when the compressor stops. The Conrader CTA to CTL and CAC series and the Kingston KCV234 Series on this shelf are in-tank check valves; order by the maker part number so that thread and size match.
06What is a minimum pressure check valve?
A valve fitted to oil-flooded rotary screw compressors. It holds a minimum pressure in the oil separator vessel, so that oil keeps circulating and the separator works properly when demand is low, and it stops air flowing back from the system when the compressor unloads. The Conrader CMP Series on this shelf is of this type.