Skip to content
+971 52 2477942

Category

Oilfield Valves

Oilfield valves isolate, control and protect the flow of oil, gas and frac fluid from the wellhead to the process plant: gate, plug, ball, check, choke, relief and surface safety valves, rated in API 6A pressure classes or by hammer-union figure. Indus supplies them from Dubai in standard and sour service, including Cameron, WOM, TechnipFMC, SPM, Anson and Stream-Flo equipment, with DEMCO gate-valve repair parts and its own range.

153 SKUs7 brands

Choose the valve by its duty, then its connection

Gate valves give full-bore isolation on wellheads and manifolds; plug valves give fast quarter-turn isolation on frac and cement lines; chokes set the flow rate; check valves stop reverse flow; relief valves protect against overpressure; and surface safety valves shut the well in automatically. Then fix the end connection — API 6A flange, hammer-union figure or ASME flange — the pressure class and the service, standard or sour. For repair parts, send the make, model, size and pressure class from the nameplate.

API 6A, API 6D, API 16C and NACE MR0175

Wellhead, Christmas-tree and surface safety valves are covered by API 6A, pipeline valves by API 6D, and choke and kill valves by API 16C. Sour-service materials meet NACE MR0175 / ISO 15156. API 6A valves carry four further ratings: a product specification level (PSL 1 to 4), a performance requirement (PR1 or PR2), a temperature class and a material class. Each product page states the ones its maker publishes.

Delivery

Oilfield Valves across the Gulf

Ex-stock from Dubai, delivered within 3 working days in the UAE.

A valve is bought on two numbers — pressure class and material class — and neither changes at a border, which makes this one of the more straightforward things to source from abroad. We supply against them from Dubai with mill certificates and test records in the crate, so the receiving inspection has documents to check rather than a name to trust.

Beyond the Gulf

North America & Caribbean
the United States, Costa Rica, Guatemala
West & Central Africa
Nigeria, Chad, Gabon
CIS & Caucasus
Kazakhstan, Moldova, Uzbekistan

See every export destination

Showing 145–153 of 153 SKUs

Carbon steel needle valve, 1/2 in NPT, 10,000 psi sour service
IH-OFV-INST-NEEDLE-12-NPT-10K-SOUR-CAMERON-CS

Needle Valve, 1/2 in NPT, 10,000 psi, Sour Service, Carbon Steel Body, -50/+250°F

Cameron1/2 in1/2 in NPT Female
Category image · Oilfield Valves
IH-OFV-CHK-SWING-TE-3-1502FM-15K-STD-WOM

Swing Check Valve, Tee Body, 3 in × 1502 F×M, 15,000 psi, Standard Service

Worldwide Oilfield Machine15000 psi3 in 1502 Female Weco Union
Blue lubricated plug valve, 2 in × 1 in 1502 M×F reducing, 10,000 psi sour
IH-OFV-PLUG-LT-2X1-1502MF-10K-SOUR-SPM

Plug Valve, Lubricated (LT), Manual, 2 in × 1 in 1502 M×F (Reducing), 10,000 psi, Sour Service

SPM Oil & Gas10000 psi2 in × 1 in
Category image · Oilfield Valves
IH-OFV-BALL-3-1502FM-15K-STD-ANSON

Trunnion Ball Valve, 3 in × 1502 F×M, 15,000 psi, Standard Service

AnsonBall — Trunnion15K
Category image · Oilfield Valves
IH-OFV-INST-BLEED-12-NPT-10K-SOUR-INDUS

Bleed Valve, 1/2 in NPT, 10,000 psi, Sour Service, 316SS Body

Indus Hydraulics1/2 in NPT FemaleSour (NACE MR0175)
Blue lubricated plug valve with handwheel, 2 in × 1502 M×F, 15,000 psi
IH-OFV-PLUG-LT-2-1502MF-15K-STD-ANSON

Plug Valve, Lubricated (LT), Manual, 2 in × 1502 M×F, 15,000 psi, Standard Service

AnsonStandardPlug
Type R wafer check valve with flapper and lifting eye, 3-1/16 in × 15M
IH-OFV-CHK-TYPER-3116-15K-PSL3-STREAMFLO

Type R Wafer Check Valve, 3-1/16 in × 15M Flanged, 15,000 psi, API 6A PSL 3 PR1, EE-1.5

Stream-Flo Industries3-1/16 in15000 psi
Three red spring-loaded pressure relief valves, 3 in × 1502 M×F, 15,000 psi
IH-OFV-PRV-SPRING-3-1502MF-15K-STD-WOM

Pressure Relief Valve, Spring-Loaded, 3 in × 1502 M×F, 15,000 psi, Standard Service

Worldwide Oilfield Machine15000 psi15K
Category image · Oilfield Valves
IH-OFV-BALL-2-BW160-5K-SOUR-SPM

Floating Ball Valve, 2 in × Butt-Weld Schedule 160, 5,000 psi, Sour Service

SPM Oil & GasSour (NACE MR0175)Ball — Floating

Questions we get asked

About this range

01Gate valve or plug valve — which should I use?
A gate valve gives a full, straight bore and seals in both directions; it is multi-turn and slower to operate, and is the standard isolation valve on wellheads, Christmas trees and manifolds. A plug valve opens and closes in a quarter turn, is compact, and is used on frac, cementing and flowback lines where iron is rigged up and valves are cycled often. Lubricated plug valves need regular greasing to seal; non-lubricated designs do not. Neither should be used to throttle — that is a choke's job.
02How do I read an API 6A rating such as PSL 3, PR1, P+U, EE-1.5?
PSL 3 is the product specification level — the testing and documentation tier, from 1 to 4. PR1 is the performance requirement; PR2 adds cycle testing. P+U is the temperature class: P covers -20 to 180°F and U 0 to 250°F, so P+U spans -20 to 250°F. EE is the material class (AA to CC general service, CC being stainless for CO2-corrosive wells; DD to HH sour service, HH in corrosion-resistant alloy), and the number after a sour class is the maximum H2S partial pressure in psia that the materials are qualified for.
03What does bean size mean on a choke?
The bean is the orifice that restricts flow, and its size is quoted in 64ths of an inch: a 32/64 bean is a 1/2″ opening. A positive choke uses a fixed bean that is changed to change the rate; an adjustable choke has a variable opening, and its "max bean" is the largest opening its trim allows.
04What is a surface safety valve (SSV)?
A fail-closed, actuated gate valve on the wellhead or flowline that shuts the well in automatically when its control pressure is lost — on an emergency shutdown signal, a high or low pressure pilot, a fire or a manual trip. Its hydraulic or pneumatic actuator holds it open against a spring; remove the pressure and it closes. SSVs are covered by API 6A and are controlled from an ESD panel.
05Spring-loaded or pilot-operated relief valve?
A spring-loaded relief valve is direct-acting: the spring holds the seat shut until pressure overcomes it, which makes it simple and robust. A pilot-operated valve uses a small pilot to control a larger main valve, which keeps the seat tight closer to set pressure and suits high pressures and tight margins between operating and set pressure. Both are listed; choose by the set pressure, the relieving capacity needed and the fluid.
06Do you supply DEMCO gate valve repair parts?
Yes — gates, seats, seat inserts and seal kits for DEMCO DM gate valves. The DM 2000–5000 and DM 7500 families look alike but their parts do not interchange, so send the model from the nameplate, the size and the pressure rating, or the kit number, and we confirm the right parts before quoting.
07Can valves be supplied with third-party inspection or witnessed testing?
Valves ship with the manufacturer's test and material certification listed on each product page. Third-party inspection, witnessed hydrostatic or gas testing, a higher PSL or a particular certificate format can be arranged on request; put it on the RFQ, because it affects the price and the lead time.
08Which oilfield valve brands do you supply?
Indus supplies Cameron (SLB), WOM, TechnipFMC, SPM, Anson and Stream-Flo, and DEMCO gate valve repair parts and its own oilfield valves.