Skip to content

Hydraulic SAE Flanges

15 SKUs3 brands

Showing 1–15 of 15 SKUs

SAE weld-on butt weld flange, square four-bolt pad with raised butt-weld neck

Weld-on Butt Weld

Indus Hydraulicsflange-face1/2" to 5"
Inquire
SAE weld-in socket weld flange, forged steel with plain socket bore

Weld-in Socket Weld

Indus HydraulicsSAE J518 flange face (Code 61 / Code 62)flange-face
Inquire
SAE socket weld double flange, two-piece flange with socket weld bore and cap screws

Socket Weld Double Flange

Indus HydraulicsSocket weld for tube/pipe end (1/2" to 5")weld
Inquire
Set of black socket-head cap screws and spring washers for SAE flanges

Set of Bolts and Spring Washers

Indus HydraulicsSAE J429 Grade 5 / Grade 8 bolt set with spring washers, matching SAE J518 4-bolt pattern1/2" to 5"
Inquire
SAE blind flange, solid four-bolt steel plate for blanking a flange port

SAE Blind Flange

Indus Hydraulicsblind-flangeCode 61 up to 210 bar (3000 psi); Code 62 up to 415 bar (6000 psi)
Inquire
Black nitrile O-ring for SAE four-bolt hydraulic flange connections

O-Rings for SAE Hydraulic Flanges

Indus Hydraulics1/2" to 5"SAE J518 flange-face O-ring (Code 61 / Code 62 sizes 1/2" to 5")
Inquire
SAE double flange with NPT threaded port, two-piece flange with cap screws

NPT Threaded Double Flange

Indus Hydraulicsnpt-taperdouble-flange
Inquire
SAE four-bolt flange with NPT female threaded port, forged steel

NPT Threaded

Indus Hydraulics1/2" to 5"flange-face
Inquire
SAE double flange with BSP threaded port, two-piece flange with cap screws

BSP Threaded Double Flange

Indus Hydraulics1/2" to 5"Code 61 up to 210 bar (3000 psi); Code 62 up to 415 bar (6000 psi)
Inquire
SAE four-bolt flange with BSP female threaded port, single forged steel flange half

BSP Threaded

Indus Hydraulics1/2" to 5"flange
Inquire
Category image · Hoses & Fittings
Category image · Hoses & Fittings
Category image · Hoses & Fittings
Category image · Hoses & Fittings

Questions we get asked

About this range

01How do I tell a Code 61 flange from a Code 62?
Measure the bolt spacing and the flange thickness against the port. At the same nominal size, Code 62 uses wider bolt spacing and a thicker flange than Code 61. The port on the pump or valve decides which you need.
02Does the O-ring need replacing when the flange is remade?
Yes. The joint seals on the O-ring in the flange face; fit a new one each time and tighten the bolts evenly in a cross pattern so the flange seats square.