Sun Hydraulics Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4 — PVDA, PVFA, PVHA, PVJA, Series 1 to 4

Sun Hydraulics pilot-operated reducing/relieving valve with drain to port 4: PVDA, PVFA, PVHA, PVJA, series 1 to 4, 10 gpm to 80 gpm (40 L/min to 320 L/min), T-21A, T-22A, T-23A, T-24A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Pilot-Operated Reducing/Relieving Valve with Drain to Port 4
- Capacity: 10 gpm to 80 gpm (40 L/min to 320 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-21A, T-22A, T-23A, T-24A
- Valve function
- Pilot-Operated Reducing/Relieving Valve with Drain to Port 4
- Series (frame sizes)
- 1 to 4
- Cavity
- T-21A, T-22A, T-23A, T-24A
Product description
A pilot-operated reducing/relieving cartridge whose pilot stage drains through port 4. That makes the setting immune to pressure at the tank port and lets pilot or 2-way valves on port 4 control it remotely.
Sizes and cavities
Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:
- PVDA — series 1, T-21A cavity, 10 gpm (40 L/min)
- PVFA — series 2, T-22A cavity, 20 gpm (80 L/min)
- PVHA — series 3, T-23A cavity, 40 gpm (160 L/min)
- PVJA — series 4, T-24A cavity, 80 gpm (320 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
Configuration options
The letters after the base model code choose these options (shown for PVDA; a size may add or drop a choice):
- Control: C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment, Y — Tri-Grip Handknob, W — Hex Wrench Adjustment
- Setting range: A — 100 - 3000 psi (7 - 210 bar), 200 psi (14 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 200 psi (14 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 200 psi (14 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 200 psi (14 bar) Standard Setting, H — 30 - 3000 psi (2 - 210 bar), 200 psi (14 bar) Standard Setting, J — 25 - 1500 psi (1,7 - 105 bar), 200 psi (14 bar) Standard Setting, N — 60 - 800 psi (4 - 55 bar), 200 psi (14 bar) Standard Setting, Q — 60 - 400 psi (4 - 28 bar), 200 psi (14 bar) Standard Setting
- Seal material: L — Extended Temp. Buna, N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: EPDM seals are not allowed on modifier /AP or /LH; If the modifier is /AP, the control must be C or L; If the modifier is /LH, the control must be C or L.
Selection notes
- Keep pressure at port 3 below 3,000 psi (210 bar).
- Very little dead band between reducing and relieving.
Where it is used
Reduced-pressure branches with back-pressure in the return, or where remote control is wanted.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, EPDM: 990023014, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, EPDM: 990024014, Polyurethane: 990024002, Viton: 990024006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example PVDALAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Pilot-Operated Reducing/Relieving Valve with Drain to Port 4 |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-21A, T-22A, T-23A, T-24A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 10 gpm to 80 gpm (40 L/min to 320 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 100 - 3000 psi (7 - 210 bar), 200 psi (14 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 200 psi (14 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 200 psi (14 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 200 psi (14 bar) Standard Setting, H — 30 - 3000 psi (2 - 210 bar), 200 psi (14 bar) Standard Setting, J — 25 - 1500 psi (1,7 - 105 bar), 200 psi (14 bar) Standard Sett |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment, Y — Tri-Grip Handknob, W — Hex Wrench Adjustment |
| Seal material | L — Extended Temp. Buna, N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, EPDM: 990023014, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, EPDM: 990024014, Polyurethane: 990024002, Viton: 990024006 |
| Weight | .30 lb (0,15 kg) to 3.10 lb (1,40 kg) |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.PVDA
- Series
- 1
- Cavity
- T-21A
- Capacity
- 10 gpm / 40 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.PVFA
- Series
- 2
- Cavity
- T-22A
- Capacity
- 20 gpm / 80 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.PVHA
- Series
- 3
- Cavity
- T-23A
- Capacity
- 40 gpm / 160 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.PVJA
- Series
- 4
- Cavity
- T-24A
- Capacity
- 80 gpm / 320 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4 (PVDA, PVFA, PVHA and others) and what does it do?▾
How do I read the Sun model code for the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4 (PVDA, PVFA, PVHA and others)?▾
What sizes and flow capacities does the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4 come in?▾
What pressure and setting range does the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4 have?▾
Which seal and material options does the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4 come with?▾
How is the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4 adjusted, and which control options are offered?▾
Which seal kit fits the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4 (PVDA, PVFA, PVHA and others)?▾
Which cavity and installation torque does the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4 need?▾
Where is the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4 used?▾
How does the Sun PVDA valve differ from the Sun Direct-Acting, Pressure Reducing/Relieving Valve with Drain to Port 4?▾
Does pressure in the tank line change the setting on the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4?▾
Do you stock the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drain to Port 4 in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
The same part, in the designations used across European and Gulf trade catalogues.
- de
- Reduzierung
- fr
- réducteur
- es
- reductor
- it
- riduzione