Sun Hydraulics Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3 — SDFT, SDHT, SDJT, Series 2 to 4

Sun Hydraulics anti-shock sequence valve with drain: SDFT, SDHT, SDJT, series 2 to 4, 30 gpm to 120 gpm (120 L/min to 480 L/min), T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Anti-Shock Sequence Valve with Drain
- Capacity: 30 gpm to 120 gpm (120 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-2A, T-17A, T-19A
- Valve function
- Anti-Shock Sequence Valve with Drain
- Series (frame sizes)
- 2 to 4
- Cavity
- T-2A, T-17A, T-19A
Product description
A pilot-operated, balanced-poppet sequence valve that limits both the maximum pressure and how fast pressure rises: it opens, then closes again at a controlled rate. An external drain makes it insensitive to pressure at port 2.
Sizes and cavities
Sun Hydraulics builds this valve in 3 sizes. The series sets the cavity it screws into and its flow capacity:
- SDFT — series 2, T-2A cavity, 30 gpm (120 L/min)
- SDHT — series 3, T-17A cavity, 60 gpm (240 L/min)
- SDJT — series 4, T-19A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 10 drops/min. (0,7 cc/min)
- Typical response time: 2 ms
Configuration options
The letters after the base model code choose these options (shown for SDJT; a size may add or drop a choice):
- Control: C — Concealed Manual Override, L — Standard Screw Adjustment
- Setting range: A — 2000 - 3000 psi (140 - 210 bar), 2000 psi (140 bar) Standard Setting, C — 4500 - 6000 psi (315 - 420 bar), 4500 psi (315 bar) Standard Setting, W — 3000 - 4500 psi (210 - 315 bar), 3000 psi (210 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton
- Material / coating: /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /LH, the control must be C or L.
Selection notes
- Not for load-holding duty.
- One adjustment sets both the relief and threshold pressures.
Where it is used
Cushioning pressure spikes in circuits where the return or secondary line is pressurised.
Installation and seal kits
Valve hex 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 2: Buna: 990402007, Polyurethane: 990002002, Viton: 990402006; series 3: Buna: 990217007, Polyurethane: 990217002, Viton: 990217006; series 4: Buna: 990219007, Viton: 990219006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example SDJTLAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Anti-Shock Sequence Valve with Drain |
| Series (frame sizes) | 2 to 4 |
| Cavity | T-2A, T-17A, T-19A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 30 gpm to 120 gpm (120 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 2000 - 3000 psi (140 - 210 bar), 2000 psi (140 bar) Standard Setting, C — 4500 - 6000 psi (315 - 420 bar), 4500 psi (315 bar) Standard Setting, W — 3000 - 4500 psi (210 - 315 bar), 3000 psi (210 bar) Standard Setting |
| Max leakage | 10 drops/min. (0,7 cc/min) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | C — Concealed Manual Override, L — Standard Screw Adjustment |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /LH — Mild Steel, Zinc-Nickel |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 2: Buna: 990402007, Polyurethane: 990002002, Viton: 990402006; series 3: Buna: 990217007, Polyurethane: 990217002, Viton: 990217006; series 4: Buna: 990219007, Viton: 990219006 |
| Weight | 1.50 lb (0,70 kg) |
Shipping & lead time
Sizes & part numbers
3 sizes- Sun Hydraulics part no.SDFT
- Series
- 2
- Cavity
- T-2A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.SDHT
- Series
- 3
- Cavity
- T-17A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.SDJT
- Series
- 4
- Cavity
- T-19A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3 (SDFT, SDHT, SDJT) and what does it do?▾
How do I read the Sun model code for the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3 (SDFT, SDHT, SDJT)?▾
What sizes and flow capacities does the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3 come in?▾
What pressure and setting range does the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3 have?▾
Which seal and material options does the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3 come with?▾
How is the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3 adjusted, and which control options are offered?▾
Which seal kit fits the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3 (SDFT, SDHT, SDJT)?▾
Which cavity and installation torque does the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3 need?▾
Where is the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3 used?▾
How does the Sun SDFT valve differ from the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Relief Valve?▾
Why an anti-shock sequence rather than an anti-shock relief on the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3?▾
Do you stock the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Sequence Valve with Drain to Port 3 in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations








