Sun Hydraulics Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice — PBDF, PBFF, PBHF, PBJF, Series 1 to 4

Sun Hydraulics pilot-operated pressure reducing valve: PBDF, PBFF, PBHF, PBJF, series 1 to 4, 10 gpm to 80 gpm (40 L/min to 320 L/min), T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Pilot-Operated Pressure Reducing Valve
- Capacity: 10 gpm to 80 gpm (40 L/min to 320 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-11A, T-2A, T-17A, T-19A
- Valve function
- Pilot-Operated Pressure Reducing Valve
- Series (frame sizes)
- 1 to 4
- Cavity
- T-11A, T-2A, T-17A, T-19A
Product description
A pilot-operated reducing cartridge holds a constant reduced pressure at port 1 from a higher supply at port 2, so one pump can serve circuits that need different pressures. A small pilot stage sets the main spool, which gives a very flat pressure-versus-flow curve, good stability and low hysteresis.
Sizes and cavities
Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:
- PBDF — series 1, T-11A cavity, 10 gpm (40 L/min)
- PBFF — series 2, T-2A cavity, 20 gpm (80 L/min)
- PBHF — series 3, T-17A cavity, 40 gpm (160 L/min)
- PBJF — series 4, T-19A cavity, 80 gpm (320 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
Configuration options
The letters after the base model code choose these options (shown for PBDF; a size may add or drop a choice):
- Control: C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment, O — Handknob with Panel Mount, W — Hex Wrench Adjustment
- Setting range: A — 100 - 3000 psi (7 - 210 bar), 200 psi (14 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 200 psi (14 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 200 psi (14 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, G — 60 - 3000 psi (4 - 210 bar), 200 psi (14 bar) Standard Setting, K — 75 - 1500 psi (5 - 105 bar), 200 psi (14 bar) Standard Setting, N — 60 - 800 psi (4 - 55 bar), 200 psi (14 bar) Standard Setting, P — 40 - 400 psi (2,8 - 28 bar), 200 psi (14 bar) Standard Setting, Q — 60 - 400 psi (4 - 28 bar), 200 psi (14 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 200 psi (14 bar) Standard Setting, C — 150 - 6000 psi (10,5 - 420 bar), 200 psi (14 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /AP, the control must be C or L; If the modifier is /LH, the control must be C or L.
Selection notes
- Minimum setting is 75 psi (5 bar) in every range.
- Pressure at port 3 adds one-for-one to the setting.
- Drilled-piston-orifice versions have the main-stage orifice machined into the piston, for punishing duty.
Where it is used
Secondary circuits on presses, machine tools and mobile machines that need a lower working pressure.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example PBDFLAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Pilot-Operated Pressure Reducing Valve |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-11A, T-2A, T-17A, T-19A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 10 gpm to 80 gpm (40 L/min to 320 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 100 - 3000 psi (7 - 210 bar), 200 psi (14 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 200 psi (14 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 200 psi (14 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, G — 60 - 3000 psi (4 - 210 bar), 200 psi (14 bar) Standard Setting, K — 75 - 1500 psi (5 - 105 bar), 200 psi (14 bar) Standard Setting, N — 60 - 800 psi (4 - 55 bar), 200 psi (14 bar) Standard Setting, P — |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment, O — Handknob with Panel Mount, W — Hex Wrench Adjustment |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006 |
| Weight | .30 lb (0,15 kg) to 2.90 lb (1,30 kg) |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.PBDF
- Series
- 1
- Cavity
- T-11A
- Capacity
- 10 gpm / 40 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.PBFF
- Series
- 2
- Cavity
- T-2A
- Capacity
- 20 gpm / 80 L/min
- Max pressure
- —
- Sun Hydraulics part no.PBHF
- Series
- 3
- Cavity
- T-17A
- Capacity
- 40 gpm / 160 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.PBJF
- Series
- 4
- Cavity
- T-19A
- Capacity
- 80 gpm / 320 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice (PBDF, PBFF, PBHF and others) and what does it do?▾
How do I read the Sun model code for the Sun Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice (PBDF, PBFF, PBHF and others)?▾
What sizes and flow capacities does the Sun Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice come in?▾
What pressure and setting range does the Sun Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice have?▾
Which seal and material options does the Sun Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice come with?▾
How is the Sun Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice adjusted, and which control options are offered?▾
Which seal kit fits the Sun Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice (PBDF, PBFF, PBHF and others)?▾
Which cavity and installation torque does the Sun Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice need?▾
Where is the Sun Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice used?▾
How does the Sun PBDF valve differ from the Sun Pilot-Operated, Pressure Reducing/Relieving Valve with Drilled Piston Orifice?▾
Can oil flow back from the reduced side to the supply on the Sun Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice?▾
Is the Sun Pilot-Operated, Pressure Reducing Valve with Drilled Piston Orifice in stock in Dubai, and can you ship it worldwide?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
The same part, in the designations used across European and Gulf trade catalogues.
- de
- Reduzierung
- fr
- réducteur
- es
- reductor
- it
- riduzione