Skip to content
SUN HYDRAULICSIH-SUN-SX-A

Sun Hydraulics Direct-Acting Sequence Valve Without Reverse Flow Check — SXCA, SXEA, Series 1 to 2

Relief, Reducing & Sequence CartridgesEx-stock · delivery in 3 days
Sun Hydraulics SXCA direct-acting sequence valve, series 1, T-11A cavity — dimension drawing
VIEW 01·Sun Hydraulics SXCA direct-acting sequence valve, series 1, T-11A cavity — dimension drawing
1 / 3

Sun Hydraulics direct-acting sequence valve: SXCA, SXEA, series 1 to 2, 15 gpm to 30 gpm (60 L/min to 120 L/min), T-11A, T-2A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Direct-Acting Sequence Valve
  • Capacity: 15 gpm to 30 gpm (60 L/min to 120 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-11A, T-2A
Valve function
Direct-Acting Sequence Valve
Series (frame sizes)
1 to 2
Cavity
T-11A, T-2A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A direct-acting sequence cartridge keeps a second branch closed until pressure at its inlet (port 1) passes the setting, then feeds that branch through port 2. The setting is referenced to the drain at port 3. Versions with a reverse-flow check let oil return freely from port 2 to port 1.

Sizes and cavities

Sun Hydraulics builds this valve in 2 sizes. The series sets the cavity it screws into and its flow capacity:

  • SXCA — series 1, T-11A cavity, 15 gpm (60 L/min)
  • SXEA — series 2, T-2A cavity, 30 gpm (120 L/min)

Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)
  • Maximum leakage: 10 drops/min. (0,7 cc/min)
  • Typical response time: 2 ms

Configuration options

The letters after the base model code choose these options (shown for SXCA; a size may add or drop a choice):

  • Control: C — Tamper Resistant - Factory Set, L — Standard Screw Adjustment, K — Handknob
  • Setting range: A — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 300 - 1500 psi (20 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 2000 - 6000 psi (140 - 420 bar), 2000 psi (140 bar) Standard Setting, D — 200 - 800 psi (14 - 55 bar), 400 psi (28 bar) Standard Setting, E — 100 - 400 psi (7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 800 - 4500 psi (55 - 315 bar), 1000 psi (70 bar) Standard Setting
  • Seal material: N — Buna-N, V — Viton
  • Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Option rules: If the modifier is /AP, the control must be C or L; If the modifier is /LH, the control must be L.

Selection notes

  • Port 3 must be piped to tank even though there is no pilot flow.
  • Pressure at port 3 adds one-for-one to the setting.
  • Sun's 3-port sequence cartridges of one frame size share the same cavity and flow path.

Where it is used

Clamp-then-work sequences, two-stage cylinders and priority between functions on one pump.

Installation and seal kits

Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm). Replacement seal kits — series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example SXCALAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.

Identification

ParameterValue
Valve functionDirect-Acting Sequence Valve
Series (frame sizes)1 to 2
CavityT-11A, T-2A

Performance

ParameterValue
Capacity15 gpm to 30 gpm (60 L/min to 120 L/min)
Max operating pressure5000 psi (350 bar)
Setting rangeA — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 300 - 1500 psi (20 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 2000 - 6000 psi (140 - 420 bar), 2000 psi (140 bar) Standard Setting, D — 200 - 800 psi (14 - 55 bar), 400 psi (28 bar) Standard Setting, E — 100 - 400 psi (7 - 28 bar), 200 psi (14 bar) Standard Setting, W — 800 - 4500 psi (55 - 315 bar), 1000 psi (70 bar) Standard Setting
Max leakage10 drops/min. (0,7 cc/min)

Configuration

ParameterValue
Control / adjustmentC — Tamper Resistant - Factory Set, L — Standard Screw Adjustment, K — Handknob
Seal materialN — Buna-N, V — Viton
Material / coating/AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Installation

ParameterValue
Valve hex size7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm)
Installation torque30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm)
Seal kitsseries 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006
Weight.30 lb (0,15 kg) to .60 lb (0,30 kg)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

RELATED · OFTEN PAIRED WITH