Sun Hydraulics Normally Open, Modulating Element with Integral T-8A Control Cavity and Pilot Source from Port 1 — LPJA8

Sun Hydraulics normally open modulating element with pilot source: LPJA8, series 4, 120 gpm (480 L/min), T-19A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Normally Open Modulating Element with Pilot Source
- Capacity: 120 gpm (480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-19A
- Valve function
- Normally Open Modulating Element with Pilot Source
- Series (frame sizes)
- 4
- Cavity
- T-19A
Product description
A normally open modulating element with an internal orifice from port 1 to port 3, used as the main stage of a reducing valve controlled by a pilot relief or pilot solenoid valve. The T-8A version carries its own pilot cavity.
Sizes and cavities
Sun Hydraulics builds this valve in 1 size. The series sets the cavity it screws into and its flow capacity:
- LPJA8 — series 4, T-19A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
Configuration options
The letters after the base model code choose these options (shown for LPJA8; a size may add or drop a choice):
- Seal material: N — Buna-N, V — Viton, E — EPDM
Selection notes
- Fit the main stage first, then the T-8A pilot, each to its own torque.
Where it is used
High-flow remotely or electronically controlled reducing functions.
Installation and seal kits
Valve hex 1 5/8 in. (41,3 mm); installation torque 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example LPJA8DN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Performance
| Parameter | Value |
|---|---|
| Capacity | 120 gpm (480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
Identification
| Parameter | Value |
|---|---|
| Valve function | Normally Open Modulating Element with Pilot Source |
| Series (frame sizes) | 4 |
| Cavity | T-19A |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 1 5/8 in. (41,3 mm) |
| Installation torque | 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006 |
Configuration
| Parameter | Value |
|---|---|
| Seal material | N — Buna-N, V — Viton, E — EPDM |
Shipping & lead time
Sizes & part numbers
1 size- Sun Hydraulics part no.LPJA8
- Series
- 4
- Cavity
- T-19A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics LPJA8 normally open modulating element with pilot source used for?▾
Which sizes and versions does the Sun Hydraulics LPJA8 normally open modulating element with pilot source come in?▾
How do I read the Sun Hydraulics model code LPJA8DN for the LPJA8 normally open modulating element with pilot source?▾
What is the maximum operating pressure of the Sun Hydraulics LPJA8 normally open modulating element with pilot source?▾
What flow capacity does the LPJA8 normally open modulating element with pilot source have?▾
Which seal materials and body finishes does the Sun Hydraulics LPJA8 normally open modulating element with pilot source come with?▾
Which cavity does the Sun Hydraulics LPJA8 normally open modulating element with pilot source fit?▾
Which seal kit fits the Sun Hydraulics LPJA8 normally open modulating element with pilot source?▾
How is the Sun Hydraulics LPJA8 normally open modulating element with pilot source installed?▾
Where is the Sun Hydraulics LPJA8 normally open modulating element with pilot source used?▾
Sun Hydraulics LPJA8 or LPBA, LPDA, LPFA, LPHA, LPJA: what is the difference?▾
Do you stock the Sun Hydraulics LPJA8 in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations