How to choose
Size the link to the hook and to every leg
Start from the hook the link must hang on: the master link's inside length and width must let it seat freely in the hook bowl without binding. Then rate it for the total load of all legs, at the sling angle, in the same grade as the chain or fittings below it. For three- and four-leg slings use a master link assembly with intermediate links, not one large link. Cold shut and repair links are for chain repair and general duty, not overhead lifting. To quote, send the hook size, number of legs, WLL, grade and quantity.