- Valve function: Direct-Acting Sequence Valve
- Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-11A, T-2A, T-17A, T-19A
- Valve function
- Direct-Acting Sequence Valve
- Series (frame sizes)
- 1 to 4
- Cavity
- T-11A, T-2A, T-17A, T-19A
Product description
A direct-acting sequence cartridge keeps a second branch closed until pressure at its inlet (port 1) passes the setting, then feeds that branch through port 2. The setting is referenced to the drain at port 3. Versions with a reverse-flow check let oil return freely from port 2 to port 1.
Sizes and cavities
Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:
- SCCA — series 1, T-11A cavity, 15 gpm (60 L/min)
- SCEA — series 2, T-2A cavity, 30 gpm (120 L/min)
- SCGA — series 3, T-17A cavity, 60 gpm (240 L/min)
- SCIA — series 4, T-19A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 10 drops/min. (0,7 cc/min)
- Typical response time: 2 ms
- Check cracking pressure: 40 psi (2,8 bar), 25 psi (1,7 bar)
Configuration options
The letters after the base model code choose these options (shown for SCCA; a size may add or drop a choice):
- Control: L — Standard Screw Adjustment, C — Tamper Resistant - Factory Set, K — Handknob
- Setting range: A — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, W — 800 - 4500 psi (55 - 315 bar), 1000 psi (70 bar) Standard Setting, B — 300 - 1500 psi (20 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 2000 - 6000 psi (140 - 420 bar), 2000 psi (140 bar) Standard Setting, D — 200 - 800 psi (14 - 55 bar), 400 psi (28 bar) Standard Setting, E — 100 - 400 psi (7 - 28 bar), 200 psi (14 bar) Standard Setting
- Seal material: N — Buna-N, L — Extended Temp. Buna, V — Viton, E — EPDM
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: EPDM seals are not allowed on modifier /LH; If the modifier is /AP, the control must be C or L; If the modifier is /LH, the control must be C or L; If the seal is E, the control must be C,K or L.
Selection notes
- Port 3 must be piped to tank even though there is no pilot flow.
- Pressure at port 3 adds one-for-one to the setting.
- Sun's 3-port sequence cartridges of one frame size share the same cavity and flow path.
Where it is used
Clamp-then-work sequences, two-stage cylinders and priority between functions on one pump.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990011007, EPDM: 990011014, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example SCCALAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Direct-Acting Sequence Valve |
| Series (frame sizes) | 1 to 4 |
| Cavity | T-11A, T-2A, T-17A, T-19A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 15 gpm to 120 gpm (60 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, W — 800 - 4500 psi (55 - 315 bar), 1000 psi (70 bar) Standard Setting, B — 300 - 1500 psi (20 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 2000 - 6000 psi (140 - 420 bar), 2000 psi (140 bar) Standard Setting, D — 200 - 800 psi (14 - 55 bar), 400 psi (28 bar) Standard Setting, E — 100 - 400 psi (7 - 28 bar), 200 psi (14 bar) Standard Setting |
| Max leakage | 10 drops/min. (0,7 cc/min) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | L — Standard Screw Adjustment, C — Tamper Resistant - Factory Set, K — Handknob |
| Seal material | N — Buna-N, L — Extended Temp. Buna, V — Viton, E — EPDM |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 1: Buna: 990011007, EPDM: 990011014, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006 |
| Weight | .30 lb (0,15 kg) to 3.10 lb (1,40 kg) |
Shipping & lead time
Sizes & part numbers
4 sizes- Sun Hydraulics part no.SCCA
- Series
- 1
- Cavity
- T-11A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.SCEA
- Series
- 2
- Cavity
- T-2A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.SCGA
- Series
- 3
- Cavity
- T-17A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.SCIA
- Series
- 4
- Cavity
- T-19A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Direct-Acting Sequence Valve with Reverse Flow Check (SCCA, SCEA, SCGA and others) and what does it do?▾
How do I read the Sun model code for the Sun Direct-Acting Sequence Valve with Reverse Flow Check (SCCA, SCEA, SCGA and others)?▾
What sizes and flow capacities does the Sun Direct-Acting Sequence Valve with Reverse Flow Check come in?▾
What pressure and setting range does the Sun Direct-Acting Sequence Valve with Reverse Flow Check have?▾
Which seal and material options does the Sun Direct-Acting Sequence Valve with Reverse Flow Check come with?▾
How is the Sun Direct-Acting Sequence Valve with Reverse Flow Check adjusted, and which control options are offered?▾
Which seal kit fits the Sun Direct-Acting Sequence Valve with Reverse Flow Check (SCCA, SCEA, SCGA and others)?▾
Which cavity and installation torque does the Sun Direct-Acting Sequence Valve with Reverse Flow Check need?▾
Where is the Sun Direct-Acting Sequence Valve with Reverse Flow Check used?▾
How does the Sun SCCA valve differ from the Sun Atmospherically Referenced, Direct-Acting Sequence Valve with Reverse Flow Check?▾
What does a sequence valve do on the Sun Direct-Acting Sequence Valve with Reverse Flow Check?▾
Can I buy the Sun Direct-Acting Sequence Valve with Reverse Flow Check from stock in the UAE and get a quotation?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations