A pump that dead-heads against a closed valve, a plug in a treating line or a blocked separator outlet can raise pressure faster than any person can react. The relief valve is set below the weakest component’s rating and opens on its own. Choosing one means choosing the type, the set pressure, the end connections and the materials — and then making sure it is tested on schedule, because a relief valve that has never lifted is an assumption.
/01Spring-loaded or pilot-operated.
| Type | How it closes | How it opens | Typical use |
|---|---|---|---|
| Spring-loadedHighlighted | A spring on the disc, set by compression | Line pressure overcomes the spring | Treating iron, pumps, small vessels |
| Pilot-operated (pop) | Line pressure on a larger piston or dome area | Pilot vents the dome; main valve opens fully | Separators, process vessels, larger flows |
| Pilot-operated (modulating) | As above | Pilot opens the main valve in proportion to overpressure | Where full-lift relief would upset the process |
Emerson’s Anderson Greenwood range shows the split clearly: spring valves with fixed or adjustable blowdown (the pressure drop below set before the valve reseats), and pilot valves in both pop and modulating designs. Its Type 81P spring valve, built under ASME Section VIII / XIII, holds set pressure within ±3% above 70 psig (±2 psi at or below), with cracking between 92.5% and 103% of set. On gas, Emerson defines set pressure as 93% of the pressure at which the valve pops.
/02Union ends or flanges.
On frac and well-service lines the relief valve is part of the treating iron: 2″ or 3″ 1502 (15,000 psi) or 602 (6,000 psi) hammer-union ends, male × female, so it fits straight into the line. Plant and well-test valves use ASME RF or API 6B/6BX flanges. API 526 standardises flanged steel relief valves — orifice letters, flange ratings and dimensions — so a union-end valve is bought against the maker’s own rating, not API 526. Match the union figure number to the line (see hammer union figure numbers) and never mix 1502 and 602 parts.
/03Sour service and testing.
SLB’s API 6A guide defines sour service as exposure to enough H2S to crack materials by the mechanisms NACE MR0175 / ISO 15156 addresses, and gives the H2S partial pressure as ppm ÷ 1,000,000 × shut-in pressure. Carbon and low-alloy steels must be no harder than 22 HRC. Austenitic stainless is limited too — for general components, 60 °C at 100 kPa (15 psi) H2S partial pressure — so “316 for sour service” is only true within those limits.
On US offshore facilities BSEE requires pressure safety valves to be tested at least annually, either bench-tested or fitted so they can be tested in place with an external pressure source. Onshore operators set their own interval; record every test against the valve’s tag.
Common questions
- Spring-loaded or pilot-operated relief valve?
- Spring-loaded for treating iron, pumps and smaller vessels; pilot-operated where flow is large or the operating pressure runs close to set, as on separators.
- How accurate is a relief valve set pressure?
- It depends on the valve. Emerson gives ±3% of set pressure above 70 psig for its Type 81P spring valve.
- Is a 1502 relief valve an API 526 valve?
- No. API 526 covers flanged steel relief valves; hammer-union valves are bought against the maker’s rating.
- How often should relief valves be tested?
- BSEE requires annual testing on US offshore facilities. Elsewhere follow the operator’s procedure and record each test.
What we list
Spring-loaded and pilot-operated relief valves with union and flanged ends:
- Pressure Relief Valve, Pilot-Operated, 3 in × 300# RF, 740 psi, Sour Service
- Pressure Relief Valve, Pilot-Operated, 3 in × 600# RF, 1,480 psi, Sour Service
- Pressure Relief Valve, Spring-Loaded, 2 in × 150# RF, 285 psi, Standard Service
- Pressure Relief Valve, Spring-Loaded, 2 in × 1502 M×F, 10,000 psi, Sour Service
- Pressure Relief Valve, Spring-Loaded, 2 in × 1502 M×F, 15,000 psi, Sour Service
- Pressure Relief Valve, Spring-Loaded, 2 in × 1502 M×F, 15,000 psi, Standard Service
- Pressure Relief Valve, Spring-Loaded, 2 in × 602 M×F, 6,000 psi, Sour Service
- Pressure Relief Valve, Spring-Loaded, 3 in × 1502 M×F, 15,000 psi, Standard Service
- Pressure Relief Valve, Spring-Loaded, 3-1/8 in × 5M Flanged, 5,000 psi, Sour Service
Pressure relief valves
IH-OFV-PRV-SPRING-2-1502MF-15K-STD-SPMPressure Relief Valve, Spring-Loaded, 2 in × 1502 M×F, 15,000 psi, Standard ServiceSPM Oil & Gas
IH-OFV-PRV-SPRING-2-1502MF-10K-SOUR-CAMERONPressure Relief Valve, Spring-Loaded, 2 in × 1502 M×F, 10,000 psi, Sour ServiceCameron
IH-OFV-PRV-SPRING-2-602MF-6K-SOUR-ANSONPressure Relief Valve, Spring-Loaded, 2 in × 602 M×F, 6,000 psi, Sour ServiceAnson- IH-OFV-PRV-PILOT-3-600RF-1480-SOUR-FMCPressure Relief Valve, Pilot-Operated, 3 in × 600# RF, 1,480 psi, Sour ServiceFMC Technologies
IH-OFV-PRV-SPRING-318-5M-FLG-5K-SOUR-STREAMFLOPressure Relief Valve, Spring-Loaded, 3-1/8 in × 5M Flanged, 5,000 psi, Sour ServiceStream-Flo Industries- IH-OFV-PRV-SPRING-2-150RF-285-STD-INDUSPressure Relief Valve, Spring-Loaded, 2 in × 150# RF, 285 psi, Standard ServiceIndus Hydraulics