Skip to content
SUN HYDRAULICSIH-SUN-SCEB

Sun Hydraulics Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check — SCEB

Relief, Reducing & Sequence CartridgesEx-stock · delivery in 3 days
Sun Hydraulics SCEB atmospherically vented direct-acting sequence valve, series 2, T-5A cavity — dimension drawing
VIEW 01·Sun Hydraulics SCEB atmospherically vented direct-acting sequence valve, series 2, T-5A cavity — dimension drawing
1 / 3

Sun Hydraulics atmospherically vented direct-acting sequence valve: SCEB, series 2, 30 gpm (120 L/min), T-5A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Atmospherically Vented Direct-Acting Sequence Valve
  • Capacity: 30 gpm (120 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-5A
Valve function
Atmospherically Vented Direct-Acting Sequence Valve
Series (frame sizes)
2
Cavity
T-5A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A direct-acting sequence cartridge whose spring chamber is open to atmosphere instead of a drain port. It opens the second branch once inlet pressure passes the setting; the with-check version also lets oil return freely from port 2 to port 1.

Sizes and cavities

Sun Hydraulics builds this valve in 1 size. The series sets the cavity it screws into and its flow capacity:

  • SCEB — series 2, T-5A cavity, 30 gpm (120 L/min)

Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)
  • Maximum leakage: 10 drops/min. (0,7 cc/min)
  • Typical response time: 2 ms
  • Check cracking pressure: 25 psi (1,7 bar)

Configuration options

The letters after the base model code choose these options (shown for SCEB; a size may add or drop a choice):

  • Control: C — Tamper Resistant - Factory Set, L — Standard Screw Adjustment, K — Handknob
  • Setting range: A — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 300 - 1500 psi (20 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 2000 - 6000 psi (140 - 420 bar), 2000 psi (140 bar) Standard Setting, D — 200 - 800 psi (14 - 55 bar), 400 psi (28 bar) Standard Setting, E — 100 - 400 psi (7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 800 - 4500 psi (55 - 315 bar), 1000 psi (70 bar) Standard Setting
  • Seal material: N — Buna-N, V — Viton

Selection notes

  • Use only where a drain connection is impossible: over time it can weep oil or draw moisture into the spring chamber.
  • Suitable for load-holding duty.

Where it is used

Sequence functions where no drain line can be run.

Installation and seal kits

Valve hex 1 1/8 in. (28,6 mm); installation torque 45 - 50 lbf ft (61 - 68 Nm). Replacement seal kits — series 2: Buna: 990203007, Viton: 990203006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example SCEBLAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.

Installation

ParameterValue
Valve hex size1 1/8 in. (28,6 mm)
Installation torque45 - 50 lbf ft (61 - 68 Nm)
Seal kitsseries 2: Buna: 990203007, Viton: 990203006
Weight.60 lb (0,30 kg)

Configuration

ParameterValue
Control / adjustmentC — Tamper Resistant - Factory Set, L — Standard Screw Adjustment, K — Handknob
Seal materialN — Buna-N, V — Viton

Identification

ParameterValue
Valve functionAtmospherically Vented Direct-Acting Sequence Valve
Series (frame sizes)2
CavityT-5A

Performance

ParameterValue
Capacity30 gpm (120 L/min)
Max operating pressure5000 psi (350 bar)
Setting rangeA — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 300 - 1500 psi (20 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 2000 - 6000 psi (140 - 420 bar), 2000 psi (140 bar) Standard Setting, D — 200 - 800 psi (14 - 55 bar), 400 psi (28 bar) Standard Setting, E — 100 - 400 psi (7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 800 - 4500 psi (55 - 315 bar), 1000 psi (70 bar) Standard Setting
Max leakage10 drops/min. (0,7 cc/min)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations