Sun Hydraulics Ventable, Pilot-Operated, Balanced Piston Relief Valve — RVBA, RVCA, RVEA, RVGA, RVIA, Series 0 to 4

Sun Hydraulics ventable pilot-operated relief valve: RVBA, RVCA, RVEA, RVGA, RVIA, series 0 to 4, 7.5 gpm to 120 gpm (30 L/min to 480 L/min), T-163A, T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Ventable Pilot-Operated Relief Valve
- Capacity: 7.5 gpm to 120 gpm (30 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-163A, T-11A, T-2A, T-17A, T-19A
- Valve function
- Ventable Pilot-Operated Relief Valve
- Series (frame sizes)
- 0 to 4
- Cavity
- T-163A, T-11A, T-2A, T-17A, T-19A
Product description
A pilot-operated relief cartridge with a vent port (port 3) connected between the main stage and its pilot. Opening the vent to tank unloads the pump at low pressure; connecting a remote pilot relief to it gives a lower, remotely adjusted setting; a 2-way valve on the vent switches between the two. It is accurate, smooth and quiet, with low pressure rise as flow increases.
Sizes and cavities
Sun Hydraulics builds this valve in 5 sizes. The series sets the cavity it screws into and its flow capacity:
- RVBA — series 0, T-163A cavity, 7.5 gpm (30 L/min), 0-series
- RVCA — series 1, T-11A cavity, 15 gpm (60 L/min)
- RVEA — series 2, T-2A cavity, 30 gpm (120 L/min)
- RVGA — series 3, T-17A cavity, 60 gpm (240 L/min)
- RVIA — series 4, T-19A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 2 in³/min.@1000 psi (30 cc/min.@70 bar), 3 in³/min.@1000 psi (50 cc/min.@70 bar), 4 in³/min.@1000 psi (65 cc/min.@70 bar), 5 in³/min.@1000 psi (80 cc/min.@70 bar)
- Typical response time: 10 ms
Configuration options
The letters after the base model code choose these options (shown for RVCA; a size may add or drop a choice):
- Control: L — Standard Screw Adjustment, C — Tamper Resistant - Factory Set, K — Handknob, O — Handknob with Panel Mount, N — Capped Screw Adjustment with Lockwire Holes, Q — Capped and Lockwired
- Setting range: A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 1000 psi (70 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 150 - 6000 psi (10,5 - 420 bar), 1000 psi (70 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 400 psi (28 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, G — 60 - 3000 psi (4 - 210 bar), 1000 psi (70 bar) Standard Setting, H — 30 - 3000 psi (2 - 210 bar), 1000 psi (70 bar) Standard Setting, Y — 30 - 4500 psi (2 - 315 bar), 1000 psi (70 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton, E — EPDM
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /AP, the control must be C or L; If the modifier is /LH, the control must be C or L; If the seal is E, the control must be C,K,L,N,O or Q.
Selection notes
- A remote pilot relief on the vent port controls the valve below its own setting.
- Accepts full pressure at port 2.
Where it is used
Pump unloading, remote pressure setting and two-pressure circuits on power units and presses.
Installation and seal kits
Valve hex 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 0: Buna: 990163007, EPDM: 990163014, Polyurethane: 990163002, Viton: 990163006; series 1: Buna: 990011007, EPDM: 990011014, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, EPDM: 990017014, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example RVCALAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Ventable Pilot-Operated Relief Valve |
| Series (frame sizes) | 0 to 4 |
| Cavity | T-163A, T-11A, T-2A, T-17A, T-19A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 7.5 gpm to 120 gpm (30 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 1000 psi (70 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 150 - 6000 psi (10,5 - 420 bar), 1000 psi (70 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 400 psi (28 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, G — 60 - 3000 psi (4 - 210 bar), 1000 psi (70 bar) Standa |
| Max leakage | 2 in³/min.@1000 psi (30 cc/min.@70 bar), 3 in³/min.@1000 psi (50 cc/min.@70 bar), 4 in³/min.@1000 psi (65 cc/min.@70 bar), 5 in³/min.@1000 psi (80 cc/min.@70 bar) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | L — Standard Screw Adjustment, C — Tamper Resistant - Factory Set, K — Handknob, O — Handknob with Panel Mount, N — Capped Screw Adjustment with Lockwire Holes, Q — Capped and Lockwired |
| Seal material | N — Buna-N, V — Viton, E — EPDM |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 0: Buna: 990163007, EPDM: 990163014, Polyurethane: 990163002, Viton: 990163006; series 1: Buna: 990011007, EPDM: 990011014, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, EPDM: 990017014, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006 |
| Weight | .30 lb (0,15 kg) to 3.10 lb (1,40 kg) |
Shipping & lead time
Sizes & part numbers
5 sizes- Sun Hydraulics part no.RVBA
- Description
- 0-Series
- Series
- 0
- Cavity
- T-163A
- Capacity
- 7.5 gpm / 30 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVCA
- Description
- Standard
- Series
- 1
- Cavity
- T-11A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVEA
- Description
- Standard
- Series
- 2
- Cavity
- T-2A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVGA
- Description
- Standard
- Series
- 3
- Cavity
- T-17A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVIA
- Description
- Standard
- Series
- 4
- Cavity
- T-19A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Description — What this part number is, as the manufacturer lists it. Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve (RVBA, RVCA, RVEA and others) and what does it do?▾
How do I read the Sun model code for the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve (RVBA, RVCA, RVEA and others)?▾
What sizes and flow capacities does the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve come in?▾
What pressure and setting range does the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve have?▾
Which seal and material options does the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve come with?▾
How is the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve adjusted, and which control options are offered?▾
Which seal kit fits the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve (RVBA, RVCA, RVEA and others)?▾
Which cavity and installation torque does the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve need?▾
Where is the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve used?▾
How does the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve differ from the Sun Pilot-Operated, Balanced Piston Relief Valve?▾
What does venting a relief valve do on the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve?▾
Is the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve in stock in Dubai, and can you ship it worldwide?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations








