Sun Hydraulics 3-Way, Vent-to-Operate, Directional Valve with Drain to Port 4 and Integral T-8A Control Cavity (1 to 2 Open, 3 Blocked) — DVBP, DVCP

Sun Hydraulics 3-Way, Vent-to-Operate, Directional Valve with Drain to Port 4 and Integral T-8A Control Cavity (1 to 2 Open, 3 Blocked): DVBP, DVCP, series 1 to 2, 7 gpm to 15 gpm (28 L/min to 60 L/min), T-21A, T-22A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Vent-to-Operate Directional Valve with T-8A Pilot Cavity
- Capacity: 7 gpm to 15 gpm (28 L/min to 60 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-21A, T-22A
- Valve function
- Vent-to-Operate Directional Valve with T-8A Pilot Cavity
- Series (frame sizes)
- 1 to 2
- Cavity
- T-21A, T-22A
Product description
A directional cartridge with its own T-8A pilot cavity. When the pilot cartridge screwed into that cavity opens and passes a small flow, the main stage shifts. There must be pressure at port 1, relative to port 3, to move it.
This version
- At rest: 1 to 2 open; 3 blocked.
- The spring chamber drains to a separate port 4, so pressure at port 3 does not shift the setting and port 3 can work as a load port.
- A T-8A pilot cavity is machined into the end, so a pilot cartridge screws straight in (ordered separately).
Sizes and cavities
Sun Hydraulics builds this valve in 2 versions:
- DVBP — series 1, T-21A cavity, 7 gpm (28 L/min)
- DVCP — series 2, T-22A cavity, 15 gpm (60 L/min)
Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Maximum leakage: 2 in³/min.@1000 psi (30 cc/min.@70 bar)
- Control pilot flow: 7 - 10 in³/min. (0,11 - 0,16 L/min)
Configuration options
The letters after the base model code choose these options (shown for DVBP; a size may add or drop a choice):
- Control: 8 — T-8A Cavity
- Setting range: F — 100 psi (7 bar)
- Seal material: N — Buna-N, V — Viton
Selection notes
- Pressure at port 3 can oppose opening — use a drain-to-port-4 version where port 3 carries load.
- It can modulate between positions; it is not a snap-acting switch.
Where it is used
Solenoid or manual switching of moderate flows without a separate pilot body or pilot lines.
Installation and seal kits
Hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm). Replacement seal kits — series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example DVBP8FN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm) |
| Seal kits | series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006 |
| Weight | .50 lb (0,25 kg) |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | 8 — T-8A Cavity |
| Seal material | N — Buna-N, V — Viton |
Identification
| Parameter | Value |
|---|---|
| Valve function | Vent-to-Operate Directional Valve with T-8A Pilot Cavity |
| Series (frame sizes) | 1 to 2 |
| Cavity | T-21A, T-22A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 7 gpm to 15 gpm (28 L/min to 60 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | F — 100 psi (7 bar) |
| Max leakage | 2 in³/min.@1000 psi (30 cc/min.@70 bar) |
Shipping & lead time
Sizes & part numbers
2 sizes- Sun Hydraulics part no.DVBP
- Series
- 1
- Cavity
- T-21A
- Capacity
- 7 gpm / 28 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.DVCP
- Series
- 2
- Cavity
- T-22A
- Capacity
- 15 gpm / 60 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Hydraulics DVBP, DVCP vent-to-operate directional valve with T-8A pilot cavity used for?▾
Which sizes and versions does the Sun Hydraulics DVBP, DVCP vent-to-operate directional valve with T-8A pilot cavity come in?▾
How do I read the Sun Hydraulics model code DVBP8FN for the DVBP, DVCP vent-to-operate directional valve with T-8A pilot cavity?▾
What is the maximum operating pressure of the Sun Hydraulics DVBP, DVCP vent-to-operate directional valve with T-8A pilot cavity?▾
What flow capacity does the Sun Hydraulics DVBP, DVCP vent-to-operate directional valve with T-8A pilot cavity have by series?▾
Which seal materials and body finishes does the Sun Hydraulics DVBP, DVCP vent-to-operate directional valve with T-8A pilot cavity come with?▾
Which cavity does the Sun Hydraulics DVBP, DVCP vent-to-operate directional valve with T-8A pilot cavity fit?▾
Which seal kit fits the Sun Hydraulics DVBP, DVCP vent-to-operate directional valve with T-8A pilot cavity?▾
How is the Sun Hydraulics DVBP, DVCP vent-to-operate directional valve with T-8A pilot cavity installed?▾
Where is the Sun Hydraulics DVBP, DVCP vent-to-operate directional valve with T-8A pilot cavity used?▾
Sun Hydraulics DVBP, DVCP or DVBD, DVCD: what is the difference?▾
Do you stock the Sun Hydraulics DVBP, DVCP in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations