Sun Hydraulics Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity, Before Check — HVCA8

Sun Hydraulics relief valve with integral check: HVCA8, series 1, 10 gpm (40 L/min), T-21A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Relief Valve with Integral Check
- Capacity: 10 gpm (40 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-21A
- Valve function
- Relief Valve with Integral Check
- Series (frame sizes)
- 1
- Cavity
- T-21A
Product description
A CavitySaver™ multi-function cartridge combining a relief valve with a check valve in one cavity. Flow passes from the inlet (port 2) through the check to the system port (port 1), while the relief protects the line by opening to tank (port 3).
Sizes and cavities
Sun Hydraulics builds this valve in 1 size. The series sets the cavity it screws into and its flow capacity:
- HVCA8 — series 1, T-21A cavity, 10 gpm (40 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 2 in³/min.@1000 psi (30 cc/min.@70 bar)
- Typical response time: 10 ms
- Check cracking pressure: 25 psi (1,7 bar)
Configuration options
The letters after the base model code choose these options (shown for HVCA8; a size may add or drop a choice):
- Seal material: N — Buna-N, V — Viton, E — EPDM
Selection notes
- Its flow path differs from Sun's standard relief cartridges, so it does not fit a standard relief manifold cavity.
- Before-check and after-check versions put the relief upstream or downstream of the check.
Where it is used
Pump outlet protection with a built-in check, saving a cavity and a valve in compact manifolds.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm). Replacement seal kits — series 1: Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example HVCA8DN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Performance
| Parameter | Value |
|---|---|
| Capacity | 10 gpm (40 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Max leakage | 2 in³/min.@1000 psi (30 cc/min.@70 bar) |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm) |
| Seal kits | series 1: Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006 |
Identification
| Parameter | Value |
|---|---|
| Valve function | Relief Valve with Integral Check |
| Series (frame sizes) | 1 |
| Cavity | T-21A |
Configuration
| Parameter | Value |
|---|---|
| Seal material | N — Buna-N, V — Viton, E — EPDM |
Shipping & lead time
Sizes & part numbers
1 size- Sun Hydraulics part no.HVCA8
- Series
- 1
- Cavity
- T-21A
- Capacity
- 10 gpm / 40 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity, Before Check (HVCA8) and what does it do?▾
What does the Sun model code for the HVCA8 valve mean?▾
Which sizes and flows does the Sun HVCA8 valve cover?▾
What pressure and setting range does the Sun Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity, Before Check have?▾
What seals and coatings are offered on the Sun HVCA8 valve?▾
How is the setting of the Sun Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity, Before Check chosen?▾
Which seal kit fits the Sun Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity, Before Check (HVCA8)?▾
How do I install the Sun HVCA8 cartridge valve?▾
Where is the Sun Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity, Before Check used?▾
How does the Sun HVCA8 valve differ from the Sun Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity?▾
Why combine the relief and the check on the Sun Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity, Before Check?▾
Do you stock the Sun Ventable, Pilot-Operated, Balanced Piston Relief Main Stage with Integral T-8A Control Cavity, Before Check in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations