Sun Hydraulics Direct-Acting Relief Valve — RDBA to RDUA, Series 0, 1, 2, 3, 4, 1C

Sun Hydraulics direct-acting relief valve: RDBA to RDUA, series 0, 1, 2, 3, 4, 1C, 10 gpm to 200 gpm (40 L/min to 760 L/min), T-162A, T-10A, SC-10-02, T-3A, T-16A, T-18A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Direct-Acting Relief Valve
- Capacity: 10 gpm to 200 gpm (40 L/min to 760 L/min)
- Max operating pressure: 5000 psi (350 bar), 6000 psi (420 bar)
- Cavity: T-162A, T-10A, SC-10-02, T-3A, T-16A, T-18A
- Valve function
- Direct-Acting Relief Valve
- Series (frame sizes)
- 0, 1, 2, 3, 4, 1C
- Cavity
- T-162A, T-10A, SC-10-02, T-3A, T-16A, T-18A
Product description
A normally closed, direct-acting relief cartridge that limits pressure. When pressure at port 1 reaches the setting it begins to open to tank at port 2, throttling flow to stop the pressure climbing further. With a single moving poppet it reacts in a few milliseconds, runs smooth and quiet, is tolerant of dirt and silting and is practically leak-free.
Sizes and cavities
Sun Hydraulics builds this valve in 6 sizes. The series sets the cavity it screws into and its flow capacity:
- RDBA — series 0, T-162A cavity, 12 gpm (45 L/min), 0-series
- RDDA — series 1, T-10A cavity, 25 gpm (95 L/min)
- RDUA — series 1C, SC-10-02 cavity, 10 gpm (40 L/min), 6000 psi (420 bar), common cavity
- RDFA — series 2, T-3A cavity, 50 gpm (200 L/min)
- RDHA — series 3, T-16A cavity, 100 gpm (380 L/min)
- RDJA — series 4, T-18A cavity, 200 gpm (760 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar), 6000 psi (420 bar)
- Maximum leakage: 10 drops/min. (0,7 cc/min)
- Typical response time: 2 ms
- Reseat: >85% of crack setting, >90% of setting
Configuration options
The letters after the base model code choose these options (shown for RDDA; a size may add or drop a choice):
- Control: L — Standard Screw Adjustment, C — Tamper Resistant - Factory Set, Y — Tri-Grip Handknob, F — Hex Head Screw with Locknut, J — Capped Screw Adjustment, K — Handknob, M — Capped Screw Adjustment with Lockwire Holes, Q — Capped and Lockwired, R — Capped Screw Adjustment, W — Hex Wrench Adjustment
- Setting range: A — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, W — 800 - 4500 psi (55 - 315 bar), 1000 psi (70 bar) Standard Setting, B — 300 - 1500 psi (20 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 1000 - 6000 psi (70 - 420 bar), 1000 psi (70 bar) Standard Setting, D — 200 - 800 psi (14 - 55 bar), 400 psi (28 bar) Standard Setting, E — 100 - 400 psi (7 - 28 bar), 200 psi (14 bar) Standard Setting, S — 50 - 200 psi (3,5 - 14 bar), 100 psi (7 bar) Standard Setting
- Seal material: N — Buna-N, L — Buna (low temp), V — Viton, E — EPDM
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: A modifier is required on control R; If the control is F, the range must be A; If the control is K, the range must be B,D,E or S; If the control is Y, the range must be B,D,E or S; If the modifier is /AP, the control must be C, L, Q, R or Y; If the modifier is /LH, the control must be C or L; If the seal is E, the control must be C,J,K,L,M,Q,W or Y.
Selection notes
- Accepts full pressure at port 2, so it suits cross-port relief circuits.
- Sun's 2-port relief cartridges of one frame size share one cavity and flow path.
Where it is used
Pump and system protection, shock and transient relief, cross-port relief on motors, and thermal relief on trapped volumes.
Installation and seal kits
Valve hex 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 24 mm, 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 42 - 46 lbf ft (57 - 62 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 0: Buna: 990162007, EPDM: 990162014, Polyurethane: 990162002, Viton: 990162006; series 1: Buna: 990310007, EPDM: 990310014, Viton: 990310006; series 2: Buna: 990303007, EPDM: 990303014, Polyurethane: 990303002, Viton: 990303006; series 3: Buna: 990316007, Viton: 990316006; series 4: Buna: 990318007, EPDM: 990318014, Viton: 990318006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example RDDALAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Direct-Acting Relief Valve |
| Series (frame sizes) | 0, 1, 2, 3, 4, 1C |
| Cavity | T-162A, T-10A, SC-10-02, T-3A, T-16A, T-18A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 10 gpm to 200 gpm (40 L/min to 760 L/min) |
| Max operating pressure | 5000 psi (350 bar), 6000 psi (420 bar) |
| Setting range | A — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, W — 800 - 4500 psi (55 - 315 bar), 1000 psi (70 bar) Standard Setting, B — 300 - 1500 psi (20 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 1000 - 6000 psi (70 - 420 bar), 1000 psi (70 bar) Standard Setting, D — 200 - 800 psi (14 - 55 bar), 400 psi (28 bar) Standard Setting, E — 100 - 400 psi (7 - 28 bar), 200 psi (14 bar) Standard Setting, S — 50 - 200 psi (3,5 - 14 bar), 100 psi (7 bar) Standard Se |
| Max leakage | 10 drops/min. (0,7 cc/min) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | L — Standard Screw Adjustment, C — Tamper Resistant - Factory Set, Y — Tri-Grip Handknob, F — Hex Head Screw with Locknut, J — Capped Screw Adjustment, K — Handknob, M — Capped Screw Adjustment with Lockwire Holes, Q — Capped and Lockwired, R — Capped Screw Adjustment, W — Hex Wrench Adjustment |
| Seal material | N — Buna-N, L — Buna (low temp), V — Viton, E — EPDM |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 24 mm, 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 42 - 46 lbf ft (57 - 62 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 0: Buna: 990162007, EPDM: 990162014, Polyurethane: 990162002, Viton: 990162006; series 1: Buna: 990310007, EPDM: 990310014, Viton: 990310006; series 2: Buna: 990303007, EPDM: 990303014, Polyurethane: 990303002, Viton: 990303006; series 3: Buna: 990316007, Viton: 990316006; series 4: Buna: 990318007, EPDM: 990318014, Viton: 990318006 |
| Weight | .20 lb (0,10 kg) to 3.30 lb (1,50 kg) |
Shipping & lead time
Sizes & part numbers
6 sizes- Sun Hydraulics part no.RDBA
- Description
- 0-Series
- Series
- 0
- Cavity
- T-162A
- Capacity
- 12 gpm / 45 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RDDA
- Description
- Standard
- Series
- 1
- Cavity
- T-10A
- Capacity
- 25 gpm / 95 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RDUA
- Description
- 6000 psi (420 bar), Common cavity
- Series
- 1C
- Cavity
- SC-10-02
- Capacity
- 10 gpm / 40 L/min
- Max pressure
- 6000 psi / 420 bar
- Sun Hydraulics part no.RDFA
- Description
- Standard
- Series
- 2
- Cavity
- T-3A
- Capacity
- 50 gpm / 200 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RDHA
- Description
- Standard
- Series
- 3
- Cavity
- T-16A
- Capacity
- 100 gpm / 380 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RDJA
- Description
- Standard
- Series
- 4
- Cavity
- T-18A
- Capacity
- 200 gpm / 760 L/min
- Max pressure
- 5000 psi / 350 bar
Description — What this part number is, as the manufacturer lists it. Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Direct-Acting Relief Valve (RDBA, RDDA, RDUA and others) and what does it do?▾
How do I read the Sun model code for the Sun Direct-Acting Relief Valve (RDBA, RDDA, RDUA and others)?▾
What sizes and flow capacities does the Sun Direct-Acting Relief Valve come in?▾
What pressure and setting range does the Sun Direct-Acting Relief Valve have?▾
Which seal and material options does the Sun Direct-Acting Relief Valve come with?▾
How is the Sun Direct-Acting Relief Valve adjusted, and which control options are offered?▾
Which seal kit fits the Sun Direct-Acting Relief Valve (RDBA, RDDA, RDUA and others)?▾
Which cavity and installation torque does the Sun Direct-Acting Relief Valve need?▾
Where is the Sun Direct-Acting Relief Valve used?▾
How does the Sun Direct-Acting Relief Valve differ from the Sun Bi-Directional, Direct-Acting Relief Valve?▾
Can the Sun Direct-Acting Relief Valve be used as a cross-port relief?▾
Do you stock the Sun Direct-Acting Relief Valve in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations