Weak Link

Weak Link, in 4 sizes. Indus part numbers.
Key features
- Product type: Weak Link
- Size range: 12 mm to 28 mm
Product description
Weak link designed to break at a set load.
Sizes
4 sizes, from 12 mm to 28 mm. Every size has its own Indus part number in the table below. The letters in the table match the dimension drawing.
Proof and breaking loads are as published for each size. They are test values, not working loads.
Dimensions are typical and can vary slightly between production runs; the drawing sent with the quotation is final.
Specifying
State the chain or wire size the connector joins, the load you need and the certificate required.
Ordering
Quote the Indus part number from the size table, or send the size and rating you need.
Identification
| Parameter | Value |
|---|---|
| Product type | Weak Link |
| Sizes | 4 |
Dimensions
| Parameter | Value |
|---|---|
| Size range | 12 mm to 28 mm |
Performance
| Parameter | Value |
|---|---|
| Minimum breaking load | 109–657 kN |
Shipping & lead time
Sizes & part numbers
4 sizes- Indus part no.IH-MR-CN-WKL-0120
- Size
- 12 mm
- Min breaking load (kN)
- 109
- A (mm)
- 80
- B (mm)
- 50
- Indus part no.IH-MR-CN-WKL-0174
- Size
- 17.4 mm
- Min breaking load (kN)
- 239
- A (mm)
- 140
- B (mm)
- 80
- Indus part no.IH-MR-CN-WKL-0212
- Size
- 21.2 mm
- Min breaking load (kN)
- 338
- A (mm)
- 160
- B (mm)
- 95
- Indus part no.IH-MR-CN-WKL-0280
- Size
- 28 mm
- Min breaking load (kN)
- 657
- A (mm)
- 190
- B (mm)
- 110
Size — Nominal size as the manufacturer states it. Min breaking load — Minimum breaking load. A test figure — never lift to it. A — Dimension A on the manufacturer dimension drawing. B — Dimension B on the manufacturer dimension drawing. Ask us for the dimension drawing if you need it stamped.
WLL is the most the part may carry in service. Proof and breaking loads are test figures — never lift to them. Each load is shown in the unit the manufacturer rates the part in, and a size ships with the manufacturer’s test certificate.
This range is published with a breaking load only, not a working load limit. Tell us the duty before using it to lift, and we will confirm a rating or recommend a rated part.
What is the Weak Link and what is it used for?▾
Which sizes of Weak Link are available?▾
How do I choose the right size of Weak Link?▾
What is the minimum breaking load of the Weak Link?▾
What do I send to get a quote for the Weak Link?▾
Weak Link or Weak Link System: what is the difference?▾
Are the dimensions in the Weak Link size table exact?▾
What certificate comes with the Weak Link?▾
What does the Weak Link connect to?▾
How should the Weak Link be inspected and installed?▾
What are the typical uses of the Weak Link?▾
Can I buy the Weak Link ex-stock from Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog








