Parker GlobalCore 487 Series Hydraulic Hoses

Parker GlobalCore 487 Series Hydraulic Hoses: 9 part numbers.
Product description
Parker GlobalCore 487 Series Hydraulic Hoses: 9 part numbers.
Specification
- Type: Hydraulic Hose Fitting
- Material: Synthetic Rubber Inner Tube And Cover
- Part numbers: 9
Sizes and part numbers
The Sizes & Part Numbers tab lists every Parker part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Choosing the hose
Select hose on working pressure, bore, temperature and fluid. The working pressure in the size table is the maximum for continuous duty; burst pressure is a test figure, not a working limit. End fittings must be from the series the hose maker approves for that hose.
How to order
Quote the Parker part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Application Type | Petroleum Base Hydraulic Fluids And Lubricating Oils |
| Design | Half ISO Bend Reinforced With 2 Steel Wire Braids Sold In Box Package For Hydraulics, Lubrication Standard Cover |
| Function | Medium-Pressure Hydraulic Tubing/Tube/Hose |
| Main Function | Hose |
| Material | Synthetic Rubber Inner Tube And Cover |
Shipping & lead time
Sizes & part numbers
9 sizes- Parker Hannifin part no.487-4-BX
- Description
- Crimp Hose Fitting
- Parker Hannifin part no.487-10-BX
- Description
- Crimp Hose Fitting
- Parker Hannifin part no.487-16-BX
- Description
- Crimp Hose Fitting
- Parker Hannifin part no.487-24-BX
- Description
- Crimp Hose Fitting
- Parker Hannifin part no.487-6-BX
- Description
- Crimp Hose Fitting
- Parker Hannifin part no.487-8-BX
- Description
- Crimp Hose Fitting
- Parker Hannifin part no.487-12-BX
- Description
- Crimp Hose Fitting
- Parker Hannifin part no.487-20-BX
- Description
- Crimp Hose Fitting
Show all 9 sizesShow fewer sizes
- Parker Hannifin part no.487-32-BX
- Description
- Crimp Hose Fitting
Description — What this part number is, as the manufacturer lists it. Ask us for the dimension drawing if you need it stamped.
What is the Parker GlobalCore 487 Series Hydraulic Hoses used for?▾
Which sizes does the Parker GlobalCore 487 Series Hydraulic Hoses come in?▾
What does part number 487-6-BX of the Parker GlobalCore 487 Series Hydraulic Hoses cover?▾
What is the working pressure of the Parker GlobalCore 487 Series Hydraulic Hoses?▾
What temperatures and fluids suit the Parker GlobalCore 487 Series Hydraulic Hoses?▾
Which standard does the Parker GlobalCore 487 Series Hydraulic Hoses meet?▾
Which fittings and ferrules do I use on the Parker GlobalCore 487 Series Hydraulic Hoses?▾
How should I route the Parker GlobalCore 487 Series Hydraulic Hoses and what is the minimum bend radius?▾
What applications is the Parker GlobalCore 487 Series Hydraulic Hoses recommended for?▾
Parker GlobalCore 487 Series Hydraulic Hoses or Parker GlobalCore 487 Series Hydraulic Hoses, Super Tough: which should I choose?▾
Where does the Parker GlobalCore 487 Series Hydraulic Hoses come from and how is it shipped?▾
Do you stock the Parker GlobalCore 487 Series Hydraulic Hoses in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
The same part, in the designations used across European and Gulf trade catalogues.
- de
- Hammerverschraubung Typ 487
- fr
- union à marteau type 487
- es
- unión de martillo tipo 487
- it
- giunto a martello tipo 487
From the blog
Written about this range
Machine down
Detaching a hose on a modern machine: guards, clips and the ones that fight back
On a machine built in the last fifteen years, getting to the hose takes longer than changing it. Most of that time is spent undoing things nobody photographed.
5 min read
Procurement & export
Bulk hose by the metre, or finished assemblies?
Buying hose on a reel and crimping your own looks cheaper and sometimes is. The decision turns on whether you can state a crimp diameter and prove you hit it.
3 min read
Failure analysis
Cover blistering and pinholes: usually permeation, not a defect
A bubble under the cover looks like a manufacturing fault and normally is not. It is gas that got through the tube and could not get out through the cover — which tells you something specific about the fluid and the duty.
4 min read