Sun Hydraulics Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve — RVET, RVGT, RVIT, Series 2 to 4

Sun Hydraulics anti-shock pilot-operated relief valve: RVET, RVGT, RVIT, series 2 to 4, 30 gpm to 120 gpm (120 L/min to 480 L/min), T-2A, T-17A, T-19A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Anti-Shock Pilot-Operated Relief Valve
- Capacity: 30 gpm to 120 gpm (120 L/min to 480 L/min)
- Max operating pressure: 5000 psi (350 bar)
- Cavity: T-2A, T-17A, T-19A
- Valve function
- Anti-Shock Pilot-Operated Relief Valve
- Series (frame sizes)
- 2 to 4
- Cavity
- T-2A, T-17A, T-19A
Product description
A pilot-operated relief that caps maximum pressure and also limits how fast pressure rises. When a pressure spike arrives it opens, then closes again at a controlled rate set inside the valve, independent of the setting or flow. One adjustment sets both the maximum (relief) pressure and the threshold at which the cushioning starts.
Sizes and cavities
Sun Hydraulics builds this valve in 3 sizes. The series sets the cavity it screws into and its flow capacity:
- RVET — series 2, T-2A cavity, 30 gpm (120 L/min)
- RVGT — series 3, T-17A cavity, 60 gpm (240 L/min)
- RVIT — series 4, T-19A cavity, 120 gpm (480 L/min)
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Maximum operating pressure: 5000 psi (350 bar)
- Typical response time: 2 ms
Configuration options
The letters after the base model code choose these options (shown for RVIT; a size may add or drop a choice):
- Control: C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment
- Setting range: A — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, C — 1000 - 6000 psi (70 - 420 bar), 1000 psi (70 bar) Standard Setting, W — 1000 - 4500 psi (70 - 315 bar), 1000 psi (70 bar) Standard Setting
- Seal material: N — Buna-N, V — Viton
- Material / coating: /AP — Stainless Steel, Passivated
Option rules: If the modifier is /AP, the control must be C or L.
Selection notes
- Not suitable for load-holding duty.
- Accepts full pressure at port 2, so it suits cross-port relief circuits.
Where it is used
Cushioning hydraulic shock when actuators start or stop: slewing drives, winches, swing motors and cylinders with large moving masses.
Installation and seal kits
Valve hex 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 2: Buna: 990402007, Polyurethane: 990002002, Viton: 990402006; series 3: Buna: 990217007, Polyurethane: 990217002, Viton: 990217006; series 4: Buna: 990219007, Viton: 990219006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example RVITLAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Identification
| Parameter | Value |
|---|---|
| Valve function | Anti-Shock Pilot-Operated Relief Valve |
| Series (frame sizes) | 2 to 4 |
| Cavity | T-2A, T-17A, T-19A |
Performance
| Parameter | Value |
|---|---|
| Capacity | 30 gpm to 120 gpm (120 L/min to 480 L/min) |
| Max operating pressure | 5000 psi (350 bar) |
| Setting range | A — 500 - 3000 psi (35 - 210 bar), 1000 psi (70 bar) Standard Setting, C — 1000 - 6000 psi (70 - 420 bar), 1000 psi (70 bar) Standard Setting, W — 1000 - 4500 psi (70 - 315 bar), 1000 psi (70 bar) Standard Setting |
Configuration
| Parameter | Value |
|---|---|
| Control / adjustment | C — Tamper Resistant - Factory Set, K — Handknob, L — Standard Screw Adjustment |
| Seal material | N — Buna-N, V — Viton |
| Material / coating | /AP — Stainless Steel, Passivated |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm) |
| Installation torque | 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm) |
| Seal kits | series 2: Buna: 990402007, Polyurethane: 990002002, Viton: 990402006; series 3: Buna: 990217007, Polyurethane: 990217002, Viton: 990217006; series 4: Buna: 990219007, Viton: 990219006 |
| Weight | 1.60 lb (0,70 kg) to 3.10 lb (1,40 kg) |
Shipping & lead time
Sizes & part numbers
3 sizes- Sun Hydraulics part no.RVET
- Series
- 2
- Cavity
- T-2A
- Capacity
- 30 gpm / 120 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVGT
- Series
- 3
- Cavity
- T-17A
- Capacity
- 60 gpm / 240 L/min
- Max pressure
- 5000 psi / 350 bar
- Sun Hydraulics part no.RVIT
- Series
- 4
- Cavity
- T-19A
- Capacity
- 120 gpm / 480 L/min
- Max pressure
- 5000 psi / 350 bar
Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units. Max pressure — Maximum pressure as the maker publishes it, in psi and bar.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve (RVET, RVGT, RVIT) and what does it do?▾
How do I read the Sun model code for the Sun Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve (RVET, RVGT, RVIT)?▾
What sizes and flow capacities does the Sun Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve come in?▾
What pressure and setting range does the Sun Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve have?▾
Which seal and material options does the Sun Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve come with?▾
How is the Sun Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve adjusted, and which control options are offered?▾
Which seal kit fits the Sun Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve (RVET, RVGT, RVIT)?▾
Which cavity and installation torque does the Sun Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve need?▾
Where is the Sun Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve used?▾
How does the Sun RVET valve differ from the Sun Anti-Shock, Pilot-Operated, Balanced Poppet Relief Valve?▾
How is an anti-shock relief different from an ordinary relief valve on the Sun Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve?▾
Can I buy the Sun Anti-Shock, Ventable, Pilot-Operated, Balanced Poppet Relief Valve from stock in the UAE and get a quotation?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations