MannTek DAC Dust Caps and Dust Plugs (ISO 45) — 2-1/2"

Dust caps and dust plugs for MannTek DAC dry aviation couplings, 2-1/2" ISO 45: aluminium or PE, each on a steel tether cable, to keep dirt and water off the coupling faces. From Indus Hydraulics, authorised MannTek distributor, UAE.
Key features
- Coupling Family: Dry Aviation Coupling
- Coupling Type / Variant: Closures: dust cap, dust plug
- End A Configuration: 2-1/2" DAC interface to ISO 45 / STANAG 3105
- Size Range: 2-1/2" (DN 65, socket Ø 105 mm)
- Coupling Family
- Dry Aviation Coupling
- Coupling Type / Variant
- Closures: dust cap, dust plug
- End A Configuration
- 2-1/2" DAC interface to ISO 45 / STANAG 3105
- Size Range
- 2-1/2" (DN 65, socket Ø 105 mm)
Product description
An aviation fuel coupling that is left open picks up dust, sand and water on its sealing faces, and in jet fuel service that is contamination as well as wear. MannTek makes a dust cap and a dust plug for the DAC so both halves can be closed whenever the hose is not connected. Each is tethered on a steel cable, so it stays with the coupling instead of being put down on the ground.
The four closures
- Dust cap, aluminium (MannTek K300A1101)
- Dust cap, PE (polyethylene composite, MannTek K300A2201)
- Dust plug, aluminium, with T-handle (MannTek I300A1101)
- Dust plug, PE, with T-handle (MannTek I300A2201)
MannTek gives -20 °C as the lowest operating temperature of the PE versions. All four are made for the 2-1/2" (DN 65, socket Ø 105 mm) DAC interface to ISO 45, MS24484 and STANAG 3105, the only DAC size.
Which one goes where
MannTek's designation key lists K as a dust cap and I as a dust plug for ISO 45 couplings. Tell us which half you need to close, tank unit or hose unit, and we will confirm the matching closure with the quotation.
Related
The DAC tank unit and hose unit are listed separately, and MannTek also makes adapters between DDC (STANAG 3756) and DAC (STANAG 3105) couplings.
Indus Hydraulics is an authorised MannTek distributor in the UAE and supplies MannTek couplings direct from MannTek in Sweden.
How to order
Send the size, the MannTek order code or the type and material from the size table. We confirm the MannTek order code, price and lead time with the quotation.
Identification
| Parameter | Value |
|---|---|
| Coupling Family | Dry Aviation Coupling |
| Coupling Type / Variant | Closures: dust cap, dust plug |
| Notes | MannTek order codes K300A1101, K300A2201, I300A1101, I300A2201. |
| Manufacturer | MannTek (Mann Teknik AB), Mariestad, Sweden |
Configuration
| Parameter | Value |
|---|---|
| End A Configuration | 2-1/2" DAC interface to ISO 45 / STANAG 3105 |
Dimensions
| Parameter | Value |
|---|---|
| Size Range | 2-1/2" (DN 65, socket Ø 105 mm) |
Construction
| Parameter | Value |
|---|---|
| Materials Available | Aluminium or PE (polyethylene composite) |
Compliance
| Parameter | Value |
|---|---|
| Applicable Standards | For couplings to ISO 45, MS24484, STANAG 3105 |
Performance
| Parameter | Value |
|---|---|
| Lowest operating temperature | -20 °C for the PE versions (MannTek) |
Shipping & lead time
Sizes & part numbers
4 sizes- Indus part no.IH-MNT-DAC-CAP-AL-065
- Description
- Aluminium, tethered on a steel cable. MannTek order code K300A1101
- Type
- Dust cap
- Body size
- Ø 105 mm
- Nominal size
- 2-1/2" (DN 65)
- Indus part no.IH-MNT-DAC-CAP-PE-065
- Description
- PE (polyethylene composite), tethered on a steel cable; lowest operating temperature -20 °C. MannTek order code K300A2201
- Type
- Dust cap
- Body size
- Ø 105 mm
- Nominal size
- 2-1/2" (DN 65)
- Indus part no.IH-MNT-DAC-PLUG-AL-065
- Description
- Aluminium with T-handle, tethered on a steel cable. MannTek order code I300A1101
- Type
- Dust plug
- Body size
- Ø 105 mm
- Nominal size
- 2-1/2" (DN 65)
- Indus part no.IH-MNT-DAC-PLUG-PE-065
- Description
- PE (polyethylene composite) with T-handle, tethered; lowest operating temperature -20 °C. MannTek order code I300A2201
- Type
- Dust plug
- Body size
- Ø 105 mm
- Nominal size
- 2-1/2" (DN 65)
Description — What this part number is, as the manufacturer lists it. Type — Which part of the coupling this is: coupler (female half), nipple (male half), complete set, dust cap or adapter. Body size — Nominal body size of the coupling, which sets which halves mate. Ask us for the dimension drawing if you need it stamped.
What is the MannTek DAC Dust Caps and Dust Plugs (ISO 45) and what is it used for?▾
What part numbers does the MannTek DAC Dust Caps and Dust Plugs (ISO 45) come in, for example IH-MNT-DAC-CAP-AL-065?▾
What sizes does the MannTek DAC Dust Caps and Dust Plugs (ISO 45) come in?▾
What working pressure is the MannTek DAC Dust Caps and Dust Plugs (ISO 45) rated for?▾
What is the MannTek DAC Dust Caps and Dust Plugs (ISO 45) made from?▾
What standards does the MannTek DAC Dust Caps and Dust Plugs (ISO 45) conform to?▾
What does the MannTek DAC Dust Caps and Dust Plugs (ISO 45) connect to?▾
How does the MannTek DAC Dust Caps and Dust Plugs (ISO 45) compare with a camlock for fluid transfer?▾
Where is the MannTek DAC Dust Caps and Dust Plugs (ISO 45) used?▾
What is the difference between the dust cap and the dust plug on the MannTek DAC Dust Caps and Dust Plugs (ISO 45)?▾
How does the MannTek DAC Dust Caps and Dust Plugs (ISO 45) differ from the MannTek DDC Dust Caps, Dust Plugs and Pressure Caps — 1" to?▾
Do you stock the MannTek DAC Dust Caps and Dust Plugs (ISO 45) in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Industrial hose
Dry disconnect vs camlock couplings: when the spill on disconnect matters
A camlock is an open coupling: part it under a full hose and the contents come out. A dry disconnect has a valve in each half that closes before the halves separate. How the two compare, which duties justify a dry disconnect, and what changing over involves.
5 min read
Industrial hose
LPG transfer couplings: dry gas couplings, EN 13175 and replacing open ACME
Open ACME couplings vent LPG every time a bobtail or tanker hose is disconnected. A dry gas coupling closes both halves before they part. What a dry gas coupling is, the standards it is built to, sizes by duty, and how to fit one to existing ACME connections.
3 min read
Industrial hose
Tanker loading and vapour recovery hose: reeling hose, composite and dry disconnects
A fuel tanker uses three different hoses and a coupling that must not drip. What a reeling hose is built for, why vapour recovery is composite, and when a dry disconnect earns its price.
4 min read








