Sun Hydraulics Vented Pilot-to-Open Check Valve, Atmospherically Referenced — CKCV, CKEV, CKGV, CKIV, Series 1 to 4

Sun Hydraulics Vented Pilot-to-Open Check Valve, Atmospherically Referenced: CKCV, CKEV, CKGV, CKIV, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Vented Pilot-to-Open Check Valve
- Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-11A, T-2A, T-17A, T-19A
- Valve function
- Vented Pilot-to-Open Check Valve
- Series (frame sizes)
- 1 to 4
- Cavity
- T-11A, T-2A, T-17A, T-19A
Product description
A pilot-to-open check whose spring chamber is vented, so pressure at port 2 does not oppose the pilot. Oil flows freely from port 2 to the actuator at port 1; pilot pressure at port 3 opens the return path. The pilot is sealed.
This version
- Atmospherically referenced: the spring chamber vents through the hex end.
Sizes and cavities
Sun Hydraulics builds this valve in 4 versions:
- CKCV — series 1, T-11A cavity, 15 gpm (60 L/min)
- CKEV — series 2, T-2A cavity, 30 gpm (120 L/min)
- CKGV — series 3, T-17A cavity, 60 gpm (240 L/min)
- CKIV — series 4, T-19A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Pilot ratio: 3:1
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 1 drops/min. (0,07 cc/min)
Configuration options
The letters after the base model code choose these options (shown for CKCV; a size may add or drop a choice):
- Control: S — External 4-SAE Vent Port, X — Standard Pilot, Atmospheric Vent, L — Manual Load Release, External Vent
- Check cracking pressure: A — 4 psi (0,3 bar), B — 15 psi (1 bar), C — 30 psi (2 bar), D — 50 psi (3,5 bar), E — 75 psi (5 bar), F — 100 psi (7 bar)
- Seal material: N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /AP, the control must be X; If the modifier is /LH, the control must be L or X.
Selection notes
- About 75 psi (5 bar) of pilot pressure above the vent pressure can hold the valve open, so keep the pilot line clear of trapped pressure.
- Atmospherically referenced versions fix existing non-vented circuits but can, over time, weep oil or draw moisture into the spring chamber; a 4-port vented valve is the better choice for a new design.
Where it is used
Locking circuits with back-pressure in the return line — regeneration, motion-control valves with restrictive spools, shared return lines.
Installation and seal kits
Hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990311007, Polyurethane: 990011002, Viton: 990311006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example CKCVXCN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990311007, Polyurethane: 990011002, Viton: 990311006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, Polyurethane: 990019002, Viton: 990019006 |
| Weight | .20 lb (0,10 kg) to 2.80 lb (1,30 kg) |
Identification
| Parameter | Value |
|---|---|
| Valve function | Vented Pilot-to-Open Check Valve |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-11A, T-2A, T-17A, T-19A |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | S — External 4-SAE Vent Port, X — Standard Pilot, Atmospheric Vent, L — Manual Load Release, External Vent |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Performance
| Parameter | Value |
|---|---|
| Capacity | 15 gpm to 120 gpm (60 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Pilot ratio | 3:1 |
| Setting range | A — 4 psi (0,3 bar), B — 15 psi (1 bar), C — 30 psi (2 bar), D — 50 psi (3,5 bar), E — 75 psi (5 bar), F — 100 psi (7 bar) |
| Max leakage | 1 drops/min. (0,07 cc/min) |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.CKCV
- Series
- 1
- Cavity
- T-11A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.CKEV
- Series
- 2
- Cavity
- T-2A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.CKGV
- Series
- 3
- Cavity
- T-17A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.CKIV
- Series
- 4
- Cavity
- T-19A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics CKCV, CKEV, CKGV, CKIV vented pilot-to-open check valve used for?▾
Which sizes and versions does the Sun Hydraulics CKCV, CKEV, CKGV, CKIV vented pilot-to-open check valve come in?▾
How do I read the Sun Hydraulics model code CKCVXCN for the CKCV, CKEV, CKGV, CKIV vented pilot-to-open check valve?▾
What is the maximum operating pressure of the Sun Hydraulics CKCV, CKEV, CKGV, CKIV vented pilot-to-open check valve?▾
What flow capacity does the Sun Hydraulics CKCV, CKEV, CKGV, CKIV vented pilot-to-open check valve have by series?▾
Which seal materials and body finishes does the Sun Hydraulics CKCV, CKEV, CKGV, CKIV vented pilot-to-open check valve come with?▾
Which cavity does the Sun Hydraulics CKCV, CKEV, CKGV, CKIV vented pilot-to-open check valve fit?▾
Which seal kit fits the Sun Hydraulics CKCV, CKEV, CKGV, CKIV vented pilot-to-open check valve?▾
How is the Sun Hydraulics CKCV, CKEV, CKGV, CKIV vented pilot-to-open check valve installed?▾
Where is the Sun Hydraulics CKCV, CKEV, CKGV, CKIV vented pilot-to-open check valve used?▾
Sun Hydraulics CKCV, CKEV, CKGV, CKIV or CVCV, CVEV, CVGV, CVIV: what is the difference?▾
Do you stock the Sun Hydraulics CKCV, CKEV, CKGV, CKIV in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations








