Sun Hydraulics Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity and Drain to Port 4 — RVCD8, RVED8, RVGD8, RVID8, Series 1 to 4

Sun Hydraulics relief main stage with integral T-8A pilot cavity: RVCD8, RVED8, RVGD8, RVID8, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-21A, T-22A, T-23A, T-24A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Relief Main Stage with Integral T-8A Pilot Cavity
- Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-21A, T-22A, T-23A, T-24A
- Valve function
- Relief Main Stage with Integral T-8A Pilot Cavity
- Series (frame sizes)
- 1 to 4
- Cavity
- T-21A, T-22A, T-23A, T-24A
Product description
A pilot-operated relief main stage with its own T-8A control cavity machined into the cartridge. Any T-8A pressure-control cartridge screwed into that cavity sets the relief pressure — a manual pilot relief, an electro-proportional pilot, or an air-controlled one — so the same main stage can be adjusted locally or controlled remotely.
Sizes and cavities
Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:
- RVCD8 — series 1, T-21A cavity, 15 gpm (60 L/min)
- RVED8 — series 2, T-22A cavity, 30 gpm (120 L/min)
- RVGD8 — series 3, T-23A cavity, 60 gpm (240 L/min)
- RVID8 — series 4, T-24A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Typical response time: 10 ms
Configuration options
The letters after the base model code choose these options (shown for RVCD8; a size may add or drop a choice):
- Setting range: D — 25 psi (1,7 bar), W — 100 psi (7 bar)
- Seal material: N — Buna-N, V — Viton, E — EPDM
Selection notes
- Supplied as the main stage; the T-8A pilot cartridge is chosen separately.
- The pilot cartridge's setting determines the pressure difference across the valve.
Where it is used
Building remotely or electronically controlled relief functions without a separate pilot body.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, EPDM: 990022014, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, EPDM: 990023014, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, Polyurethane: 990024002, Viton: 990024006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example RVCD8WN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Relief Main Stage with Integral T-8A Pilot Cavity |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-21A, T-22A, T-23A, T-24A |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, EPDM: 990022014, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, EPDM: 990023014, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, Polyurethane: 990024002, Viton: 990024006 |
| Weight | .40 lb (0,20 kg) to 3.10 lb (1,40 kg) |
Performance
| Parameter | Value |
|---|---|
| Capacity | 15 gpm to 120 gpm (60 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | D — 25 psi (1,7 bar), W — 100 psi (7 bar) |
Configuration
| Parameter | Value |
|---|---|
| Seal material | N — Buna-N, V — Viton, E — EPDM |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.RVCD8
- Series
- 1
- Cavity
- T-21A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVED8
- Series
- 2
- Cavity
- T-22A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVGD8
- Series
- 3
- Cavity
- T-23A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVID8
- Series
- 4
- Cavity
- T-24A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics RVCD8 cartridge valve and what does it do?▾
What does the Sun model code for the RVCD8 valve mean?▾
Which sizes and flows does the Sun RVCD8, RVED8, RVGD8 and others valve cover?▾
What is the maximum pressure of the Sun RVCD8, RVED8, RVGD8 and others valve?▾
What seals and coatings are offered on the Sun RVCD8, RVED8, RVGD8 and others valve?▾
How is the setting of the Sun Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity and Drain to Port 4 chosen?▾
Which seal kit do I need for the Sun RVCD8 cartridge?▾
How do I install the Sun RVCD8, RVED8, RVGD8 and others cartridge valve?▾
Where is the Sun Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity and Drain to Port 4 used?▾
How does the Sun RVCD8 valve differ from the Sun Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity?▾
What do I fit in the T-8A cavity on the Sun Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity and Drain to Port 4?▾
Do you stock the Sun Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity and Drain to Port 4?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations