Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m, 3 t WLL, EN 13155

Modular lattice spreader beams rated 3 t and 6 t for very long, light loads: up to 44 m long with up to 44 lifting connections along the beam. For cladding panels, pipe and structural members.
Key features
- Product type: Lattice spreader beam
- Pattern / standard: EN 13155
- Size range: Loads up to 44 m long
- Working load limit: 3 t or 6 t
- Product type
- Lattice spreader beam
- Material
- Steel lattice, bolted modular sections
Product description
A light modular lattice beam for loads that are long rather than heavy. Lattice sections bolt together to the length of the load, and the load hangs from connections along the beam rather than from two ends, so a long flexible item is supported along its length instead of sagging between two points.
Sizes
| Part number | WLL | Load length | Lifting connections |
|---|---|---|---|
| IH-LR-BH-LSB-3 | 3 t | up to 44 m | up to 44 |
| IH-LR-BH-LSB-6 | 6 t | up to 44 m | up to 44 |
The WLL is the total load on the beam. How it shares between the connections depends on the rig, so the rigging is agreed with the order.
Why a lattice
A long load lifted at only two points bends between them, and a solid spreader long enough to avoid that is heavy. A lattice girder is stiff for its weight, so a beam tens of metres long stays light enough to handle with the crane that lifts the load. Sections bolt together, so the same kit builds a short beam for one job and a long one for the next, and breaks down for transport.
Rigging
The beam hangs from top slings to the hook and the load hangs from drop slings at the connection points, set at the spacing the load needs. Keep every drop sling vertical, and keep the top sling angle within the limit given in the user instructions.
Typical loads
- Long cladding and façade panels
- Pipe spools and long pipe
- Steel sections and trusses
- Blades, masts and other long, flexible items, with cradles
Ordering
Send the load length, weight and the points it may be lifted from. Beams for larger capacities and with cradles for blades are built to order.
Identification
| Parameter | Value |
|---|---|
| Product type | Lattice spreader beam |
| Pattern / standard | EN 13155 |
| Sizes | 2 |
Performance
| Parameter | Value |
|---|---|
| Working load limit | 3 t or 6 t |
Dimensions
| Parameter | Value |
|---|---|
| Size range | Loads up to 44 m long |
| Lifting connections | Up to 44 |
Construction
| Parameter | Value |
|---|---|
| Material | Steel lattice, bolted modular sections |
Compliance
| Parameter | Value |
|---|---|
| Certification | Declaration of conformity; user instructions |
Shipping & lead time
Sizes & part numbers
2 sizes- Indus part no.IH-LR-BH-LSB-3
- WLL (t)
- 3
- Length
- Loads up to 44 m
- Indus part no.IH-LR-BH-LSB-6
- WLL (t)
- 6
- Length
- Loads up to 44 m
WLL — Working load limit — the most the part may carry in service, as the manufacturer rates it. Length — Length as published. Ask us for the dimension drawing if you need it stamped.
WLL is the most the part may carry in service. Proof and breaking loads are test figures — never lift to them. Each load is shown in the unit the manufacturer rates the part in, and a size ships with the manufacturer’s test certificate.
What is the Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m used for?▾
How do I read the Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m part numbers IH-LR-BH-LSB-3 and IH-LR-BH-LSB-6?▾
How long a load can the Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m lift?▾
When do I need a lattice beam instead of a solid spreader?▾
What is the working load limit of the Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m?▾
What are the Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m made of?▾
What standard and documents apply to the Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m?▾
How is the Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m rigged?▾
What loads can the Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m lift?▾
How does the Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m compare with a modular spreader beam?▾
Can you ship the Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m outside the UAE?▾
What is the lead time on the Lattice Spreader Beams — 3 t and 6 t, Loads to 44 m?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Lifting & rigging
Spreader beam vs lifting beam: how each carries the load, and how to choose
A lifting beam hangs from one top point and carries the load in bending. A spreader beam hangs from two top slings and only holds them apart, in compression. That one difference decides the weight of the beam, the headroom it needs and the loads it suits.
7 min read
Lifting & rigging
Sling angle compression force: why an angled sling pulls harder, and what it does to the load
An angled sling has to pull sideways as well as up, so it always carries more than its share of the weight. The sideways part squeezes the load between the lifting points. How to find both forces with one triangle, the mistake that doubles the compression, and how a spreader beam takes it out of the load.
6 min read
Lifting & rigging
Spreader beam misuse: seven rigging errors that turn a spreader into a hazard
A spreader beam is designed for one load case: vertical drops at its ends, angled top slings, compression in between. Change the rigging and the forces change with it — the beam can end up doing nothing, being pulled apart, bent, or overloaded at one end. Seven common errors, why each matters, and how to spot them before the lift.
6 min read