MannTek CBC Cryogenic Breakaway Coupling for LNG, Breaking-Bolt Type — DN 25 to DN 200

MannTek CBC cryogenic breakaway coupling with breaking bolts: the weakest link in an LNG or liquid-gas hose line or loading arm, separating under excess pull with both valves closed. Industrial or marine version, DN 25 to DN 200, -196 °C, 25 bar. From Indus Hydraulics, authorised MannTek distributor, UAE.
Key features
- Coupling Family: Cryogenic Breakaway Coupling
- Coupling Type / Variant: Breaking-bolt type, industrial (0 to 90°) or marine (axial pull)
- End A Configuration: Female or male NPT thread, EN / ANSI / TW / TTMA flange or hose shank (chosen per side)
- End B Configuration: Female or male NPT thread, EN / ANSI / TW / TTMA flange or hose shank (chosen per side)
- Size Range: DN 25 (1") to DN 200 (8")
- Working Pressure: 25 bar (MannTek)
- Coupling Family
- Cryogenic Breakaway Coupling
- Coupling Type / Variant
- Breaking-bolt type, industrial (0 to 90°) or marine (axial pull)
- End A Configuration
- Female or male NPT thread, EN / ANSI / TW / TTMA flange or hose shank (chosen per side)
- End B Configuration
- Female or male NPT thread, EN / ANSI / TW / TTMA flange or hose shank (chosen per side)
- Size Range
- DN 25 (1") to DN 200 (8")
- Working Pressure
- 25 bar (MannTek)
Product description
A cryogenic breakaway coupling protects an LNG or liquid-gas transfer line against drive-aways and pull-aways at terminals and loading points. The MannTek CBC is installed as the weakest link in the hose line or loading arm. It is held together by breaking bolts: when the pull on the line reaches a defined force the bolts break, the coupling separates and the poppet valves in both halves close at once, keeping the product in the hose and the pipe.
It is built for cryogenic liquefied gases such as LNG, nitrogen, oxygen, argon and ethylene, down to -196 °C, and has what MannTek describes as a unique ice-breaking function. The CBC is passive: it works independently of the shut-off safety system, needs no external power, and has no loose parts to lose after a release.
Industrial or marine version
- Industrial: releases at any pull angle from 0 to 90°, straight or at an angle. Install it to at least one fixed point, for example at the tank truck or on the loading arm.
- Marine: releases on straight (axial) pull only. MannTek builds it with more resistance to torsion and bending loads, to prevent unwanted separation between two strings of hose.
Breaking load
MannTek calculates the breaking load for each installation. The coupling withstands extreme side load and has a low breaking force, and MannTek states the breaking force is less dependent on line pressure. After activation one person can reset it on site in minutes, without special tools.
Sizes and connections
DN 25 (1") to DN 200 (8"). Inlet and outlet are chosen individually, in any combination: female or male NPT thread, flanges to EN, ANSI, TW or TTMA, or an integrated hose shank, so no nipples or reducers are needed. MannTek publishes flow capacity from 460 L/min at DN 25 to 24,200 L/min at DN 200, with high flow and low pressure drop.
Construction
- Body: stainless steel
- Seals: engineered PTFE seals designed by MannTek
- Working pressure: 25 bar (MannTek)
- Service temperature: down to -196 °C
- Poppet valve design, which avoids damaged valve seats and over-rotating flaps
Where it is used
DN 25 for LNG refuelling and vapour return lines; DN 50 for heavy-vehicle refuelling and tank truck or container cargo; DN 65 to DN 100 for tank trucks, rail tankers, containers and truck-to-ship or shore-to-ship bunkering; DN 150 and DN 200 for marine bunkering and ship-to-ship or ship-to-shore transfer.
Indus Hydraulics is an authorised MannTek distributor in the UAE and supplies MannTek couplings direct from MannTek in Sweden.
How to order
Send the size, the version (industrial or marine), the inlet and outlet connections, the medium and how the line is installed, so MannTek can calculate the breaking load. We confirm the MannTek order code, price and lead time with the quotation.
Identification
| Parameter | Value |
|---|---|
| Coupling Family | Cryogenic Breakaway Coupling |
| Coupling Type / Variant | Breaking-bolt type, industrial (0 to 90°) or marine (axial pull) |
| Notes | For LNG and cryogenic liquefied gases down to -196 °C. Breaking load calculated by MannTek for each installation. |
| Manufacturer | MannTek (Mann Teknik AB), Mariestad, Sweden |
Configuration
| Parameter | Value |
|---|---|
| End A Configuration | Female or male NPT thread, EN / ANSI / TW / TTMA flange or hose shank (chosen per side) |
| End B Configuration | Female or male NPT thread, EN / ANSI / TW / TTMA flange or hose shank (chosen per side) |
Dimensions
| Parameter | Value |
|---|---|
| Size Range | DN 25 (1") to DN 200 (8") |
Construction
| Parameter | Value |
|---|---|
| Materials Available | Stainless steel |
| Seal / Gasket | PTFE |
Performance
| Parameter | Value |
|---|---|
| Working Pressure | 25 bar (MannTek) |
| Flow capacity | 460 L/min (DN 25) to 24,200 L/min (DN 200), as published by MannTek |
| Release | Breaking bolts; both valves close on separation |
| Service temperature | Down to -196 °C |
Shipping & lead time
Sizes & part numbers
14 sizes- Indus part no.IH-MNT-CBC-I-025
- Description
- Industrial version, releases at any pull angle from 0 to 90°. Body: stainless steel
- Nominal size
- 1" (DN 25)
- Max flow (L/min)
- 460
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-M-025
- Description
- Marine version, releases on straight (axial) pull only. Body: stainless steel
- Nominal size
- 1" (DN 25)
- Max flow (L/min)
- 460
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-I-050
- Description
- Industrial version, releases at any pull angle from 0 to 90°. Body: stainless steel
- Nominal size
- 2" (DN 50)
- Max flow (L/min)
- 1,650
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-M-050
- Description
- Marine version, releases on straight (axial) pull only. Body: stainless steel
- Nominal size
- 2" (DN 50)
- Max flow (L/min)
- 1,650
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-I-065
- Description
- Industrial version, releases at any pull angle from 0 to 90°. Body: stainless steel
- Nominal size
- 2-1/2" (DN 65)
- Max flow (L/min)
- 2,800
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-M-065
- Description
- Marine version, releases on straight (axial) pull only. Body: stainless steel
- Nominal size
- 2-1/2" (DN 65)
- Max flow (L/min)
- 2,800
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-I-080
- Description
- Industrial version, releases at any pull angle from 0 to 90°. Body: stainless steel
- Nominal size
- 3" (DN 80)
- Max flow (L/min)
- 3,850
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-M-080
- Description
- Marine version, releases on straight (axial) pull only. Body: stainless steel
- Nominal size
- 3" (DN 80)
- Max flow (L/min)
- 3,850
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
Show all 14 sizesShow fewer sizes
- Indus part no.IH-MNT-CBC-I-100
- Description
- Industrial version, releases at any pull angle from 0 to 90°. Body: stainless steel
- Nominal size
- 4" (DN 100)
- Max flow (L/min)
- 6,500
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-M-100
- Description
- Marine version, releases on straight (axial) pull only. Body: stainless steel
- Nominal size
- 4" (DN 100)
- Max flow (L/min)
- 6,500
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-I-150
- Description
- Industrial version, releases at any pull angle from 0 to 90°. Body: stainless steel
- Nominal size
- 6" (DN 150)
- Max flow (L/min)
- 14,400
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-M-150
- Description
- Marine version, releases on straight (axial) pull only. Body: stainless steel
- Nominal size
- 6" (DN 150)
- Max flow (L/min)
- 14,400
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-I-200
- Description
- Industrial version, releases at any pull angle from 0 to 90°. Body: stainless steel
- Nominal size
- 8" (DN 200)
- Max flow (L/min)
- 24,200
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
- Indus part no.IH-MNT-CBC-M-200
- Description
- Marine version, releases on straight (axial) pull only. Body: stainless steel
- Nominal size
- 8" (DN 200)
- Max flow (L/min)
- 24,200
- Mount
- EN, ANSI, TW, TTMA
- Ports
- Female or male NPT
- Working pressure (bar)
- 25
Description — What this part number is, as the manufacturer lists it. Max flow — Maximum flow capacity in litres per minute, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Mount — Mounting flange or pattern, as published. Ports — Port type and size, as published. Ask us for the dimension drawing if you need it stamped.
Working pressure is the manufacturer’s published rating for the fitting itself. An assembly is limited by its lowest-rated component, so check it against the hose, the tube and the port you are mating to.
What is the MannTek CBC breaking-bolt cryogenic breakaway coupling used for?▾
How do I read the MannTek CBC part numbers?▾
Which sizes does the MannTek CBC come in?▾
What pressure and temperature is the MannTek CBC rated for?▾
Industrial or marine MannTek CBC: which version do I need?▾
How is the breaking load of the MannTek CBC set?▾
What connections does the MannTek CBC take?▾
What happens after the MannTek CBC releases?▾
What do I need to tell Indus to quote the MannTek CBC breakaway couplings?▾
How does the breaking-bolt CBC compare with the CBC-C?▾
Does Indus buy the MannTek CBC direct from the maker?▾
Are MannTek CBC breakaway couplings in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this part
Safety & HSE
How to choose a safety breakaway coupling: breaking bolt, cable release, industrial or marine
A safety breakaway coupling is the planned weak link in a hose line: when a truck drives off or a vessel moves, it separates and both halves close before the hose or arm is torn off. The three types, how to tell industrial from marine, how the breaking load is set, and where powered release takes over.
3 min read
Industrial hose
LNG bunkering couplings: ISO 21593 vs ISO/TS 18683, breakaways and emergency release
An LNG bunkering line is a chain: the dry cryogenic coupling, a breakaway or powered emergency release coupling, the transfer hose and the gear that holds and protects it. How the two coupling standards differ, how emergency release is staged as vessels move apart, and what goes around the hose string.
3 min read