Hose Mender

Hose Mender — hose mender with a serrated tail at each end. Sizes 1/2"–12". Carbon Steel, SS304, & SS316. Supplied by Sunpool (Taiwan); RFQ-only via Indus Hydraulics authorised distribution.
Key features
- Coupling Family: KC Nipple / Industrial Hose Fitting
- Coupling Type / Variant: KC Nipple & Hose Fitting — Hose Mender
- End A Configuration: Serrated hose tail
- End B Configuration: Serrated hose tail
- Size Range: 1/2"-12"
- Coupling Family
- KC Nipple / Industrial Hose Fitting
- Coupling Type / Variant
- KC Nipple & Hose Fitting — Hose Mender
- End A Configuration
- Serrated hose tail
- End B Configuration
- Serrated hose tail
- Size Range
- 1/2"-12"
Product description
The Hose Mender is a KC Nipple / Industrial Hose Fitting from the Sunpool (Taiwan) industrial coupling range. Indus Hydraulics is an authorised distributor in the UAE.
Configuration
- Coupling family: KC Nipple / Industrial Hose Fitting
- Coupling type: KC Nipple & Hose Fitting — Hose Mender
- End A: Serrated hose tail
- End B: Serrated hose tail
Specifications
- Size range: 1/2"–12"
- Material: Carbon Steel, SS304, & SS316
- Working pressure: Not published by Sunpool. Give us your working pressure and medium and we will check it with the manufacturer.
Manufacturer notes
- High quality carbon steel provides durable life.
- Extra fine machining serrated tail.
- Excellent shining plated surface.
About the family
KC (king combination) nipples are hose tails: a serrated shank that goes inside the hose, and a threaded, grooved or flanged end that connects to pipe or another fitting. The hose is held on the tail by a clamp, ferrule or sleeve, and that is what sets how much pressure the joint holds. Sunpool makes standard KC nipples from 1/2" to 12" in plated carbon steel, SS304 and SS316; heavy-duty versions with a thicker wall and a longer tail for crimping with a ferrule, with or without a welded #150 flange; grooved nipples for rigid grooved couplings; and hose menders. The same shelf carries large-bore fittings for agricultural drag hose and frac-water lines, a Figure 206 hammer-union hose coupling and suction hose couplings.
Selection and service notes
The clamp, ferrule or sleeve over the hose usually limits the assembly, not the nipple: rate the joint at its weakest part. Sunpool rates its heavy-duty KC nipples and flanges at 300 psi and publishes no rating for the rest. Specify the end thread and give the hose outside diameter for the ferrule or sleeve.
How to order
Specify the size, the body material where more than one is listed, and any thread, tail or gasket variant on the RFQ. Indus engineering will confirm the manufacturer part number against your application.
Further reading: KC nipples, shank couplings and hose menders.
Sunpool sizes
Order by the Indus part number in the size table or by the Sunpool part number for the material you need.
| Size | Sunpool part no., carbon steel (plated) | SS304 | SS316 |
|---|---|---|---|
| 1/2" | HM-CS-050 | HM-S4-050 | HM-S6-050 |
| 3/4" | HM-CS-075 | HM-S4-075 | HM-S6-075 |
| 1" | HM-CS-100 | HM-S4-100 | HM-S6-100 |
| 1-1/4" | HM-CS-125 | HM-S4-125 | HM-S6-125 |
| 1-1/2" | HM-CS-150 | HM-S4-150 | HM-S6-150 |
| 2" | HM-CS-200 | HM-S4-200 | HM-S6-200 |
| 2-1/2" | HM-CS-250 | HM-S4-250 | HM-S6-250 |
| 3" | HM-CS-300 | HM-S4-300 | HM-S6-300 |
| 4" | HM-CS-400 | HM-S4-400 | HM-S6-400 |
| 5" | HM-CS-500 | HM-S4-500 | HM-S6-500 |
| 6" | HM-CS-600 | HM-S4-600 | HM-S6-600 |
| 8" | HM-CS-800 | HM-S4-800 | HM-S6-800 |
| 10" | HM-CS-1K | HM-S4-1K | HM-S6-1K |
| 12" | HM-CS-1K2 | HM-S4-1K2 | HM-S6-1K2 |
Sizes and part numbers from Sunpool’s catalogue page for this part and its KC part-number list, checked 7 October 2026.
Identification
| Parameter | Value |
|---|---|
| Coupling Family | KC Nipple / Industrial Hose Fitting |
| Coupling Type / Variant | KC Nipple & Hose Fitting — Hose Mender |
Configuration
| Parameter | Value |
|---|---|
| End A Configuration | Serrated hose tail |
| End B Configuration | Serrated hose tail |
Dimensions
| Parameter | Value |
|---|---|
| Size Range | 1/2"-12" |
Construction
| Parameter | Value |
|---|---|
| Materials Available | Carbon Steel, SS304, & SS316 |
Notes
| Parameter | Value |
|---|---|
| Notes | High quality carbon steel provides durable life. Extra fine machining serrated tail. Excellent shining plated surface. |
Shipping & lead time
Sizes & part numbers
14 sizes- Indus part no.IH-KC-HOSE-MENDER-050
- Nominal size
- 1/2"
- Indus part no.IH-KC-HOSE-MENDER-075
- Nominal size
- 3/4"
- Indus part no.IH-KC-HOSE-MENDER-100
- Nominal size
- 1"
- Indus part no.IH-KC-HOSE-MENDER-125
- Nominal size
- 1-1/4"
- Indus part no.IH-KC-HOSE-MENDER-150
- Nominal size
- 1-1/2"
- Indus part no.IH-KC-HOSE-MENDER-200
- Nominal size
- 2"
- Indus part no.IH-KC-HOSE-MENDER-250
- Nominal size
- 2-1/2"
- Indus part no.IH-KC-HOSE-MENDER-300
- Nominal size
- 3"
Show all 14 sizesShow fewer sizes
- Indus part no.IH-KC-HOSE-MENDER-400
- Nominal size
- 4"
- Indus part no.IH-KC-HOSE-MENDER-500
- Nominal size
- 5"
- Indus part no.IH-KC-HOSE-MENDER-600
- Nominal size
- 6"
- Indus part no.IH-KC-HOSE-MENDER-800
- Nominal size
- 8"
- Indus part no.IH-KC-HOSE-MENDER-1000
- Nominal size
- 10"
- Indus part no.IH-KC-HOSE-MENDER-1200
- Nominal size
- 12"
What is the hose mender used for?▾
How do I read the hose mender part numbers?▾
What sizes does the hose mender come in?▾
What working pressure does the hose mender have?▾
What is the hose mender made of?▾
Does Indus supply test certificates with the hose mender?▾
What does the hose mender connect to?▾
How do I fit the hose mender to a hose?▾
Where is the hose mender typically used?▾
How does the hose mender differ from the KC nipple?▾
Where is the hose mender made, and is it stocked?▾
Is the hose mender in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this part
Industrial hose
How to repair lay flat hose: cutting out, re-coupling and menders
A cut, a burst fold or a crushed coupling does not have to mean a new hose. Most lay flat damage is repaired by cutting out the bad section and re-coupling, or — on low-pressure lines — joining the ends with a mender. When to repair and when to scrap, how to make each repair properly, and the extra rules that apply to fire hose.
4 min read
Industrial hose
Why lay flat hose fails: bursts, kinks, abrasion and how to prevent them
Lay flat hose rarely fails because it was too weak on paper. It fails at a kink, along a worn fold, at a coupling that crept, after a pressure surge, or because it was used on a pump suction. Here are the eight common failure modes, how to read the evidence on a failed hose, and the handling and inspection habits that prevent them.
6 min read