Sun Hydraulics Fixed-Orifice, Bypass/Restrictive, Priority, Flow Control Valve — FRBA, FRCA, FRDA, FREA, FRFA, Series 0 to 4

Sun Hydraulics priority flow control valve: FRBA, FRCA, FRDA, FREA, FRFA, series 0 to 4, 3 gpm to 50 gpm (11 L/min to 200 L/min), T-163A, T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Priority Flow Control Valve
- Capacity: 3 gpm to 50 gpm (11 L/min to 200 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-163A, T-11A, T-2A, T-17A, T-19A
- Valve function
- Priority Flow Control Valve
- Series (frame sizes)
- 0 to 4
- Cavity
- T-163A, T-11A, T-2A, T-17A, T-19A
Product description
A bypass/restrictive priority flow control takes the flow arriving at port 1, supplies a set priority flow to port 3, and sends any excess out of port 2 for a second circuit. Both outlets can be used up to full system pressure.
Sizes and cavities
Sun Hydraulics builds this valve in 5 sizes. The series sets the cavity it screws into and its flow capacity:
- FRBA — series 0, T-163A cavity, 3 gpm (11 L/min), 0-series
- FRCA — series 1, T-11A cavity, 6 gpm (23 L/min)
- FRDA — series 2, T-2A cavity, 12 gpm (45 L/min)
- FREA — series 3, T-17A cavity, 25 gpm (95 L/min)
- FRFA — series 4, T-19A cavity, 50 gpm (200 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
Configuration options
The letters after the base model code choose these options (shown for FRCA; a size may add or drop a choice):
- Control: L — Tuning Adjustment, K — Handknob, X — Not Adjustable, C — Tamper Resistant - Factory Set
- Setting range: A — Replaceable Orifice .1 - 6 gpm (0,4 - 23 L/min.), B — Permanent Orifice .1 - 6 gpm (0,4 - 23 L/min.)
- Seal material: N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated
Option rules: If the modifier is /AP, the control must be C, L or X.
Selection notes
- Priority flow stays fairly constant as input flow varies.
- You specify the priority flow; it is factory set.
Where it is used
Giving steering, brakes or a key function first call on one pump, with the rest going to other work.
Installation and seal kits
Valve hex 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 0: Buna: 990163007, Polyurethane: 990163002, Viton: 990163006; series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example FRCAXAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Priority Flow Control Valve |
| Series (frame sizes) | 0 to 4 |
| Cavity | T-163A, T-11A, T-2A, T-17A, T-19A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 3 gpm to 50 gpm (11 L/min to 200 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — Replaceable Orifice .1 - 6 gpm (0,4 - 23 L/min.), B — Permanent Orifice .1 - 6 gpm (0,4 - 23 L/min.) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | L — Tuning Adjustment, K — Handknob, X — Not Adjustable, C — Tamper Resistant - Factory Set |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 0: Buna: 990163007, Polyurethane: 990163002, Viton: 990163006; series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, EPDM: 990202014, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006 |
| Weight | .20 lb (0,10 kg) to 2.70 lb (1,25 kg) |
Shipping & lead time
Sizes & part numbers
5 sizes- Sun Hydraulics part no.FRBA
- Description
- 0-Series
- Series
- 0
- Cavity
- T-163A
- Capacity
- 3 gpm / 11 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.FRCA
- Description
- Standard
- Series
- 1
- Cavity
- T-11A
- Capacity
- 6 gpm / 23 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.FRDA
- Description
- Standard
- Series
- 2
- Cavity
- T-2A
- Capacity
- 12 gpm / 45 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.FREA
- Description
- Standard
- Series
- 3
- Cavity
- T-17A
- Capacity
- 25 gpm / 95 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.FRFA
- Description
- Standard
- Series
- 4
- Cavity
- T-19A
- Capacity
- 50 gpm / 200 L/min
- Max pressure
- 5000 psi / 350 bar
Description — What this part number is, as the manufacturer lists it. Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics FRBA, FRCA, FRDA, FREA, FRFA priority flow control valve used for?▾
Which sizes and versions does the Sun Hydraulics FRBA, FRCA, FRDA, FREA, FRFA priority flow control valve come in?▾
How do I read the Sun Hydraulics model code FRCAXAN for the FRBA, FRCA, FRDA, FREA, FRFA priority flow control valve?▾
What is the maximum operating pressure of the Sun Hydraulics FRBA, FRCA, FRDA, FREA, FRFA priority flow control valve?▾
What flow capacity does the Sun Hydraulics FRBA, FRCA, FRDA, FREA, FRFA priority flow control valve have by series?▾
Which seal materials and body finishes does the Sun Hydraulics FRBA, FRCA, FRDA, FREA, FRFA priority flow control valve come with?▾
Which cavity does the Sun Hydraulics FRBA, FRCA, FRDA, FREA, FRFA priority flow control valve fit?▾
Which seal kit fits the Sun Hydraulics FRBA, FRCA, FRDA, FREA, FRFA priority flow control valve?▾
How is the Sun Hydraulics FRBA, FRCA, FRDA, FREA, FRFA priority flow control valve installed?▾
Where is the Sun Hydraulics FRBA, FRCA, FRDA, FREA, FRFA priority flow control valve used?▾
Sun Hydraulics FRBA, FRCA, FRDA, FREA, FRFA or FREL: what is the difference?▾
Do you stock the Sun Hydraulics FRBA, FRCA, FRDA, FREA, FRFA in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations