Yuken DSG-01-3C4-D24-50 Solenoid Directional Valve, 4/3 Spring-Centred, 24 V DC
Category image · Valves & ManifoldsYuken DSG-01-3C4-D24-50: a 4/3 spring-centred, double-solenoid directional valve on the ISO 4401-03 (CETOP 3) interface, with a 24 V DC, 26 W coil. Design 50 is rated 315 kgf/cm² and 63 L/min.
Key features
- Flow rate (max): 63 L/min
- Pressure (max): 309 bar
Product description
The Yuken DSG-01-3C4-D24-50 is a solenoid-operated directional valve for sub-plate mounting on the ISO 4401-03 interface, the size sold as CETOP 3 or NG6. Two solenoids shift the spool to start, stop and reverse a cylinder or motor, and springs return it to the centre when both are off.
The model code
- DSG — solenoid-operated directional valve, sub-plate mounted
- 01 — size 01, ISO 4401-03 mounting surface
- 3C — three positions, spring centred, two solenoids
- 4 — spool type 4
- D24 — 24 V DC coil, usable from 21.6 to 26.4 V
- 50 — design number
With no letter after the coil code the valve has a terminal box and a push-pin manual override; N or N1 in that place gives a DIN connector, N1 with an indicator lamp. In the centre position Yuken's flow tables give spool 4 no path from P to T, so the valve does not unload the pump; Yuken's centre-bypass spools are 5 and 60.
Ratings (design 50)
- Maximum operating pressure: 315 kgf/cm² (about 31 MPa)
- Maximum flow: 63 L/min. With a DC coil, spool 3C4 passes 63 L/min up to 250 kgf/cm² and 35 L/min at 315 kgf/cm².
- Maximum tank-line back pressure: 160 kgf/cm²
- Maximum changeover frequency: 300 cycles per minute
- Coil: 24 V DC, 1.1 A, 26 W; protection equivalent to IP65
- Mass: 2.2 kg
Design 50 and design 70
Yuken India builds the DSG-01 to design 50. Yuken in Japan has moved to design 70, which bolts to the same mounting surface but has a different outline and higher ratings: 35 MPa, 100 L/min, a 29 W coil and 1.85 kg. Say which you need, or send the nameplate of the valve you are replacing.
Installing it
The solenoids are wet-pin: the core tube fills with oil, which damps shock and noise, so the tank port must stay full of oil and must not see surge pressure. Four M5 × 45 socket-head screws hold it down. Yuken's manual gives a working oil viscosity of 15–400 mm²/s and an oil temperature of −15 to +70 °C.
Ordering
Give the full model code, the design number and the coil voltage on your RFQ, with the sub-plate if you need one. We supply new valves and confirm lead time on the quotation.
Performance
| Parameter | Value |
|---|---|
| Function | 4/3 directional, spring centred, double solenoid |
| Flow rate (max) | 63 L/min |
| Pressure (max) | 309 bar |
| Spool | 3C4 — no P-to-T path in centre |
| Max operating pressure (as published) | 315 kgf/cm² (design 50) |
| Max tank-line back pressure | 160 kgf/cm² (design 50) |
| Max changeover frequency | 300 cycles/min (DC coil) |
Mechanical
| Parameter | Value |
|---|---|
| CETOP size | CETOP 3 (ISO 4401-03) |
| Weight | 2.2 kg |
Electrical
| Parameter | Value |
|---|---|
| Coil voltage | 24 V DC |
| Coil power | 26 W |
| Protection | IP65 equivalent |
Identification
| Parameter | Value |
|---|---|
| Model code | DSG-01-3C4-D24-50 |
Shipping & lead time
What is the Yuken DSG-01-3C4-D24-50 Solenoid Directional Valve, 4/3 Spring-Centred, 24 V DC?▾
What does the Yuken model code DSG-01-3C4-D24-50 mean?▾
What does spool 4 do in the centre position of the Yuken DSG-01-3C4?▾
How much flow and pressure can the Yuken DSG-01-3C4 take?▾
What coil does the Yuken DSG-01-3C4-D24-50 have?▾
What is the difference between design 50 and design 70 of the Yuken DSG-01?▾
Does the Yuken DSG-01-3C4 hold a cylinder in position?▾
Which sub-plates fit the Yuken DSG-01-3C4?▾
How is the Yuken DSG-01-3C4 installed, and why must the tank port stay full?▾
Where is the Yuken DSG-01-3C4 used?▾
How does the Yuken DSG-01-3C4 differ from the DSG-01-2B2 valve?▾
How do I order the Yuken DSG-01-3C4-D24-50 solenoid valve?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations