Skip to content
SUN HYDRAULICSIH-SUN-FV-A

Sun Hydraulics Ventable, Fixed-Orifice, Bypass/Restrictive, Priority Flow Control Valve — FVCA, FVDA, FVEA, FVFA, Series 1 to 4

Flow Control CartridgesEx-stock · delivery in 3 days
Sun Hydraulics FVCA ventable priority flow control valve, series 1, T-21A cavity — dimension drawing
VIEW 01·Sun Hydraulics FVCA ventable priority flow control valve, series 1, T-21A cavity — dimension drawing
1 / 3

Sun Hydraulics ventable priority flow control valve: FVCA, FVDA, FVEA, FVFA, series 1 to 4, 6 gpm to 50 gpm (23 L/min to 200 L/min), T-21A, T-22A, T-23A, T-24A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Ventable Priority Flow Control Valve
  • Capacity: 6 gpm to 50 gpm (23 L/min to 200 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-21A, T-22A, T-23A, T-24A
Valve function
Ventable Priority Flow Control Valve
Series (frame sizes)
1 to 4
Cavity
T-21A, T-22A, T-23A, T-24A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A fixed-orifice priority flow control with a vent port (port 4). A pressure control on the vent caps the pressure at the priority outlet; versions with an integral T-8A cavity let the priority flow be switched electrically, manually, hydraulically or by air, depending on the pilot cartridge fitted.

Sizes and cavities

Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:

  • FVCA — series 1, T-21A cavity, 6 gpm (23 L/min)
  • FVDA — series 2, T-22A cavity, 12 gpm (45 L/min)
  • FVEA — series 3, T-23A cavity, 25 gpm (95 L/min)
  • FVFA — series 4, T-24A cavity, 50 gpm (200 L/min)

Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)

Configuration options

The letters after the base model code choose these options (shown for FVCA; a size may add or drop a choice):

  • Control: L — Tuning Adjustment, X — Not Adjustable
  • Setting range: A — Replaceable Orifice .1 - 6 gpm (0,4 - 23 L/min.), B — Permanent Orifice .1 - 6 gpm (0,4 - 23 L/min.)
  • Seal material: N — Buna-N, V — Viton

Selection notes

  • Factory-set priority flow, within about ±10%.
  • If bypass pressure exceeds the vent setting, priority flow is shut off and all flow goes to bypass.

Where it is used

Priority circuits that must be switched or pressure-limited remotely.

Installation and seal kits

Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, EPDM: 990022014, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, EPDM: 990024014, Polyurethane: 990024002, Viton: 990024006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example FVCAXAN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.

Identification

ParameterValue
Valve functionVentable Priority Flow Control Valve
Series (frame sizes)1 to 4
CavityT-21A, T-22A, T-23A, T-24A

Performance

ParameterValue
Capacity6 gpm to 50 gpm (23 L/min to 200 L/min)
Max operating pressure5000 psi (350 bar)
Setting rangeA — Replaceable Orifice .1 - 6 gpm (0,4 - 23 L/min.), B — Permanent Orifice .1 - 6 gpm (0,4 - 23 L/min.)

Configuration

ParameterValue
Control / adjustmentL — Tuning Adjustment, X — Not Adjustable
Seal materialN — Buna-N, V — Viton

Installation

ParameterValue
Valve hex size7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm)
Installation torque30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm)
Seal kitsseries 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, EPDM: 990022014, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, EPDM: 990024014, Polyurethane: 990024002, Viton: 990024006
Weight.30 lb (0,15 kg) to 2.80 lb (1,30 kg)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

RELATED · OFTEN PAIRED WITH