Skip to content
SUN HYDRAULICSIH-SUN-QC-ABCD

Sun Hydraulics Accumulator Sense, Pump Unload Valve with Check, Pilot Capacity — QCDA, QCDB, QCDC, QCDD, Series 1

Specialty & Multi-Function CartridgesEx-stock · delivery in 3 days
Sun Hydraulics QCDD accumulator sense pump unload valve, series 1, T-21A cavity — dimension drawing
VIEW 01·Sun Hydraulics QCDD accumulator sense pump unload valve, series 1, T-21A cavity — dimension drawing
1 / 3

Sun Hydraulics Accumulator Sense, Pump Unload Valve with Check, Pilot Capacity: QCDA, QCDB, QCDC, QCDD, series 1, 15 gpm (60 L/min), T-21A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Accumulator Sense Pump Unload Valve
  • Capacity: 15 gpm (60 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-21A
Valve function
Accumulator Sense Pump Unload Valve
Series (frame sizes)
1
Cavity
T-21A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A pilot valve that watches accumulator pressure at port 2. When it reaches the setting, the valve connects port 3 to port 4, venting a relief valve so the pump unloads. When accumulator pressure falls by the valve's differential, it closes again and the pump recharges the accumulator.

This version

  • Integral free-flow check from pump to accumulator, for pumps up to 15 gpm (60 L/min).

Sizes and cavities

Sun Hydraulics builds this valve in 4 versions:

  • QCDA — series 1, T-21A cavity, 15 gpm (60 L/min), 15% reset differential
  • QCDB — series 1, T-21A cavity, 15 gpm (60 L/min), 20% reset differential
  • QCDC — series 1, T-21A cavity, 15 gpm (60 L/min), 30% reset differential
  • QCDD — series 1, T-21A cavity, 15 gpm (60 L/min), 50% reset differential

Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)
  • Check cracking pressure: 4 psi (0,3 bar)

Configuration options

The letters after the base model code choose these options (shown for QCDD; a size may add or drop a choice):

  • Control: C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment
  • Setting range: A — 1000 - 3000 psi (70 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 500 - 1500 psi (35 - 105 bar), 500 psi (35 bar) Standard Setting, C — 2000 - 5000 psi (140 - 350 bar), 2000 psi (140 bar) Standard Setting, D — 250 - 800 psi (18 - 55 bar), 250 psi (18 bar) Standard Setting
  • Seal material: N — Buna-N, V — Viton

Selection notes

  • The unload-to-reload differential is held within +3/−2% of its stated ratio.
  • The sensing area is positively sealed.
  • Versions with an integral check suit pumps up to 15 gpm (60 L/min); for bigger pumps use the version without check and a separate check cartridge.

Where it is used

Accumulator charging circuits on presses, braking systems and power units with a fixed pump.

Installation and seal kits

Hex 7/8 in. (22,2 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm). Replacement seal kits — series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example QCDDLAN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.

Identification

ParameterValue
Valve functionAccumulator Sense Pump Unload Valve
Series (frame sizes)1
CavityT-21A

Performance

ParameterValue
Capacity15 gpm (60 L/min)
Max operating pressure5000 psi (350 bar)
Setting rangeA — 1000 - 3000 psi (70 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 500 - 1500 psi (35 - 105 bar), 500 psi (35 bar) Standard Setting, C — 2000 - 5000 psi (140 - 350 bar), 2000 psi (140 bar) Standard Setting, D — 250 - 800 psi (18 - 55 bar), 250 psi (18 bar) Standard Setting

Configuration

ParameterValue
Control / adjustmentC — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment
Seal materialN — Buna-N, V — Viton

Installation

ParameterValue
Valve hex size7/8 in. (22,2 mm)
Installation torque30 - 35 lbf ft (41 - 47 Nm)
Seal kitsseries 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006
Weight.35 lb (0,15 kg)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

RELATED · OFTEN PAIRED WITH