MannTek DCC Dry Cryogenic Coupling for LNG, Hose Unit — 1" to 8"

MannTek DCC hose unit: the moving half of a dry cryogenic coupling, with integrated swivel and handles, for LNG and liquid-gas hoses and loading arms down to -196 °C. DCC to ISO/TS 18683 or DCC ISO to ISO 21593. From Indus Hydraulics, authorised MannTek distributor, UAE.
Key features
- Coupling Family: Dry Cryogenic Coupling
- Coupling Type / Variant: Hose unit (moving half, with swivel)
- End A Configuration: DCC bayonet interface to ISO/TS 18683, or DCC ISO interface to ISO 21593, with valve
- End B Configuration: NPT thread, or ANSI / EN flange
- Size Range: DCC DN 25 to DN 150; DCC ISO 1" to 8" (socket Ø 56 to 238 mm up to 6")
- Coupling Family
- Dry Cryogenic Coupling
- Coupling Type / Variant
- Hose unit (moving half, with swivel)
- End A Configuration
- DCC bayonet interface to ISO/TS 18683, or DCC ISO interface to ISO 21593, with valve
- End B Configuration
- NPT thread, or ANSI / EN flange
- Size Range
- DCC DN 25 to DN 150; DCC ISO 1" to 8" (socket Ø 56 to 238 mm up to 6")
Product description
The hose unit is the moving half of a MannTek Dry Cryogenic Coupling (DCC). It has an integrated swivel and handles and is fitted to hose assemblies and loading arms for temporary connection between a storage tank and a mobile transport unit. Push and turn, and the valves in both halves open for free flow; turn and pull, and both close before the coupling separates. The valve cannot be opened until the unit is coupled.
MannTek designs the DCC for cryogenic liquefied gases (LNG, nitrogen, oxygen, argon and ethylene) down to -196 °C. It uses the same bayonet principle and self-sealing valve design as MannTek's Dry Disconnect Couplings. Unlike a flanged or threaded joint, it needs no retightening during the cool-down phase. MannTek reports more than 10,000 connect and disconnect cycles in cryogenic testing.
Two interface standards
- DCC, to ISO/TS 18683 (ASTM F3312): DN 25 to DN 150. MannTek recommends it for existing installations and for most land-based LNG work, and it covers a wider range of transfer jobs outside marine bunkering.
- DCC ISO, to ISO 21593: 1" to 8". ISO 21593 is the international standard for dry couplings in ship-to-ship LNG bunkering, written for cross-manufacturer compatibility at sea.
Both versions are rows in the Sizes & Part Numbers tab. Choose the one that matches the other half, or the standard your terminal or vessel specifies.
Sizes and connections
Sockets from Ø 56 mm (1") to Ø 238 mm (6"), with 8" in the DCC ISO version. Connections are NPT thread or ANSI or EN flange. MannTek publishes flow capacity from 250 L/min at 1" to 24,000 L/min at 8".
Construction
- Body: stainless steel, weight optimised
- Seals: PTFE
- Integrated swivel, so the hose does not twist as the coupling is turned
- Powerful handle, with alternatives for specific uses
- Inner cam curve, protected from external impact; serviced without special tools
- Service temperature down to -196 °C; working pressure confirmed with the quotation
Where it is used
Container discharge; LNG bunkering truck-to-ship, ship-to-ship and terminal-to-ship; loading and unloading of tank trucks, rail tankers and ships; vapour recovery lines. MannTek also lists the DCC among its carbon capture solutions.
Options and accessories
MannTek builds the DCC hose unit with these options:
- Colour coding: body, flange and handles in any colour, so each coupling is clearly matched to its medium.
- Stop before disconnect: if a valve in either half fails to seal, because of damage or a foreign body, a patented blocking function stops the halves being separated, so the operator is not exposed to the medium.
- Hose unit with electronic sensor: reports whether the valves are open or closed, to start the transfer or to feed a drive-away interlock, with no change to the tank unit.
- Locking device: once coupled, the connection locks automatically and cannot loosen by accident, with no change to the tank unit.
- Special handles made for the application.
- Dust caps and dust plugs to keep dirt and water off the coupling faces.
- Heated parking device that defrosts and dries the hose unit after an LNG transfer, so it is ready again within minutes.
- Parking device for safe, dedicated storage of the hose unit, with or without a parking sensor.
Options for the tank unit are listed on its own page. Name the options you need when you ask for a quotation and we confirm the MannTek build.
Indus Hydraulics is an authorised MannTek distributor in the UAE and supplies MannTek couplings direct from MannTek in Sweden.
How to order
Send the size, the version (DCC to ISO/TS 18683 or DCC ISO to ISO 21593), the connection (NPT thread size, or flange standard and rating), the medium and its temperature, and list any options. We confirm the MannTek order code, price and lead time with the quotation.
Identification
| Parameter | Value |
|---|---|
| Coupling Family | Dry Cryogenic Coupling |
| Coupling Type / Variant | Hose unit (moving half, with swivel) |
| Notes | For LNG and cryogenic liquefied gases down to -196 °C. Working pressure and order code confirmed with the quotation. |
| Manufacturer | MannTek (Mann Teknik AB), Mariestad, Sweden |
Configuration
| Parameter | Value |
|---|---|
| End A Configuration | DCC bayonet interface to ISO/TS 18683, or DCC ISO interface to ISO 21593, with valve |
| End B Configuration | NPT thread, or ANSI / EN flange |
Dimensions
| Parameter | Value |
|---|---|
| Size Range | DCC DN 25 to DN 150; DCC ISO 1" to 8" (socket Ø 56 to 238 mm up to 6") |
Construction
| Parameter | Value |
|---|---|
| Materials Available | Stainless steel |
| Seal / Gasket | PTFE |
Compliance
| Parameter | Value |
|---|---|
| Applicable Standards | ISO/TS 18683 (ASTM F3312) or ISO 21593, by version |
Performance
| Parameter | Value |
|---|---|
| Flow capacity | 250 L/min (1") to 24,000 L/min (8"), as published by MannTek |
| Service temperature | Down to -196 °C |
Shipping & lead time
Sizes & part numbers
13 sizes- Indus part no.IH-MNT-DCC-HU-025
- Description
- DCC, ISO/TS 18683 interface. Body: stainless steel. E.g. LNG refuelling or vapour return lines
- Body size
- Ø 56 mm
- Nominal size
- 1" (DN 25)
- Max flow (L/min)
- 250
- Mount
- ANSI, EN
- Ports
- NPT
- Indus part no.IH-MNT-DCC-HU-050
- Description
- DCC, ISO/TS 18683 interface. Body: stainless steel. E.g. heavy-vehicle refuelling, tank truck and container cargo transfer
- Body size
- Ø 70 mm
- Nominal size
- 2" (DN 50)
- Max flow (L/min)
- 900
- Mount
- ANSI, EN
- Ports
- NPT
- Indus part no.IH-MNT-DCC-HU-065
- Description
- DCC, ISO/TS 18683 interface. Body: stainless steel. E.g. tank trucks, containers, smaller truck-to-ship or shore-to-ship bunkering
- Body size
- Ø 105 mm
- Nominal size
- 2-1/2" (DN 65)
- Max flow (L/min)
- 2,100
- Mount
- ANSI, EN
- Ports
- NPT
- Indus part no.IH-MNT-DCC-HU-080
- Description
- DCC, ISO/TS 18683 interface. Body: stainless steel. E.g. tank trucks, rail tankers, containers, smaller bunkering
- Body size
- Ø 119 mm
- Nominal size
- 3" (DN 80)
- Max flow (L/min)
- 2,800
- Mount
- ANSI, EN
- Ports
- NPT
- Indus part no.IH-MNT-DCC-HU-100
- Description
- DCC, ISO/TS 18683 interface. Body: stainless steel. E.g. high-volume transfer, truck-to-ship, ship-to-ship, shore-to-ship
- Body size
- Ø 164 mm
- Nominal size
- 4" (DN 100)
- Max flow (L/min)
- 7,000
- Mount
- ANSI, EN
- Ports
- NPT
- Indus part no.IH-MNT-DCC-HU-150
- Description
- DCC, ISO/TS 18683 interface. Body: stainless steel. E.g. marine bunkering, ship-to-ship or shore-to-ship cargo transfer
- Body size
- Ø 238 mm
- Nominal size
- 6" (DN 150)
- Max flow (L/min)
- 14,000
- Mount
- ANSI, EN
- Ports
- NPT
- Indus part no.IH-MNT-DCC-HU-ISO-025
- Description
- DCC ISO, ISO 21593 interface. Body: stainless steel
- Body size
- Ø 56 mm
- Nominal size
- 1" (DN 25)
- Max flow (L/min)
- 250
- Mount
- ANSI, EN
- Ports
- NPT
- Indus part no.IH-MNT-DCC-HU-ISO-050
- Description
- DCC ISO, ISO 21593 interface. Body: stainless steel
- Body size
- Ø 70 mm
- Nominal size
- 2" (DN 50)
- Max flow (L/min)
- 900
- Mount
- ANSI, EN
- Ports
- NPT
Show all 13 sizesShow fewer sizes
- Indus part no.IH-MNT-DCC-HU-ISO-065
- Description
- DCC ISO, ISO 21593 interface. Body: stainless steel
- Body size
- Ø 105 mm
- Nominal size
- 2-1/2" (DN 65)
- Max flow (L/min)
- 2,100
- Mount
- ANSI, EN
- Ports
- NPT
- Indus part no.IH-MNT-DCC-HU-ISO-080
- Description
- DCC ISO, ISO 21593 interface. Body: stainless steel
- Body size
- Ø 119 mm
- Nominal size
- 3" (DN 80)
- Max flow (L/min)
- 2,800
- Mount
- ANSI, EN
- Ports
- NPT
- Indus part no.IH-MNT-DCC-HU-ISO-100
- Description
- DCC ISO, ISO 21593 interface. Body: stainless steel
- Body size
- Ø 164 mm
- Nominal size
- 4" (DN 100)
- Max flow (L/min)
- 7,000
- Mount
- ANSI, EN
- Ports
- NPT
- Indus part no.IH-MNT-DCC-HU-ISO-150
- Description
- DCC ISO, ISO 21593 interface. Body: stainless steel
- Body size
- Ø 238 mm
- Nominal size
- 6" (DN 150)
- Max flow (L/min)
- 14,000
- Mount
- ANSI, EN
- Ports
- NPT
- Indus part no.IH-MNT-DCC-HU-ISO-200
- Description
- DCC ISO, ISO 21593 interface. Body: stainless steel
- Body size
- —
- Nominal size
- 8" (DN 200)
- Max flow (L/min)
- 24,000
- Mount
- ANSI, EN
- Ports
- NPT
Description — What this part number is, as the manufacturer lists it. Body size — Nominal body size of the coupling, which sets which halves mate. Max flow — Maximum flow capacity in litres per minute, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Mount — Mounting flange or pattern, as published. Ports — Port type and size, as published. Ask us for the dimension drawing if you need it stamped.
What is the MannTek DCC hose unit used for?▾
How do I read the MannTek DCC hose unit part numbers?▾
Which sizes does the MannTek DCC hose unit come in?▾
What temperature and pressure applies to the MannTek DCC?▾
What is the difference between the DCC and the DCC ISO?▾
Which gases can the MannTek DCC handle?▾
What connections and options does the MannTek DCC hose unit have?▾
Does the MannTek DCC need retightening as it cools down?▾
What do I need to tell Indus to quote the MannTek DCC hose units?▾
How does the DCC hose unit differ from the DCC tank unit?▾
Does Indus buy the MannTek DCC direct from the maker?▾
Are MannTek DCC hose units in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations