Sun Hydraulics Flush Mount Pilot-to-Open Check Valve with Sealed Pilot — CKBG

Sun Hydraulics Flush Mount Pilot-to-Open Check Valve with Sealed Pilot: CKBG, series 0, 7.5 gpm (30 L/min), T-163A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Pilot-to-Open Check Valve
- Capacity: 7.5 gpm (30 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-163A
- Valve function
- Pilot-to-Open Check Valve
- Series (frame sizes)
- 0
- Cavity
- T-163A
Product description
A pilot-to-open check lets oil flow freely from the valve side (port 2) into the actuator (port 1) and locks it there. Pressure at the pilot port (port 3) lifts the poppet so the actuator can return. The pilot pressure needed rises with the load pressure, and pressure at port 2 works against the pilot.
This version
- Flush-mount body: sits level with the manifold face for a small footprint.
- Sealed pilot, for circuits where leakage from the pilot to the work ports is not acceptable.
Sizes and cavities
Sun Hydraulics builds this valve in one version:
- CKBG — series 0, T-163A cavity, 7.5 gpm (30 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Pilot ratio: 3:1
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 1 drops/min. (0,07 cc/min)
Configuration options
The letters after the base model code choose these options (shown for CKBG; a size may add or drop a choice):
- Control: X — Not Adustable, Standard Hydraulic Pilot
- Setting range: C — 30 psi (2 bar), E — 75 psi (5 bar)
- Seal material: N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /AP, the control must be X; If the modifier is /LH, the control must be X.
Selection notes
- Steel seat, heat-treated poppet: if a load drifts through it, the seat has usually been damaged and the cartridge should be replaced.
- Fits the same cavity, with the same flow path, as a 3-port counterbalance valve of the same frame size; the height above the manifold may differ.
Where it is used
Locking cylinders on outriggers, clamps, tipping bodies and presses; hose-burst protection.
Installation and seal kits
Replacement seal kits — series 0: Buna: 990163007, Polyurethane: 990163002, Viton: 990163006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example CKBGXCN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | X — Not Adustable, Standard Hydraulic Pilot |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Performance
| Parameter | Value |
|---|---|
| Capacity | 7.5 gpm (30 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Pilot ratio | 3:1 |
| Setting range | C — 30 psi (2 bar), E — 75 psi (5 bar) |
| Max leakage | 1 drops/min. (0,07 cc/min) |
Identification
| Parameter | Value |
|---|---|
| Valve function | Pilot-to-Open Check Valve |
| Series (frame sizes) | 0 |
| Cavity | T-163A |
Installation
| Parameter | Value |
|---|---|
| Installation torque | 20 - 25 lbf ft (27 - 33 Nm) |
| Seal kits | series 0: Buna: 990163007, Polyurethane: 990163002, Viton: 990163006 |
| Weight | .20 lb (0,10 kg) |
Shipping & lead time
Sizes & part numbers
1 size- Sun Hydraulics part no.CKBG
- Series
- 0
- Cavity
- T-163A
- Capacity
- 7.5 gpm / 30 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics CKBG pilot-to-open check valve used for?▾
Which sizes and versions does the Sun Hydraulics CKBG pilot-to-open check valve come in?▾
How do I read the Sun Hydraulics model code CKBGXCN for the CKBG pilot-to-open check valve?▾
What is the maximum operating pressure of the Sun Hydraulics CKBG pilot-to-open check valve?▾
What flow capacity does the CKBG pilot-to-open check valve have?▾
Which seal materials and body finishes does the Sun Hydraulics CKBG pilot-to-open check valve come with?▾
Which cavity does the Sun Hydraulics CKBG pilot-to-open check valve fit?▾
Which seal kit fits the Sun Hydraulics CKBG pilot-to-open check valve?▾
How is the Sun Hydraulics CKBG pilot-to-open check valve installed?▾
Where is the Sun Hydraulics CKBG pilot-to-open check valve used?▾
Sun Hydraulics CKBG or CKCS: what is the difference?▾
Do you stock the Sun Hydraulics CKBG in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations