4SP Four-Spiral Hydraulic Hose

Four-spiral high-pressure hose for heavy-duty hydraulic systems with sustained high working pressures. 3/8" – 2" (DN10 – DN51).
Key features
- Applicable Standard: EN 856 4SP
- Construction Type: 4-spiral
- Bore Size Range: 3/8" – 2" (DN10 – DN51)
- Max Working Pressure: 450 bar
- Min Burst Pressure: 1800 bar
- Min Operating Temperature: -40 °C
- Max Operating Temperature: 100 °C
- Reinforcement: Four alternating layers of high-tensile spiralled steel wire
- Applicable Standard
- EN 856 4SP
- Construction Type
- 4-spiral
- Bore Size Range
- 3/8" – 2" (DN10 – DN51)
- Max Working Pressure
- 450 bar
- Min Burst Pressure
- 1800 bar
- Min Operating Temperature
- -40 °C
Product description
The 4SP Four-Spiral Hydraulic Hose Four-spiral high-pressure hose for heavy-duty hydraulic systems with sustained high working pressures. Conforms to EN 856 4SP.
Construction
- Tube: Synthetic rubber (NBR), oil-resistant
- Reinforcement: Four alternating layers of high-tensile spiralled steel wire
- Cover: Synthetic rubber, abrasion- and weather-resistant, MSHA-accepted, wrapped
Performance
Working pressures up to 450 bar at the smallest bore, with a minimum burst of 1800 bar (safety factor 4:1). Continuous service from -40°C to 100°C, with the upper limit reduced for aggressive fluids — ask for a fluid compatibility chart if needed.
Applications
- Heavy construction equipment — wheel loaders, dozers, excavators
- Hydraulic presses and forging machinery
- High-pressure power units in industrial plants
Compliance
- EN 856 4SP
- MSHA-accepted cover
Also available in
The same EN 856 4SP grade is stocked in Eaton Winner and Parker Hannifin in addition to the Indus reference shown here. Tell us your brand preference on the RFQ and we will quote accordingly.
Companion grades
For ultra-high pressures see 4SH or 6-spiral R15. For uniform high pressure across all bores see R13.
Identification
| Parameter | Value |
|---|---|
| Applicable Standard | EN 856 4SP |
| Construction Type | 4-spiral |
Dimensions
| Parameter | Value |
|---|---|
| Bore Size Range | 3/8" – 2" (DN10 – DN51) |
| Min Bend Radius | 180–630 mm by bore (180 mm at -06, 630 mm at -32) |
| Outside Diameter Range | 20.1–66.3 mm (-06 to -32) |
Performance
| Parameter | Value |
|---|---|
| Max Working Pressure | 450 bar |
| Min Burst Pressure | 1800 bar |
| Safety Factor | 4:1 |
| Working Pressure Range | 450 bar at -06 down to 210 bar at -32 |
| Min Operating Temperature | -40 °C |
| Max Operating Temperature | 100 °C |
Construction
| Parameter | Value |
|---|---|
| Reinforcement | Four alternating layers of high-tensile spiralled steel wire |
| Tube (Inner) Material | Synthetic rubber (NBR), oil-resistant |
| Cover Material | Synthetic rubber, abrasion- and weather-resistant, MSHA-accepted |
| Cover Finish | wrapped |
Compliance
| Parameter | Value |
|---|---|
| Conductivity | non-conductive |
Commercial
| Parameter | Value |
|---|---|
| Sold By | per-metre |
Shipping & lead time
What is EN 856 4SP four-spiral hydraulic hose used for?▾
Which sizes is EN 856 4SP hose available in?▾
What is the working pressure of 4SP hose from -06 to -32?▾
What is the minimum bend radius of EN 856 4SP hose?▾
What fluids and temperature range is 4SP hose suitable for?▾
Which standard does Indus 4SP hose conform to?▾
4SP vs 4SH hose: which four-spiral hose do I need?▾
4SP vs SAE 100R12 hose: how do the ratings compare?▾
Which crimp fittings and ferrules fit 4SP spiral hose?▾
Why does 4SP hose fail at the fitting, and how is it prevented?▾
What country of origin is declared for Indus 4SP hose?▾
Does Indus keep EN 856 4SP hose in stock?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this part
Machine down
Excavator hose failure: which circuit went, and how to tell
Boom, arm, bucket, swing or travel — the symptom tells you which circuit failed before anything comes apart. How to read it, and how to identify the hose without the dealer part number.
3 min read
Failure analysis
It burst at the fitting, not mid-length: what that tells you
Where a hose failed is diagnostic. A burst within a hand’s width of the ferrule almost never means the hose was under-rated — it means something at that end was wrong, and replacing like for like will do it again.
5 min read
Failure analysis
The hose failure post-mortem: eleven questions that stop it recurring
Most hose failures get replaced, not investigated, so the same position fails again next quarter. This is the record that turns a replacement into a fix — eleven fields, five minutes, and no special equipment.