Sun Hydraulics Pilot-Operated, Balanced Poppet Sequence Main Stage with Integral T-8A Control Cavity — RSDS8, RSFS8, RSHS8, RSJS8, Series 1 to 4

Sun Hydraulics sequence main stage with T-8A pilot cavity: RSDS8, RSFS8, RSHS8, RSJS8, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Sequence Main Stage with T-8A Pilot Cavity
- Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-11A, T-2A, T-17A, T-19A
- Valve function
- Sequence Main Stage with T-8A Pilot Cavity
- Series (frame sizes)
- 1 to 4
- Cavity
- T-11A, T-2A, T-17A, T-19A
Product description
An externally drained sequence main stage, balanced piston or balanced poppet, with an integral T-8A pilot cavity. The T-8A pressure-control cartridge fitted there sets the opening pressure relative to the drain at port 3.
Sizes and cavities
Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:
- RSDS8 — series 1, T-11A cavity, 15 gpm (60 L/min)
- RSFS8 — series 2, T-2A cavity, 30 gpm (120 L/min)
- RSHS8 — series 3, T-17A cavity, 60 gpm (240 L/min)
- RSJS8 — series 4, T-19A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Typical response time: 10 ms, 2 ms
Configuration options
The letters after the base model code choose these options (shown for RSJS8; a size may add or drop a choice):
- Setting range: B — 50 psi (3,5 bar), W — 100 psi (7 bar)
- Seal material: N — Buna-N, V — Viton
Selection notes
- The T-8A pilot cartridge is ordered separately.
- Back-pressure at port 2 does not disturb it below its setting.
Where it is used
Remotely or electronically controlled sequence and pressure functions from one cavity.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990402007, Polyurethane: 990002002, Viton: 990402006; series 3: Buna: 990217007, Polyurethane: 990217002, Viton: 990217006; series 4: Buna: 990219007, Viton: 990219006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example RSJS8WN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Sequence Main Stage with T-8A Pilot Cavity |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-11A, T-2A, T-17A, T-19A |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990402007, Polyurethane: 990002002, Viton: 990402006; series 3: Buna: 990217007, Polyurethane: 990217002, Viton: 990217006; series 4: Buna: 990219007, Viton: 990219006 |
| Weight | .30 lb (0,15 kg) to 3.10 lb (1,40 kg) |
Performance
| Parameter | Value |
|---|---|
| Capacity | 15 gpm to 120 gpm (60 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | B — 50 psi (3,5 bar), W — 100 psi (7 bar) |
Configuration
| Parameter | Value |
|---|---|
| Seal material | N — Buna-N, V — Viton |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.RSDS8
- Series
- 1
- Cavity
- T-11A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RSFS8
- Series
- 2
- Cavity
- T-2A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RSHS8
- Series
- 3
- Cavity
- T-17A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RSJS8
- Series
- 4
- Cavity
- T-19A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Pilot-Operated, Balanced Poppet Sequence Main Stage with Integral T-8A Control Cavity (RSDS8, RSFS8, RSHS8 and others) and what does it do?▾
What does the Sun model code for the RSDS8 valve mean?▾
What sizes and flow capacities does the Sun Pilot-Operated, Balanced Poppet Sequence Main Stage with Integral T-8A Control Cavity come in?▾
What pressure and setting range does the Sun Pilot-Operated, Balanced Poppet Sequence Main Stage with Integral T-8A Control Cavity have?▾
Which seal and material options does the Sun Pilot-Operated, Balanced Poppet Sequence Main Stage with Integral T-8A Control Cavity come with?▾
How is the setting of the Sun Pilot-Operated, Balanced Poppet Sequence Main Stage with Integral T-8A Control Cavity chosen?▾
Which seal kit fits the Sun Pilot-Operated, Balanced Poppet Sequence Main Stage with Integral T-8A Control Cavity (RSDS8, RSFS8, RSHS8 and others)?▾
Which cavity and installation torque does the Sun Pilot-Operated, Balanced Poppet Sequence Main Stage with Integral T-8A Control Cavity need?▾
Where is the Sun Pilot-Operated, Balanced Poppet Sequence Main Stage with Integral T-8A Control Cavity used?▾
How does the Sun RSDS8 valve differ from the Sun Pilot-Operated, Balanced Piston Sequence Main Stage with Integral T-8A Control Cavity?▾
What goes in the T-8A cavity on the Sun Pilot-Operated, Balanced Poppet Sequence Main Stage with Integral T-8A Control Cavity?▾
Is the Sun Pilot-Operated, Balanced Poppet Sequence Main Stage with Integral T-8A Control Cavity in stock in Dubai, and can you ship it worldwide?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations