Sun Hydraulics Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4 — RVCD, RVED, RVGD, RVID, Series 1 to 4

Sun Hydraulics ventable relief valve with drain to port 4: RVCD, RVED, RVGD, RVID, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-21A, T-22A, T-23A, T-24A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Ventable Relief Valve with Drain to Port 4
- Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-21A, T-22A, T-23A, T-24A
- Valve function
- Ventable Relief Valve with Drain to Port 4
- Series (frame sizes)
- 1 to 4
- Cavity
- T-21A, T-22A, T-23A, T-24A
Product description
A ventable, pilot-operated relief cartridge with a separate drain (port 4) for the pilot stage. As with other ventable reliefs, the vent port (port 3) allows unloading or remote control; the drain makes the setting insensitive to back-pressure at the tank port.
Sizes and cavities
Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:
- RVCD — series 1, T-21A cavity, 15 gpm (60 L/min)
- RVED — series 2, T-22A cavity, 30 gpm (120 L/min)
- RVGD — series 3, T-23A cavity, 60 gpm (240 L/min)
- RVID — series 4, T-24A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 2 in³/min.@1000 psi (30 cc/min.@70 bar), 3 in³/min.@1000 psi (50 cc/min.@70 bar), 4 in³/min.@1000 psi (65 cc/min.@70 bar), 5 in³/min.@1000 psi (80 cc/min.@70 bar)
- Typical response time: 10 ms
Configuration options
The letters after the base model code choose these options (shown for RVCD; a size may add or drop a choice):
- Control: C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment, Y — Tri-Grip Handknob, W — Hex Wrench Adjustment
- Setting range: A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 150 - 6000 psi (10,5 - 420 bar), 1000 psi (70 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 400 psi (28 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 1000 psi (70 bar) Standard Setting, H — 30 - 3000 psi (2 - 210 bar), 1000 psi (70 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton, E — EPDM
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /AP, the control must be C, L or Y; If the modifier is /LH, the control must be C or L; If the seal is E, the control must be C,K,L,W or Y.
Selection notes
- Drain port 4 must go to tank without restriction.
- Vent port 3 gives unloading or a remote setting.
Where it is used
Remote-controlled or unloading relief functions where the tank line carries back-pressure.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, EPDM: 990024014, Polyurethane: 990024002, Viton: 990024006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example RVCDLAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Ventable Relief Valve with Drain to Port 4 |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-21A, T-22A, T-23A, T-24A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 15 gpm to 120 gpm (60 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 150 - 6000 psi (10,5 - 420 bar), 1000 psi (70 bar) Standard Setting, D — 25 - 800 psi (1,7 - 55 bar), 400 psi (28 bar) Standard Setting, E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 1000 psi (70 bar) Standard Setting, H — 30 - 3000 psi (2 - 210 bar), 1000 psi (70 bar) Standa |
| Max leakage | 2 in³/min.@1000 psi (30 cc/min.@70 bar), 3 in³/min.@1000 psi (50 cc/min.@70 bar), 4 in³/min.@1000 psi (65 cc/min.@70 bar), 5 in³/min.@1000 psi (80 cc/min.@70 bar) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment, Y — Tri-Grip Handknob, W — Hex Wrench Adjustment |
| Seal material | N — Buna-N, V — Viton, E — EPDM |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, EPDM: 990024014, Polyurethane: 990024002, Viton: 990024006 |
| Weight | .40 lb (0,20 kg) to 3.10 lb (1,40 kg) |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.RVCD
- Series
- 1
- Cavity
- T-21A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVED
- Series
- 2
- Cavity
- T-22A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVGD
- Series
- 3
- Cavity
- T-23A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVID
- Series
- 4
- Cavity
- T-24A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4 (RVCD, RVED, RVGD and others) and what does it do?▾
How do I read the Sun model code for the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4 (RVCD, RVED, RVGD and others)?▾
What sizes and flow capacities does the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4 come in?▾
What pressure and setting range does the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4 have?▾
Which seal and material options does the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4 come with?▾
How is the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4 adjusted, and which control options are offered?▾
Which seal kit fits the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4 (RVCD, RVED, RVGD and others)?▾
Which cavity and installation torque does the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4 need?▾
Where is the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4 used?▾
How does the Sun RVCD valve differ from the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve?▾
Why have a separate drain on the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4?▾
Do you stock the Sun Ventable, Pilot-Operated, Balanced Piston Relief Valve with Drain to Port 4 in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations