Skip to content
SUN HYDRAULICSIH-SUN-HVCA

Sun Hydraulics Ventable, Pilot-Operated, Balanced Piston Relief Valve, Before Check — HVCA

Relief, Reducing & Sequence CartridgesEx-stock · delivery in 3 days
Sun Hydraulics HVCA relief valve with integral check, series 1, T-21A cavity — dimension drawing
VIEW 01·Sun Hydraulics HVCA relief valve with integral check, series 1, T-21A cavity — dimension drawing
1 / 3

Sun Hydraulics relief valve with integral check: HVCA, series 1, 10 gpm (40 L/min), T-21A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Relief Valve with Integral Check
  • Capacity: 10 gpm (40 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-21A
Valve function
Relief Valve with Integral Check
Series (frame sizes)
1
Cavity
T-21A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A CavitySaver™ multi-function cartridge combining a relief valve with a check valve in one cavity. Flow passes from the inlet (port 2) through the check to the system port (port 1), while the relief protects the line by opening to tank (port 3).

Sizes and cavities

Sun Hydraulics builds this valve in 1 size. The series sets the cavity it screws into and its flow capacity:

  • HVCA — series 1, T-21A cavity, 10 gpm (40 L/min)

Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)
  • Maximum leakage: 2 in³/min.@1000 psi (30 cc/min.@70 bar)
  • Typical response time: 10 ms
  • Check cracking pressure: 25 psi (1,7 bar)

Configuration options

The letters after the base model code choose these options (shown for HVCA; a size may add or drop a choice):

  • Control: C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment
  • Setting range: A — 75 - 3000 psi (5 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 75 - 1500 psi (5 - 105 bar), 1000 psi (70 bar) Standard Setting, D — 75 - 800 psi (5 - 55 bar), 400 psi (28 bar) Standard Setting, W — 75 - 4500 psi (5 - 315 bar), 1000 psi (70 bar) Standard Setting
  • Seal material: N — Buna-N, V — Viton

Selection notes

  • Its flow path differs from Sun's standard relief cartridges, so it does not fit a standard relief manifold cavity.
  • Before-check and after-check versions put the relief upstream or downstream of the check.

Where it is used

Pump outlet protection with a built-in check, saving a cavity and a valve in compact manifolds.

Installation and seal kits

Valve hex 7/8 in. (22,2 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm). Replacement seal kits — series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example HVCALAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.

Installation

ParameterValue
Valve hex size7/8 in. (22,2 mm)
Installation torque30 - 35 lbf ft (41 - 47 Nm)
Seal kitsseries 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006
Weight.35 lb (0,15 kg)

Configuration

ParameterValue
Control / adjustmentC — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment
Seal materialN — Buna-N, V — Viton

Identification

ParameterValue
Valve functionRelief Valve with Integral Check
Series (frame sizes)1
CavityT-21A

Performance

ParameterValue
Capacity10 gpm (40 L/min)
Max operating pressure5000 psi (350 bar)
Setting rangeA — 75 - 3000 psi (5 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 75 - 1500 psi (5 - 105 bar), 1000 psi (70 bar) Standard Setting, D — 75 - 800 psi (5 - 55 bar), 400 psi (28 bar) Standard Setting, W — 75 - 4500 psi (5 - 315 bar), 1000 psi (70 bar) Standard Setting
Max leakage2 in³/min.@1000 psi (30 cc/min.@70 bar)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

RELATED · OFTEN PAIRED WITH

Engineers viewing this also looked at