Sun Hydraulics Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve — CBCHX, CBDHX, Series 1 to 2

Sun Hydraulics fixed-setting counterbalance valve, 10:1 pilot ratio: CBCHX, CBDHX, series 1 to 2, 7.5 gpm to 15 gpm (30 L/min to 60 L/min), T-11A, T-2A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.
Key features
- Valve function: Fixed-Setting Counterbalance Valve
- Capacity: 7.5 gpm to 15 gpm (30 L/min to 60 L/min)
- Max operating pressure: Max setting 5000 psi (350 bar)
- Cavity: T-11A, T-2A
- Valve function
- Fixed-Setting Counterbalance Valve
- Series (frame sizes)
- 1 to 2
- Cavity
- T-11A, T-2A
Product description
This is the 3-port counterbalance valve with its setting fixed at the factory instead of a field adjustment. The integral check gives free flow into the actuator (port 2 to port 1); the pilot-assisted relief stage holds the load (port 1 to port 2) until pilot pressure at port 3 opens it in proportion to the pilot ratio. With no adjusting screw it cannot be turned down in the field, and it sits lower than the adjustable version.
Sizes and cavities
Sun Hydraulics builds this valve in 2 sizes. The series sets the cavity it screws into and its flow capacity:
- CBCHX — series 1, T-11A cavity, 15 gpm (60 L/min), standard capacity
- CBDHX — series 2, T-2A cavity, 7.5 gpm (30 L/min), restrictive
Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.
Ratings
- Pilot ratio: 10:1
- Maximum setting: 5000 psi (350 bar)
- Maximum recommended load pressure at maximum setting: 3850 psi (270 bar)
- Maximum leakage: 5 drops/min. (0,3 cc/min)
- Check cracking pressure: 25 psi (1,7 bar)
Configuration options
The letters after the base model code choose these options (shown for CBCHX; a size may add or drop a choice):
- Setting range: M — 4700 - 5600 psi (325 - 390 bar), V — 3200 - 3800 psi (220 - 260 bar), X — 3500 - 4200 psi (245 - 290 bar), Z — 4125 - 4900 psi (285 - 340 bar)
- Seal material: N — Buna-N, V — Viton, E — EPDM
- Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel
Selection notes
- Ordered by pressure range: the valve is factory set to a nominal value within it.
- The range figures are approximate mean values, not inspection limits.
- Lower profile than the adjustable valve, with no screw or locknut to tamper with.
Where it is used
OEM machines where the setting must not be changed in service: aerial platforms, cranes and handling equipment built to a fixed load chart.
Installation and seal kits
Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm). Replacement seal kits — series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006.
Ordering
Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example CBCHXMN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.
Performance
| Parameter | Value |
|---|---|
| Capacity | 7.5 gpm to 15 gpm (30 L/min to 60 L/min) |
| Max operating pressure | Max setting 5000 psi (350 bar) |
| Pilot ratio | 10:1 |
| Setting range | M — 4700 - 5600 psi (325 - 390 bar), V — 3200 - 3800 psi (220 - 260 bar), X — 3500 - 4200 psi (245 - 290 bar), Z — 4125 - 4900 psi (285 - 340 bar) |
| Max leakage | 5 drops/min. (0,3 cc/min) |
Installation
| Parameter | Value |
|---|---|
| Valve hex size | 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm) |
| Installation torque | 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm) |
| Seal kits | series 1: Buna: 990011007, Polyurethane: 990011002, Viton: 990011006; series 2: Buna: 990202007, Polyurethane: 990002002, Viton: 990202006 |
| Weight | .35 lb (0,15 kg) to .60 lb (0,30 kg) |
Identification
| Parameter | Value |
|---|---|
| Valve function | Fixed-Setting Counterbalance Valve |
| Series (frame sizes) | 1 to 2 |
| Cavity | T-11A, T-2A |
Configuration
| Parameter | Value |
|---|---|
| Seal material | N — Buna-N, V — Viton, E — EPDM |
| Material / coating | /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel |
Shipping & lead time
Sizes & part numbers
2 sizes- Sun Hydraulics part no.CBCHX
- Description
- Standard capacity
- Series
- 1
- Cavity
- T-11A
- Capacity
- 15 gpm / 60 L/min
- Sun Hydraulics part no.CBDHX
- Description
- Restrictive
- Series
- 2
- Cavity
- T-2A
- Capacity
- 7.5 gpm / 30 L/min
Description — What this part number is, as the manufacturer lists it. Series — Frame size the cartridge is built in, as the maker numbers it; one series shares one cavity size. Cavity — Cavity the cartridge screws into, as the maker designates it. Capacity — Rated flow capacity as published, in US and metric units.
Part numbers are the maker’s base model codes. The full ordering code adds letters for the control, setting range, seal and material options, and we confirm it with the quotation. Capacity and pressure are the maker’s published ratings for the cartridge; check them against the cavity body and the rest of the circuit.
What is the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve (CBCHX, CBDHX) and what does it do?▾
How do I read the Sun model code for the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve (CBCHX, CBDHX)?▾
What sizes and flow capacities does the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve come in?▾
What pressure and setting range does the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve have?▾
Which seal and material options does the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve come with?▾
How is the setting of the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve chosen?▾
Which seal kit fits the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve (CBCHX, CBDHX)?▾
Which cavity and installation torque does the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve need?▾
Where is the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve used?▾
How does the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve differ from the Sun Fixed-Setting 1.5:1 Pilot Ratio Counterbalance Valve?▾
Should I choose the biggest capacity that fits on the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve?▾
Do you stock the Sun Fixed-Setting 10:1 Pilot Ratio Counterbalance Valve in Dubai for export?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations