Sun Hydraulics Bi-Directional, Direct-Acting Relief Valve — RBDA, RBFA, RBUA, RBUY, Series 1, 2, 1C

Sun Hydraulics bi-directional direct-acting relief valve: RBDA, RBFA, RBUA, RBUY, series 1, 2, 1C, 20 gpm to 30 gpm (80 L/min to 120 L/min), T-10A, SC-10-02, T-3A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Bi-Directional Direct-Acting Relief Valve
- Capacity: 20 gpm to 30 gpm (80 L/min to 120 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-10A, SC-10-02, T-3A
- Valve function
- Bi-Directional Direct-Acting Relief Valve
- Series (frame sizes)
- 1, 2, 1C
- Cavity
- T-10A, SC-10-02, T-3A
Product description
A direct-acting relief cartridge that limits the pressure difference between its two ports in either direction. When the differential exceeds the setting it opens and throttles flow, whichever port is higher — so one cartridge protects both sides of a motor or cylinder.
Sizes and cavities
Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:
- RBDA — series 1, T-10A cavity, 25 gpm (95 L/min)
- RBUA — series 1C, SC-10-02 cavity, 20 gpm (80 L/min), common cavity
- RBUY — series 1C, SC-10-02 cavity, 20 gpm (80 L/min), common cavity
- RBFA — series 2, T-3A cavity, 30 gpm (120 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 10 drops/min. (0,7 cc/min), 30 drops/min. (30 drops/min)
- Typical response time: 2 ms
- Reseat: >85% of setting, >80% of setting
Configuration options
The letters after the base model code choose these options (shown for RBDA; a size may add or drop a choice):
- Control: C — Tamper Resistant - Factory Set, L — Standard Screw Adjustment
- Setting range: A — 1200 - 3000 psi (85-210 bar), 1500 psi (105 bar) Standard Setting, W — 3000 - 5000 psi (210 - 350 bar), 4000 psi (280 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton
Selection notes
- Rated capacity differs by direction — see the size table and data.
- Modulates inside the cartridge, which limits cavitation noise and erosion.
Where it is used
Cross-port relief on hydraulic motors and double-acting cylinders, and relief in common-cavity manifolds.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm), 25 mm, 1 1/8 in. (28,6 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 23 - 26 lbf ft (31 - 35 Nm), 45 - 50 lbf ft (61 - 68 Nm). Replacement seal kits — series 1: Buna: 990310007, Viton: 990310006; series 1C: Buna: 99C102007, Viton: 99C102006; series 2: Buna: 990303007, Polyurethane: 990303002, Viton: 990303006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example RBDALAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 25 mm, 1 1/8 in. (28,6 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 23 - 26 lbf ft (31 - 35 Nm), 45 - 50 lbf ft (61 - 68 Nm) |
| Seal kits | series 1: Buna: 990310007, Viton: 990310006; series 1C: Buna: 99C102007, Viton: 99C102006; series 2: Buna: 990303007, Polyurethane: 990303002, Viton: 990303006 |
| Weight | .40 lb (0,20 kg) to .62 lb |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | C — Tamper Resistant - Factory Set, L — Standard Screw Adjustment |
| Seal material | N — Buna-N, V — Viton |
Identification
| Parameter | Value |
|---|---|
| Valve function | Bi-Directional Direct-Acting Relief Valve |
| Series (frame sizes) | 1, 2, 1C |
| Cavity | T-10A, SC-10-02, T-3A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 20 gpm to 30 gpm (80 L/min to 120 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 1200 - 3000 psi (85-210 bar), 1500 psi (105 bar) Standard Setting, W — 3000 - 5000 psi (210 - 350 bar), 4000 psi (280 bar) Standard Setting |
| Max leakage | 10 drops/min. (0,7 cc/min), 30 drops/min. (30 drops/min) |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.RBDA
- Description
- Standard
- Series
- 1
- Cavity
- T-10A
- Capacity
- 25 gpm / 95 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RBUA
- Description
- Common cavity
- Series
- 1C
- Cavity
- SC-10-02
- Capacity
- 20 gpm / 80 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RBUY
- Description
- Common cavity
- Series
- 1C
- Cavity
- SC-10-02
- Capacity
- 20 gpm / 80 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RBFA
- Description
- Standard
- Series
- 2
- Cavity
- T-3A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
Description — What this part number is, as the manufacturer lists it. Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Bi-Directional, Direct-Acting Relief Valve (RBDA, RBUA, RBUY and others) and what does it do?▾
How do I read the Sun model code for the Sun Bi-Directional, Direct-Acting Relief Valve (RBDA, RBUA, RBUY and others)?▾
What sizes and flow capacities does the Sun Bi-Directional, Direct-Acting Relief Valve come in?▾
What pressure and setting range does the Sun Bi-Directional, Direct-Acting Relief Valve have?▾
Which seal and material options does the Sun Bi-Directional, Direct-Acting Relief Valve come with?▾
How is the Sun Bi-Directional, Direct-Acting Relief Valve adjusted, and which control options are offered?▾
Which seal kit fits the Sun Bi-Directional, Direct-Acting Relief Valve (RBDA, RBUA, RBUY and others)?▾
Which cavity and installation torque does the Sun Bi-Directional, Direct-Acting Relief Valve need?▾
Where is the Sun Bi-Directional, Direct-Acting Relief Valve used?▾
How does the Sun Bi-Directional, Direct-Acting Relief Valve differ from the Sun Direct-Acting Relief Valve?▾
Why use a bi-directional relief instead of two relief valves on the Sun Bi-Directional, Direct-Acting Relief Valve?▾
Do you stock the Sun Bi-Directional, Direct-Acting Relief Valve in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations