Sun Hydraulics CavitySaver™ Normally Closed Modulating Element Valve with Relief Function — RVBB, RVCB, RVEB, RVGB, RVIB, Series 0 to 4

Sun Hydraulics CavitySaver™ Normally Closed Modulating Element Valve with Relief Function: RVBB, RVCB, RVEB, RVGB, RVIB, series 0 to 4, 5 gpm to 80 gpm (20 L/min to 320 L/min), T-163A, T-11A, T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: CavitySaver Normally Closed Modulating Element with Relief
- Capacity: 5 gpm to 80 gpm (20 L/min to 320 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-163A, T-11A, T-2A, T-17A, T-19A
- Valve function
- CavitySaver Normally Closed Modulating Element with Relief
- Series (frame sizes)
- 0 to 4
- Cavity
- T-163A, T-11A, T-2A, T-17A, T-19A
Product description
A multi-function cartridge: a normally closed modulating element that, with an external orifice, works as a bypass compensator — the orifice sets a priority flow into the circuit and the rest goes to tank at port 2 — and also relieves the inlet once it reaches the setting. Two functions, one cavity.
This version
- Normally closed.
Sizes and cavities
Sun Hydraulics builds this valve in 5 versions:
- RVBB — series 0, T-163A cavity, 5 gpm (20 L/min)
- RVCB — series 1, T-11A cavity, 10 gpm (40 L/min)
- RVEB — series 2, T-2A cavity, 20 gpm (80 L/min)
- RVGB — series 3, T-17A cavity, 40 gpm (160 L/min)
- RVIB — series 4, T-19A cavity, 80 gpm (320 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 2 in³/min.@1000 psi (30 cc/min.@70 bar), 3 in³/min.@1000 psi (50 cc/min.@70 bar), 4 in³/min.@1000 psi (65 cc/min.@70 bar), 5 in³/min.@1000 psi (80 cc/min.@70 bar)
- Typical response time: 10 ms
Configuration options
The letters after the base model code choose these options (shown for RVCB; a size may add or drop a choice):
- Control: C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment
- Setting range: A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 150 - 6000 psi (10,5 - 420 bar), 1000 psi (70 bar) Standard Setting, D — 100 - 800 psi (7 - 55 bar), 400 psi (28 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 1000 psi (70 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Option rules: If the modifier is /AP, the control must be C or L; If the modifier is /LH, the control must be C or L.
Selection notes
- Compensating pressure is 50 psi (3.5 bar) in every range.
- Its capacity is set by the bypassed flow (pump flow minus controlled flow), not the controlled flow.
Where it is used
Fixed-displacement pump circuits that need a steady flow to one function and over-pressure protection.
Installation and seal kits
Hex 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 0: Buna: 990163007, Polyurethane: 990163002, Viton: 990163006; series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example RVCBLAN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | CavitySaver Normally Closed Modulating Element with Relief |
| Series (frame sizes) | 0 to 4 |
| Cavity | T-163A, T-11A, T-2A, T-17A, T-19A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 5 gpm to 80 gpm (20 L/min to 320 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting, B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting, C — 150 - 6000 psi (10,5 - 420 bar), 1000 psi (70 bar) Standard Setting, D — 100 - 800 psi (7 - 55 bar), 400 psi (28 bar) Standard Setting, W — 150 - 4500 psi (10,5 - 315 bar), 1000 psi (70 bar) Standard Setting |
| Max leakage | 2 in³/min.@1000 psi (30 cc/min.@70 bar), 3 in³/min.@1000 psi (50 cc/min.@70 bar), 4 in³/min.@1000 psi (65 cc/min.@70 bar), 5 in³/min.@1000 psi (80 cc/min.@70 bar) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 3/4 in. (19,1 mm), 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 20 - 25 lbf ft (27 - 33 Nm), 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 0: Buna: 990163007, Polyurethane: 990163002, Viton: 990163006; series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006; series 3: Buna: 990017007, Polyurethane: 990017002, Viton: 990017006; series 4: Buna: 990019007, EPDM: 990019014, Polyurethane: 990019002, Viton: 990019006 |
| Weight | .30 lb (0,15 kg) to 3.10 lb (1,40 kg) |
Shipping & lead time
Sizes & part numbers
5 sizes- Sun Hydraulics part no.RVBB
- Series
- 0
- Cavity
- T-163A
- Capacity
- 5 gpm / 20 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVCB
- Series
- 1
- Cavity
- T-11A
- Capacity
- 10 gpm / 40 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVEB
- Series
- 2
- Cavity
- T-2A
- Capacity
- 20 gpm / 80 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVGB
- Series
- 3
- Cavity
- T-17A
- Capacity
- 40 gpm / 160 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVIB
- Series
- 4
- Cavity
- T-19A
- Capacity
- 80 gpm / 320 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun CavitySaver™ Normally Closed Modulating Element Valve with Relief Function and what is it used for?▾
How do I read the Sun model code for the Sun CavitySaver™ Normally Closed Modulating Element Valve with Relief Function?▾
What versions and cavities does the Sun CavitySaver™ Normally Closed Modulating Element Valve with Relief Function come in?▾
What capacities and setting ranges do the Sun RV CavitySaver valves have?▾
What pressure and ratings does the Sun CavitySaver™ Normally Closed Modulating Element Valve with Relief Function have?▾
What seals and materials are available on the Sun CavitySaver™ Normally Closed Modulating Element Valve with Relief Function?▾
What hex size and installation torque does the Sun CavitySaver™ Normally Closed Modulating Element Valve with Relief Function need?▾
Which parts of the Sun CavitySaver™ Normally Closed Modulating Element Valve with Relief Function can be serviced, and how is it installed?▾
Where is the Sun CavitySaver™ Normally Closed Modulating Element Valve with Relief Function used?▾
How does the Sun RV CavitySaver valve work as a bypass compensator with relief?▾
How does the Sun RV normally closed element differ from the LPDS normally open element?▾
Can I get the Sun CavitySaver™ Normally Closed Modulating Element Valve with Relief Function supplied from Dubai, and how do I order it?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations








