Yuken BG-03 Pilot Operated Relief Valve, up to 24.5 MPa, 100 L/min
Category image · Valves & ManifoldsYuken BG-03 pilot operated relief valve for sub-plate mounting on the ISO 6264 interface: settable up to 250 kgf/cm² (about 24.5 MPa), 100 L/min, with a vent port for remote setting or pump unloading. Model code BG-03-32.
Key features
- Flow rate (max): 100 L/min
- Pressure (max): 250 bar
Product description
The Yuken BG-03 is a pilot operated relief valve for sub-plate mounting. It protects pumps and control valves from excess pressure and holds system pressure at its setting. Through its vent port it can also be set remotely, or used to unload the pump.
The model code
- B — pilot operated relief valve
- G — sub-plate (gasket) mounting; T would be a threaded body
- 03 — size 03
- 32 — design number
The code carries no pressure field: one valve covers the full range. Add V before the design number (BG-03-V-32) for the high-vent type, which switches back from unloading to load faster, at the cost of higher minimum and vent pressures. An F- prefix is for phosphate-ester fluid.
Ratings
- Maximum operating pressure: 250 kgf/cm² (about 24.5 MPa)
- Maximum flow: 100 L/min; at least 8 L/min for a stable setting
- Mounting surface: ISO 6264-AR-06-2-A
- Mass: 4.7 kg
- Oil: 15–400 mm²/s, −15 to +70 °C
Sub-plates and installation
Yuken's sub-plates are BGM-03 (3/8 BSP) and BGM-03X (1/2 BSP); the valve is held by two M12 × 70 and two M12 × 95 bolts. Collars under the adjusting handle cap the settable pressure, about 10 MPa each, so remove one if the setting you need cannot be reached. Run the tank line straight to the reservoir rather than into other valves' tank lines, or the setting becomes unstable.
Ordering
Quote BG-03-32, or BG-03-V-32 for the high-vent type, with the sub-plate if you need one. We supply new valves and confirm lead time on the quotation.
Performance
| Parameter | Value |
|---|---|
| Function | Pilot operated relief valve, sub-plate mounted |
| Flow rate (max) | 100 L/min |
| Pressure (max) | 250 bar |
| Minimum flow | 8 L/min for a stable setting |
| Pressure change per turn | About 5 MPa |
Mechanical
| Parameter | Value |
|---|---|
| Weight | 4.7 kg |
| Mounting surface | ISO 6264-AR-06-2-A |
| Sub-plates | BGM-03 (3/8 BSP), BGM-03X (1/2 BSP) |
Identification
| Parameter | Value |
|---|---|
| Model code | BG-03-32 (BG-03-V-32 high-vent) |
Shipping & lead time
What is the Yuken BG-03 Pilot Operated Relief Valve, up to 24.5 MPa, 100 L/min used for?▾
What does the Yuken model code BG-03-32 mean, and what is the V version?▾
What pressure can the Yuken BG-03 relief valve be set to?▾
How much flow can the Yuken BG-03 relief valve take?▾
What oil and temperature can the Yuken BG-03 relief valve run on?▾
Which mounting surface does the Yuken BG-03 relief valve use?▾
Which sub-plates fit the Yuken BG-03 relief valve?▾
How should the Yuken BG-03 relief valve be piped and set?▾
What is the vent port on the Yuken BG-03 for?▾
How does the Yuken BG-03 relief valve differ from the DSG-01 directional valves?▾
What is the Yuken BG-03 relief valve made to protect, and how heavy is it?▾
How do I order the Yuken BG-03 pilot operated relief valve?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations