Sun Hydraulics Pilot-Operated, Pressure Reducing/Relieving Main Stage with Integral T-8A Control Cavity, Drilled Piston Orifice, and Drain to Port 4 — PVDC8

Sun Hydraulics reducing/relieving main stage with T-8A pilot cavity: PVDC8, series 1, 10 gpm (40 L/min), T-21A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Reducing/Relieving Main Stage with T-8A Pilot Cavity
- Capacity: 10 gpm (40 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-21A
- Valve function
- Reducing/Relieving Main Stage with T-8A Pilot Cavity
- Series (frame sizes)
- 1
- Cavity
- T-21A
Product description
A 3-way, normally open reducing/relieving main stage with an integral T-8A pilot cavity. The pilot cartridge fitted there sets the difference between the reduced pressure at port 1 and tank at port 3; the main stage carries the full flow both ways.
Sizes and cavities
Sun Hydraulics builds this valve in 1 size. The series sets the cavity it screws into and its flow capacity:
- PVDC8 — series 1, T-21A cavity, 10 gpm (40 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
Configuration options
The letters after the base model code choose these options (shown for PVDC8; a size may add or drop a choice):
- Setting range: D — 25 psi (1,7 bar), W — 100 psi (7 bar)
- Seal material: N — Buna-N, V — Viton
Selection notes
- The T-8A pilot cartridge is ordered separately.
- Pressure at port 3 adds one-for-one to the setting; keep it under 3,000 psi (210 bar).
- Variants add a port-4 drain, a drilled piston orifice or an open transition.
Where it is used
Remote or electro-proportional control of a reduced-pressure circuit from one cavity.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm). Replacement seal kits — series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example PVDC8WN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Reducing/Relieving Main Stage with T-8A Pilot Cavity |
| Series (frame sizes) | 1 |
| Cavity | T-21A |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm) |
| Seal kits | series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006 |
| Weight | .30 lb (0,15 kg) |
Performance
| Parameter | Value |
|---|---|
| Capacity | 10 gpm (40 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | D — 25 psi (1,7 bar), W — 100 psi (7 bar) |
Configuration
| Parameter | Value |
|---|---|
| Seal material | N — Buna-N, V — Viton |
Shipping & lead time
Sizes & part numbers
1 size- Sun Hydraulics part no.PVDC8
- Series
- 1
- Cavity
- T-21A
- Capacity
- 10 gpm / 40 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics PVDC8 cartridge valve and what does it do?▾
What does the Sun model code for the PVDC8 valve mean?▾
Which sizes and flows does the Sun PVDC8 valve cover?▾
What is the maximum pressure of the Sun PVDC8 valve?▾
What seals and coatings are offered on the Sun PVDC8 valve?▾
How is the Sun PVDC8 valve adjusted?▾
Which seal kit do I need for the Sun PVDC8 cartridge?▾
How do I install the Sun PVDC8 cartridge valve?▾
Where is the Sun Pilot-Operated, Pressure Reducing/Relieving Main Stage with Integral T-8A Control Cavity, Drilled Piston Orifice, and Drain to Port 4 used?▾
How does the Sun PVDC8 valve differ from the Sun Pilot-Operated, Pressure Reducing/Relieving Main Stage with Integral T-8A Control Cavity and Drain to Port 4?▾
Does pressure in the tank line change the setting on the Sun PVDC8 valve?▾
Do you stock the Sun Pilot-Operated, Pressure Reducing/Relieving Main Stage with Integral T-8A Control Cavity, Drilled Piston Orifice, and Drain to Port 4?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
The same part, in the designations used across European and Gulf trade catalogues.
- de
- Reduzierung
- fr
- réducteur
- es
- reductor
- it
- riduzione