SUN HYDRAULICSIH-SUN-PP-B

Sun Hydraulics Pilot-Operated, Pressure Reducing/Relieving Valve — PPBB, PPDB, PPFB, PPHB, PPJB, Series 0 to 4

Relief, Reducing & Sequence CartridgesEx-stock · delivery in 3 days
Sun Hydraulics PPDB pilot-operated pressure reducing/relieving valve, series 1, T-11A cavity — dimension drawing
VIEW 01·Sun Hydraulics PPDB pilot-operated pressure reducing/relieving valve, series 1, T-11A cavity — dimension drawing
1 / 3

Sun Hydraulics pilot-operated pressure reducing/relieving valve: PPBB, PPDB, PPFB, PPHB, PPJB, series 0 to 4, 5 gpm to 80 gpm (20 L/min to 320 L/min), T-163A, T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Pilot-Operated Pressure Reducing/Relieving Valve
  • Capacity: 5 gpm to 80 gpm (20 L/min to 320 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-163A, T-11A, T-2A, T-17A, T-19A
Valve function
Pilot-Operated Pressure Reducing/Relieving Valve
Series (frame sizes)
0 to 4
Cavity
T-163A, T-11A, T-2A, T-17A, T-19A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A pilot-operated reducing/relieving cartridge holds a constant reduced pressure at port 1 from a higher supply at port 2 and relieves port 1 to tank (port 3) at full flow if it is pushed above the setting. The pilot stage gives a flat pressure curve and very little dead band between reducing and relieving.

Sizes and cavities

Sun Hydraulics builds this valve in 5 sizes. The series sets the cavity it screws into and its flow capacity:

  • PPBB — series 0, T-163A cavity, 5 gpm (20 L/min), 0-series
  • PPDB — series 1, T-11A cavity, 10 gpm (40 L/min)
  • PPFB — series 2, T-2A cavity, 20 gpm (80 L/min)
  • PPHB — series 3, T-17A cavity, 40 gpm (160 L/min)
  • PPJB — series 4, T-19A cavity, 80 gpm (320 L/min)

Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)

Configuration options

The letters after the base model code choose these options (shown for PPDB; a size may add or drop a choice):

  • Control: L — Standard Screw Adjustment, C — Tamper Resistant - Factory Set, K — Handknob, Y — Tri-Grip Handknob, M — Capped Screw Adjustment with Lockwire Holes, O — Handknob with Panel Mount, Q — Capped and Lockwired, W — Hex Wrench Adjustment
  • Setting range: A — 100 - 3000 psi (7 - 210 bar), 200 psi (14 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 200 psi (14 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 200 psi (14 bar) Standard Setting, N — 60 - 800 psi (4 - 55 bar), 200 psi (14 bar) Standard Setting, Q — 60 - 400 psi (4 - 28 bar), 200 psi (14 bar) Standard Setting, C — 150 - 6000 psi (10,5 - 420 bar), 200 psi (14 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 200 psi (14 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, H — 30 - 3000 psi (2 - 210 bar), 200 psi (14 bar) Standard Setting, J — 25 - 1500 psi (1,7 - 105 bar), 200 psi (14 bar) Standard Setting, K — 75 - 1500 psi (5 - 105 bar), 200 psi (14 bar) Standard Setting, O — 15 - 400 psi (1 - 28 bar), 200 psi (14 bar) Standard Setting, P — 40 - 400 psi (2,8 - 28 bar), 200 psi (14 bar) Standard Setting
  • Seal material: N — Buna-N, V — Viton
  • Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Option rules: If the modifier is /AP, the control must be C, L or Y; If the modifier is /LH, the control must be C or L.

Selection notes

  • Pilot-operated reducing valves are not fast-acting; for quick response use a direct-acting one.
  • If pilot-flow consumption matters, consider a direct-acting reducing/relieving valve.
  • Maximum inlet pressure depends on the adjustment range — check the data.
  • Drilled-piston-orifice versions suit punishing duty.

Where it is used

Secondary pressure circuits that must hold their setting both ways — clamps, presses, test rigs.

Installation and seal kits

Valve hex 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 0: Buna: 990163007, EPDM: 990163014, Polyurethane: 990163002, Viton: 990163006; series 1: Buna: 990011007, EPDM: 990011014, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, EPDM: 990017014, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example PPDBLAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.

Identification

ParameterValue
Valve functionPilot-Operated Pressure Reducing/Relieving Valve
Series (frame sizes)0 to 4
CavityT-163A, T-11A, T-2A, T-17A, T-19A

Performance

ParameterValue
Capacity5 gpm to 80 gpm (20 L/min to 320 L/min)
Max operating pressure5000 psi (350 bar)
Setting rangeA — 100 - 3000 psi (7 - 210 bar), 200 psi (14 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 200 psi (14 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 200 psi (14 bar) Standard Setting, N — 60 - 800 psi (4 - 55 bar), 200 psi (14 bar) Standard Setting, Q — 60 - 400 psi (4 - 28 bar), 200 psi (14 bar) Standard Setting, C — 150 - 6000 psi (10,5 - 420 bar), 200 psi (14 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 200 psi (14 bar) Standard Settin

Configuration

ParameterValue
Control / adjustmentL — Standard Screw Adjustment, C — Tamper Resistant - Factory Set, K — Handknob, Y — Tri-Grip Handknob, M — Capped Screw Adjustment with Lockwire Holes, O — Handknob with Panel Mount, Q — Capped and Lockwired, W — Hex Wrench Adjustment
Seal materialN — Buna-N, V — Viton
Material / coating/AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Installation

ParameterValue
Valve hex size3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm)
Installation torque20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm)
Seal kitsseries 0: Buna: 990163007, EPDM: 990163014, Polyurethane: 990163002, Viton: 990163006; series 1: Buna: 990011007, EPDM: 990011014, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, EPDM: 990017014, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006
Weight.30 lb (0,15 kg) to 3.10 lb (1,40 kg)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

Also known as

The same part, in the designations used across European and Gulf trade catalogues.

de
Reduzierung
fr
réducteur
es
reductor
it
riduzione
RELATED · OFTEN PAIRED WITH

Engineers viewing this also looked at