Yuken DSG-01-2B2-D24-50 Solenoid Directional Valve, 4/2 Spring-Offset, 24 V DC
Category image · Valves & ManifoldsYuken DSG-01-2B2-D24-50: a 4/2 spring-offset directional valve with a single 24 V DC solenoid on the b side, for the ISO 4401-03 (CETOP 3) interface. Design 50 is rated 315 kgf/cm² and 63 L/min.
Key features
- Flow rate (max): 63 L/min
- Pressure (max): 309 bar
Product description
The Yuken DSG-01-2B2-D24-50 is a two-position, spring-offset directional valve for sub-plate mounting on the ISO 4401-03 interface (CETOP 3, NG6). One solenoid shifts the spool; when it is switched off, the spring returns the spool to its offset position.
The model code
- DSG — solenoid-operated directional valve, sub-plate mounted
- 01 — size 01, ISO 4401-03 mounting surface
- 2B — two positions, spring offset, one solenoid, on the b side as standard
- 2 — spool type 2
- D24 — 24 V DC coil
- 50 — design number
In Yuken's vent-type table a DSG-01-2B2 connects P to port A when de-energised and P to port B when solenoid b is energised. An L suffix moves the solenoid to the a side. Yuken also uses the 2B2 as the pilot valve on its BSG solenoid-controlled relief valves, to switch between pressure settings.
Ratings (design 50)
- Maximum operating pressure: 315 kgf/cm² (about 31 MPa)
- Maximum flow: 63 L/min. With a DC coil, spool 2B2 passes 63 L/min four-way from 50 to 315 kgf/cm².
- Maximum tank-line back pressure: 160 kgf/cm²
- Coil: 24 V DC, 1.1 A, 26 W
- Mass: 1.6 kg
Design 50 and design 70
Yuken India builds the DSG-01 to design 50; Yuken in Japan has moved to design 70, which fits the same mounting surface with a different outline and is rated 35 MPa and 100 L/min, with a 29 W coil and a mass of 1.4 kg. Say which you need, or send the nameplate of the valve you are replacing.
Ordering
Give the full model code, the design number, the coil voltage and the solenoid side (L for the a side) on your RFQ. We supply new valves and confirm lead time on the quotation.
Performance
| Parameter | Value |
|---|---|
| Function | 4/2 directional, spring offset, single solenoid (b side) |
| Flow rate (max) | 63 L/min |
| Pressure (max) | 309 bar |
| Spool | 2B2 — P to A off, P to B with solenoid b on |
| Max operating pressure (as published) | 315 kgf/cm² (design 50) |
| Max tank-line back pressure | 160 kgf/cm² (design 50) |
| Max changeover frequency | 300 cycles/min (DC coil) |
Mechanical
| Parameter | Value |
|---|---|
| CETOP size | CETOP 3 (ISO 4401-03) |
| Weight | 1.6 kg |
Electrical
| Parameter | Value |
|---|---|
| Coil voltage | 24 V DC |
| Coil power | 26 W |
| Protection | IP65 equivalent |
Identification
| Parameter | Value |
|---|---|
| Model code | DSG-01-2B2-D24-50 |
Shipping & lead time
What is the Yuken DSG-01-2B2-D24-50 Solenoid Directional Valve, 4/2 Spring-Offset, 24 V DC?▾
What does the Yuken model code DSG-01-2B2-D24-50 mean?▾
How much flow and pressure can the Yuken DSG-01-2B2 take?▾
What is the difference between design 50 and design 70 of the Yuken DSG-01?▾
What coil does the Yuken DSG-01-2B2-D24-50 have?▾
Which way does the oil flow in the Yuken DSG-01-2B2?▾
Does the Yuken DSG-01-2B2 hold a cylinder in position?▾
Which sub-plates fit the Yuken DSG-01-2B2?▾
How is the Yuken DSG-01-2B2 mounted and what oil does it need?▾
Where is the Yuken DSG-01-2B2 used?▾
How does the Yuken DSG-01-2B2 differ from the DSG-01-3C4 valve?▾
How do I order the Yuken DSG-01-2B2-D24-50 solenoid valve?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Oilfield & pressure control
DEMCO butterfly valve part numbers decoded: series, size, body, stem, disc and seat
A DEMCO butterfly valve number such as J022122-1215311 spells out the valve: series and size in the base, then body style, body, stem, disc and seat in the suffix. How to read one, and when to trust the nameplate instead.
5 min read
Oilfield & pressure control
Butterfly valves: wafer, lug or grooved, shut-off ratings and dead-end service
A butterfly valve is the cheapest, lightest way to isolate a large line — but the body style decides what it can do. A wafer valve is clamped between two flanges and cannot hold pressure with one side removed; a lug valve can, within limits the maker sets; a grooved valve joins grooved pipe without flanges at all. How the DEMCO NE-C, NE-I, NE-D and NF-C series and the Victaulic grooved valves differ, what their shut-off ratings mean, and how to choose the handle or gear — and where concentric, double offset and triple offset valves to API 609 take over.
8 min read
Cylinders, pumps & motors
Hydraulic control valves: directional, relief, flow control and flow dividers explained
A hydraulic circuit is steered by a handful of valve types: a directional valve that sends oil to one side of a cylinder or the other, a relief valve that caps the pressure, flow controls and dividers that set speed, and check and selector valves that hold or route the flow. How monoblock spool valves, CETOP 3 solenoid valves and modular stacks work, what open and closed centre mean, and what to send to get the right replacement.
5 min read