Skip to content
SUN HYDRAULICSIH-SUN-CV-V

Sun Hydraulics Vented Pilot-to-Open Check Valve — CVCV, CVEV, CVGV, CVIV, Series 1 to 4

Check, Shuttle & Directional CartridgesEx-stock · delivery in 3 days
Sun Hydraulics CVCV vented pilot-to-open check valve, series 1, T-21A cavity — dimension drawing
VIEW 01·Sun Hydraulics CVCV vented pilot-to-open check valve, series 1, T-21A cavity — dimension drawing
1 / 3

Sun Hydraulics Vented Pilot-to-Open Check Valve: CVCV, CVEV, CVGV, CVIV, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-21A, T-22A, T-23A, T-24A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Vented Pilot-to-Open Check Valve
  • Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-21A, T-22A, T-23A, T-24A
Valve function
Vented Pilot-to-Open Check Valve
Series (frame sizes)
1 to 4
Cavity
T-21A, T-22A, T-23A, T-24A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A pilot-to-open check whose spring chamber is vented, so pressure at port 2 does not oppose the pilot. Oil flows freely from port 2 to the actuator at port 1; pilot pressure at port 3 opens the return path. The pilot is sealed.

Sizes and cavities

Sun Hydraulics builds this valve in 4 versions:

  • CVCV — series 1, T-21A cavity, 15 gpm (60 L/min)
  • CVEV — series 2, T-22A cavity, 30 gpm (120 L/min)
  • CVGV — series 3, T-23A cavity, 60 gpm (240 L/min)
  • CVIV — series 4, T-24A cavity, 120 gpm (480 L/min)

Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Pilot ratio: 3:1
  • Maximum operating pressure: 5000 psi (350 bar)
  • Maximum leakage: 1 drops/min. (0,07 cc/min)

Configuration options

The letters after the base model code choose these options (shown for CVCV; a size may add or drop a choice):

  • Control: X — Standard Pilot, L — Manual Load Release
  • Check cracking pressure: C — 30 psi (2 bar), A — 4 psi (0,3 bar), B — 15 psi (1 bar), D — 50 psi (3,5 bar), E — 75 psi (5 bar), F — 100 psi (7 bar)
  • Seal material: N — Buna-N, V — Viton, E — EPDM
  • Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Option rules: If the modifier is /AP, the control must be X; If the modifier is /LH, the control must be L or X; If the seal is E, the control must be L or X.

Selection notes

  • About 75 psi (5 bar) of pilot pressure above the vent pressure can hold the valve open, so keep the pilot line clear of trapped pressure.
  • Atmospherically referenced versions fix existing non-vented circuits but can, over time, weep oil or draw moisture into the spring chamber; a 4-port vented valve is the better choice for a new design.

Where it is used

Locking circuits with back-pressure in the return line — regeneration, motion-control valves with restrictive spools, shared return lines.

Installation and seal kits

Hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, EPDM: 990024014, Polyurethane: 990024002, Viton: 990024006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example CVCVXCN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.

Installation

ParameterValue
Valve hex size7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm)
Installation torque30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm)
Seal kitsseries 1: Buna: 990021007, EPDM: 990021014, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, EPDM: 990024014, Polyurethane: 990024002, Viton: 990024006
Weight.40 lb (0,20 kg) to 2.50 lb (1,15 kg)

Identification

ParameterValue
Valve functionVented Pilot-to-Open Check Valve
Series (frame sizes)1 to 4
CavityT-21A, T-22A, T-23A, T-24A

Configuration

ParameterValue
Control / adjustmentX — Standard Pilot, L — Manual Load Release
Seal materialN — Buna-N, V — Viton, E — EPDM
Material / coating/AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Performance

ParameterValue
Capacity15 gpm to 120 gpm (60 L/min to 480 L/min)
Max operating pressure5000 psi (350 bar)
Pilot ratio3:1
Setting rangeC — 30 psi (2 bar), A — 4 psi (0,3 bar), B — 15 psi (1 bar), D — 50 psi (3,5 bar), E — 75 psi (5 bar), F — 100 psi (7 bar)
Max leakage1 drops/min. (0,07 cc/min)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

RELATED · OFTEN PAIRED WITH