Sun Hydraulics Bypass/Restrictive, Priority Modulating Element — LHDA, LHFA, LHHA, LHJA, Series 1 to 4

Sun Hydraulics priority modulating element: LHDA, LHFA, LHHA, LHJA, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-31A, T-32A, T-33A, T-34A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Priority Modulating Element
- Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-31A, T-32A, T-33A, T-34A
- Valve function
- Priority Modulating Element
- Series (frame sizes)
- 1 to 4
- Cavity
- T-31A, T-32A, T-33A, T-34A
Product description
A bypass/restrictive modulating element that, with an external orifice, makes a priority flow control: inlet flow at port 3 goes to the priority outlet (port 2) first and the excess bypasses out of port 4. It controls pressure and flow on the priority side whatever the bypass pressure.
Sizes and cavities
Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:
- LHDA — series 1, T-31A cavity, 15 gpm (60 L/min)
- LHFA — series 2, T-32A cavity, 30 gpm (120 L/min)
- LHHA — series 3, T-33A cavity, 60 gpm (240 L/min)
- LHJA — series 4, T-34A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
Configuration options
The letters after the base model code choose these options (shown for LHDA; a size may add or drop a choice):
- Control: X — Not Adjustable
- Seal material: N — Buna-N, V — Viton, E — EPDM
Option rules: If the seal is E, the control must be X.
Selection notes
- Works in open- and closed-centre systems alike.
Where it is used
Running after-market attachments off a machine's existing hydraulics without an extra pump.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990031007, Polyurethane: 990031002, Viton: 990031006; series 2: Buna: 990032007, EPDM: 990032014, Polyurethane: 990032002, Viton: 990032006; series 3: Buna: 990033007, EPDM: 990033014, Polyurethane: 990033002, Viton: 990033006; series 4: Buna: 990034007, EPDM: 990034014, Polyurethane: 990034002, Viton: 990034006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example LHDAXFN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Priority Modulating Element |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-31A, T-32A, T-33A, T-34A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 15 gpm to 120 gpm (60 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | X — Not Adjustable |
| Seal material | N — Buna-N, V — Viton, E — EPDM |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990031007, Polyurethane: 990031002, Viton: 990031006; series 2: Buna: 990032007, EPDM: 990032014, Polyurethane: 990032002, Viton: 990032006; series 3: Buna: 990033007, EPDM: 990033014, Polyurethane: 990033002, Viton: 990033006; series 4: Buna: 990034007, EPDM: 990034014, Polyurethane: 990034002, Viton: 990034006 |
| Weight | .40 lb (0,20 kg) to 3.30 lb (1,50 kg) |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.LHDA
- Series
- 1
- Cavity
- T-31A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.LHFA
- Series
- 2
- Cavity
- T-32A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.LHHA
- Series
- 3
- Cavity
- T-33A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.LHJA
- Series
- 4
- Cavity
- T-34A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics LHDA, LHFA, LHHA, LHJA priority modulating element used for?▾
Which sizes and versions does the Sun Hydraulics LHDA, LHFA, LHHA, LHJA priority modulating element come in?▾
How do I read the Sun Hydraulics model code LHDAXFN for the LHDA, LHFA, LHHA, LHJA priority modulating element?▾
What is the maximum operating pressure of the Sun Hydraulics LHDA, LHFA, LHHA, LHJA priority modulating element?▾
What flow capacity does the Sun Hydraulics LHDA, LHFA, LHHA, LHJA priority modulating element have by series?▾
Which seal materials and body finishes does the Sun Hydraulics LHDA, LHFA, LHHA, LHJA priority modulating element come with?▾
Which cavity does the Sun Hydraulics LHDA, LHFA, LHHA, LHJA priority modulating element fit?▾
Which seal kit fits the Sun Hydraulics LHDA, LHFA, LHHA, LHJA priority modulating element?▾
How is the Sun Hydraulics LHDA, LHFA, LHHA, LHJA priority modulating element installed?▾
Where is the Sun Hydraulics LHDA, LHFA, LHHA, LHJA priority modulating element used?▾
Sun Hydraulics LHDA, LHFA, LHHA, LHJA or FRBA, FRCA, FRDA, FREA, FRFA: what is the difference?▾
Do you stock the Sun Hydraulics LHDA, LHFA, LHHA, LHJA in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations








