Skip to content
SUN HYDRAULICSIH-SUN-PP-F8

Sun Hydraulics Pilot-Operated, Pressure Reducing/Relieving Main Stage with Drilled Piston Orifice and Integral T-8A Control Cavity — PPDF8, PPFF8, PPHF8, PPJF8, Series 1 to 4

Relief, Reducing & Sequence CartridgesEx-stock · delivery in 3 days
Sun Hydraulics PPDF8 reducing/relieving main stage with T-8A pilot cavity, series 1, T-11A cavity — dimension drawing
VIEW 01·Sun Hydraulics PPDF8 reducing/relieving main stage with T-8A pilot cavity, series 1, T-11A cavity — dimension drawing
1 / 3

Sun Hydraulics reducing/relieving main stage with T-8A pilot cavity: PPDF8, PPFF8, PPHF8, PPJF8, series 1 to 4, 10 gpm to 80 gpm (40 L/min to 320 L/min), T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Reducing/Relieving Main Stage with T-8A Pilot Cavity
  • Capacity: 10 gpm to 80 gpm (40 L/min to 320 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-11A, T-2A, T-17A, T-19A
Valve function
Reducing/Relieving Main Stage with T-8A Pilot Cavity
Series (frame sizes)
1 to 4
Cavity
T-11A, T-2A, T-17A, T-19A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A 3-way, normally open reducing/relieving main stage with an integral T-8A pilot cavity. The pilot cartridge fitted there sets the difference between the reduced pressure at port 1 and tank at port 3; the main stage carries the full flow both ways.

Sizes and cavities

Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:

  • PPDF8 — series 1, T-11A cavity, 10 gpm (40 L/min)
  • PPFF8 — series 2, T-2A cavity, 20 gpm (80 L/min)
  • PPHF8 — series 3, T-17A cavity, 40 gpm (160 L/min)
  • PPJF8 — series 4, T-19A cavity, 80 gpm (320 L/min)

Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)

Configuration options

The letters after the base model code choose these options (shown for PPDF8; a size may add or drop a choice):

  • Setting range: D — 25 psi (1,7 bar), W — 100 psi (7 bar)
  • Seal material: L — Extended Temp. Buna, N — Buna-N, V — Viton

Selection notes

  • The T-8A pilot cartridge is ordered separately.
  • Pressure at port 3 adds one-for-one to the setting; keep it under 3,000 psi (210 bar).
  • Variants add a port-4 drain, a drilled piston orifice or an open transition.

Where it is used

Remote or electro-proportional control of a reduced-pressure circuit from one cavity.

Installation and seal kits

Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example PPDF8WN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.

Identification

ParameterValue
Valve functionReducing/Relieving Main Stage with T-8A Pilot Cavity
Series (frame sizes)1 to 4
CavityT-11A, T-2A, T-17A, T-19A

Installation

ParameterValue
Valve hex size7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm)
Installation torque30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm)
Seal kitsseries 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006
Weight.30 lb (0,15 kg) to 3.10 lb (1,40 kg)

Performance

ParameterValue
Capacity10 gpm to 80 gpm (40 L/min to 320 L/min)
Max operating pressure5000 psi (350 bar)
Setting rangeD — 25 psi (1,7 bar), W — 100 psi (7 bar)

Configuration

ParameterValue
Seal materialL — Extended Temp. Buna, N — Buna-N, V — Viton

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

Also known as

The same part, in the designations used across European and Gulf trade catalogues.

de
Reduzierung
fr
réducteur
es
reductor
it
riduzione
RELATED · OFTEN PAIRED WITH

Engineers viewing this also looked at