Every time the anchor is weighed, each link grinds against its neighbours and against the pockets of the cable lifter, and over years the bar wears thin where it bears. Strength falls with the square of the remaining diameter, so a little wear matters. That is why the classification societies set a limit, and why a surveyor will put calipers on your chain at every special survey.
/01Minimum mean diameter by size.
| Nominal diameter | Minimum mean diameter |
|---|---|
| 12.5 | 11.00 |
| 14 | 12.32 |
| 16 | 14.08 |
| 17.5 | 15.40 |
| 19 | 16.72 |
| 20.5 | 18.04 |
| 22 | 19.36 |
| 24 | 21.12 |
| 26 | 22.88 |
| 28 | 24.64 |
| 30 | 26.40 |
| 32 | 28.16 |
| 34 | 29.92 |
| 36 | 31.68 |
| 38 | 33.44 |
| 40 | 35.20 |
| 42 | 36.96 |
| 44 | 38.72 |
| 46 | 40.48 |
| 48 | 42.24 |
| 50 | 44.00 |
| 52 | 45.76 |
| 54 | 47.52 |
| 56 | 49.28 |
| 58 | 51.04 |
| 60 | 52.80 |
| 62 | 54.56 |
| 64 | 56.32 |
| 66 | 58.08 |
| 68 | 59.84 |
| 70 | 61.60 |
| 73 | 64.24 |
| 76 | 66.88 |
| 78 | 68.64 |
| 81 | 71.28 |
| 84 | 73.92 |
| 87 | 76.56 |
| 90 | 79.20 |
| 92 | 80.96 |
| 95 | 83.60 |
| 97 | 85.36 |
| 100 | 88.00 |
| 102 | 89.76 |
| 105 | 92.40 |
| 107 | 94.16 |
| 111 | 97.68 |
| 114 | 100.32 |
| 117 | 102.96 |
| 120 | 105.60 |
| 122 | 107.36 |
| 124 | 109.12 |
| 127 | 111.76 |
| 130 | 114.40 |
| 132 | 116.16 |
| 137 | 120.56 |
| 142 | 124.96 |
| 147 | 129.36 |
| 152 | 133.76 |
| 157 | 138.16 |
| 162 | 142.56 |
/02Measuring a worn link.
The limit is on the mean diameter, so a single reading is not enough. In general practice:
- Find the most worn part of the link — usually the inside of the crown, where it bears on the next link, and the areas that ride in the cable lifter pockets.
- Clean off scale and growth, then take two caliper readings across the bar at right angles to each other.
- Average them: that is the mean diameter to compare with the table.
- Measure several links along each length, concentrating on the shots that work hardest — the ones nearest the anchor and those that sit on the windlass at anchor.
The class surveyor decides how many links and where; record the readings by shot so the trend can be followed from survey to survey.
/03Other reasons to renew.
A length can be condemned before it reaches the wear limit. A surveyor will look for:
- cracks, especially at the flash-butt weld and around the stud;
- links that are bent, twisted or visibly stretched;
- studs that are loose, cracked or missing;
- deep pitting or gouges;
- joining shackles and swivels that are worn, distorted or seized, or Kenter shackles whose taper pins and lead plugs are missing.
The 5% elongation limit in a chain’s factory proof test is not an in-service limit — see anchor chain testing.
/04Renewing a length.
Worn chain is replaced by the 27.5 m length. Order the replacement to the same nominal diameter, grade and type, with a new Kenter shackle or joining shackle and, where the join needs them, end and enlarged links. The certificate for the new length goes into the ship’s file with the old ones. If a whole cable is near the limit, compare a full renewal with a higher grade at a smaller size — see equipment number.
Common questions
- How much wear is allowed on anchor chain?
- Generally 12% of the nominal diameter, measured as the mean diameter of the most worn part of the link.
- What is the minimum diameter for 76 mm anchor chain?
- 66.88 mm.
- Where does anchor chain wear most?
- Where links bear on each other at the crowns, and where they ride in the cable lifter, mostly in the shots nearest the anchor.
- Do I have to renew the whole cable?
- No. Worn or damaged lengths are replaced individually, to the same size and grade, with new joining shackles.
- Does the wear limit apply to mooring chain?
- Offshore mooring chain has its own inspection and wear criteria under its mooring integrity plan and the class rules; this page covers ship anchor chain.
Replacement lengths and joining parts
IH-LR-AC-SLACGU1U2Stud Link Anchor Chain — Grades U1, U2 and U3
IH-LR-AC-KSGU2U3Kenter Shackle — Grades U2 and U3
IH-LR-AC-JSDGU2U3Joining Shackle, D Type — Grades U2 and U3
IH-MR-AC-ENDEnd Link — Stud Link Anchor Chain, Grades U2 and U3
IH-MR-AC-ENLEnlarged Link — Stud Link Anchor Chain, Grades U2 and U3
IH-MR-AC-LPLLead Plug for Kenter and Joining Shackle Pins