Sun Hydraulics Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check — SCEB

Sun Hydraulics atmospherically vented direct-acting sequence valve: SCEB, series 2, 30 gpm (120 L/min), T-5A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Atmospherically Vented Direct-Acting Sequence Valve
- Capacity: 30 gpm (120 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-5A
- Valve function
- Atmospherically Vented Direct-Acting Sequence Valve
- Series (frame sizes)
- 2
- Cavity
- T-5A
Product description
A direct-acting sequence cartridge whose spring chamber is open to atmosphere instead of a drain port. It opens the second branch once inlet pressure passes the setting; the with-check version also lets oil return freely from port 2 to port 1.
Sizes and cavities
Sun Hydraulics builds this valve in 1 size. The series sets the cavity it screws into and its flow capacity:
- SCEB — series 2, T-5A cavity, 30 gpm (120 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 10 drops/min. (0,7 cc/min)
- Typical response time: 2 ms
- Check cracking pressure: 25 psi (1,7 bar)
Configuration options
The letters after the base model code choose these options (shown for SCEB; a size may add or drop a choice):
- Control: C — Tamper Resistant - Factory Set, L — Standard Screw Adjustment, K — Handknob
- Setting range: A — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 300 - 1500 psi (20 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 2000 - 6000 psi (140 - 420 bar), 2000 psi (140 bar) Standard Setting, D — 200 - 800 psi (14 - 55 bar), 400 psi (28 bar) Standard Setting, E — 100 - 400 psi (7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 800 - 4500 psi (55 - 315 bar), 1000 psi (70 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton
Selection notes
- Use only where a drain connection is impossible: over time it can weep oil or draw moisture into the spring chamber.
- Suitable for load-holding duty.
Where it is used
Sequence functions where no drain line can be run.
Installation and seal kits
Valve hex 1 1/8 in. (28,6 mm); installation torque 45 - 50 lbf ft (61 - 68 Nm). Replacement seal kits — series 2: Buna: 990203007, Viton: 990203006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example SCEBLAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 1 1/8 in. (28,6 mm) |
| Installation torque | 45 - 50 lbf ft (61 - 68 Nm) |
| Seal kits | series 2: Buna: 990203007, Viton: 990203006 |
| Weight | .60 lb (0,30 kg) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | C — Tamper Resistant - Factory Set, L — Standard Screw Adjustment, K — Handknob |
| Seal material | N — Buna-N, V — Viton |
Identification
| Parameter | Value |
|---|---|
| Valve function | Atmospherically Vented Direct-Acting Sequence Valve |
| Series (frame sizes) | 2 |
| Cavity | T-5A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 30 gpm (120 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 300 - 1500 psi (20 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 2000 - 6000 psi (140 - 420 bar), 2000 psi (140 bar) Standard Setting, D — 200 - 800 psi (14 - 55 bar), 400 psi (28 bar) Standard Setting, E — 100 - 400 psi (7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 800 - 4500 psi (55 - 315 bar), 1000 psi (70 bar) Standard Setting |
| Max leakage | 10 drops/min. (0,7 cc/min) |
Shipping & lead time
Sizes & part numbers
1 size- Sun Hydraulics part no.SCEB
- Series
- 2
- Cavity
- T-5A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check (SCEB) and what does it do?▾
How do I read the Sun model code for the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check (SCEB)?▾
What sizes and flow capacities does the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check come in?▾
What pressure and setting range does the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check have?▾
Which seal and material options does the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check come with?▾
How is the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check adjusted, and which control options are offered?▾
Which seal kit fits the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check (SCEB)?▾
Which cavity and installation torque does the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check need?▾
Where is the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check used?▾
How does the Sun SCEB valve differ from the Sun Atmospherically Referenced, Direct-Acting Sequence Valve Without Reverse Flow Check?▾
What does a sequence valve do on the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check?▾
Do you stock the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations