Skip to content
SUN HYDRAULICSIH-SUN-RV-A

Sun Hydraulics Ventable, Pilot-Operated, Balanced Piston Relief Valve — RVBA, RVCA, RVEA, RVGA, RVIA, Series 0 to 4

Relief, Reducing & Sequence CartridgesEx-stock · delivery in 3 days
Sun Hydraulics RVCA ventable pilot-operated relief valve, series 1, T-11A cavity — dimension drawing
VIEW 01·Sun Hydraulics RVCA ventable pilot-operated relief valve, series 1, T-11A cavity — dimension drawing
1 / 3

Sun Hydraulics ventable pilot-operated relief valve: RVBA, RVCA, RVEA, RVGA, RVIA, series 0 to 4, 7.5 gpm to 120 gpm (30 L/min to 480 L/min), T-163A, T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Ventable Pilot-Operated Relief Valve
  • Capacity: 7.5 gpm to 120 gpm (30 L/min to 480 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-163A, T-11A, T-2A, T-17A, T-19A
Valve function
Ventable Pilot-Operated Relief Valve
Series (frame sizes)
0 to 4
Cavity
T-163A, T-11A, T-2A, T-17A, T-19A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A pilot-operated relief cartridge with a vent port (port 3) connected between the main stage and its pilot. Opening the vent to tank unloads the pump at low pressure; connecting a remote pilot relief to it gives a lower, remotely adjusted setting; a 2-way valve on the vent switches between the two. It is accurate, smooth and quiet, with low pressure rise as flow increases.

Sizes and cavities

Sun Hydraulics builds this valve in 5 sizes. The series sets the cavity it screws into and its flow capacity:

  • RVBA — series 0, T-163A cavity, 7.5 gpm (30 L/min), 0-series
  • RVCA — series 1, T-11A cavity, 15 gpm (60 L/min)
  • RVEA — series 2, T-2A cavity, 30 gpm (120 L/min)
  • RVGA — series 3, T-17A cavity, 60 gpm (240 L/min)
  • RVIA — series 4, T-19A cavity, 120 gpm (480 L/min)

Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)
  • Maximum leakage: 2 in³/min.@1000 psi (30 cc/min.@70 bar), 3 in³/min.@1000 psi (50 cc/min.@70 bar), 4 in³/min.@1000 psi (65 cc/min.@70 bar), 5 in³/min.@1000 psi (80 cc/min.@70 bar)
  • Typical response time: 10 ms

Configuration options

The letters after the base model code choose these options (shown for RVCA; a size may add or drop a choice):

  • Control: L — Standard Screw Adjustment, C — Tamper Resistant - Factory Set, K — Handknob, O — Handknob with Panel Mount, N — Capped Screw Adjustment with Lockwire Holes, Q — Capped and Lockwired
  • Setting range: A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 1000 psi (70 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 150 - 6000 psi (10,5 - 420 bar), 1000 psi (70 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 400 psi (28 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, G — 60 - 3000 psi (4 - 210 bar), 1000 psi (70 bar) Standard Setting, H — 30 - 3000 psi (2 - 210 bar), 1000 psi (70 bar) Standard Setting, Y — 30 - 4500 psi (2 - 315 bar), 1000 psi (70 bar) Standard Setting
  • Seal material: N — Buna-N, V — Viton, E — EPDM
  • Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Option rules: If the modifier is /AP, the control must be C or L; If the modifier is /LH, the control must be C or L; If the seal is E, the control must be C,K,L,N,O or Q.

Selection notes

  • A remote pilot relief on the vent port controls the valve below its own setting.
  • Accepts full pressure at port 2.

Where it is used

Pump unloading, remote pressure setting and two-pressure circuits on power units and presses.

Installation and seal kits

Valve hex 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 0: Buna: 990163007, EPDM: 990163014, Polyurethane: 990163002, Viton: 990163006; series 1: Buna: 990011007, EPDM: 990011014, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, EPDM: 990017014, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example RVCALAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.

Identification

ParameterValue
Valve functionVentable Pilot-Operated Relief Valve
Series (frame sizes)0 to 4
CavityT-163A, T-11A, T-2A, T-17A, T-19A

Performance

ParameterValue
Capacity7.5 gpm to 120 gpm (30 L/min to 480 L/min)
Max operating pressure5000 psi (350 bar)
Setting rangeA — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 1000 psi (70 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 150 - 6000 psi (10,5 - 420 bar), 1000 psi (70 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 400 psi (28 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, G — 60 - 3000 psi (4 - 210 bar), 1000 psi (70 bar) Standa
Max leakage2 in³/min.@1000 psi (30 cc/min.@70 bar), 3 in³/min.@1000 psi (50 cc/min.@70 bar), 4 in³/min.@1000 psi (65 cc/min.@70 bar), 5 in³/min.@1000 psi (80 cc/min.@70 bar)

Configuration

ParameterValue
Control / adjustmentL — Standard Screw Adjustment, C — Tamper Resistant - Factory Set, K — Handknob, O — Handknob with Panel Mount, N — Capped Screw Adjustment with Lockwire Holes, Q — Capped and Lockwired
Seal materialN — Buna-N, V — Viton, E — EPDM
Material / coating/AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Installation

ParameterValue
Valve hex size3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm)
Installation torque20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm)
Seal kitsseries 0: Buna: 990163007, EPDM: 990163014, Polyurethane: 990163002, Viton: 990163006; series 1: Buna: 990011007, EPDM: 990011014, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, EPDM: 990017014, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006
Weight.30 lb (0,15 kg) to 3.10 lb (1,40 kg)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

RELATED · OFTEN PAIRED WITH