Skip to content
SUN HYDRAULICSIH-SUN-CW-L

Sun Hydraulics 2:1 Pilot Ratio Vented Counterbalance Valve — CWCL, CWEL, CWGL, CWIL, Series 1 to 4

Counterbalance & Load-Holding ValvesEx-stock · delivery in 3 days
Sun Hydraulics CWCL vented counterbalance valve, series 1, T-21A cavity — dimension drawing
VIEW 01·Sun Hydraulics CWCL vented counterbalance valve, series 1, T-21A cavity — dimension drawing
1 / 3

Sun Hydraulics vented counterbalance valve, 2:1 pilot ratio: CWCL, CWEL, CWGL, CWIL, series 1 to 4, 15 gpm to 120 gpm (60 L/min to 480 L/min), T-21A, T-22A, T-23A, T-24A cavities. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: Vented Counterbalance Valve
  • Capacity: 15 gpm to 120 gpm (60 L/min to 480 L/min)
  • Max operating pressure: Max setting 6000 psi (420 bar)
  • Cavity: T-21A, T-22A, T-23A, T-24A
Valve function
Vented Counterbalance Valve
Series (frame sizes)
1 to 4
Cavity
T-21A, T-22A, T-23A, T-24A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A 4-port counterbalance valve whose spring chamber is vented to its own port 4. Free flow passes into the actuator through the check (port 2 to port 1); the pilot-assisted relief stage holds the load (port 1 to port 2) until pilot pressure at port 3 lowers the setting by the pilot ratio. Because the spring chamber refers to port 4 instead of port 2, back-pressure in the return line does not change the setting.

Sizes and cavities

Sun Hydraulics builds this valve in 4 sizes. The series sets the cavity it screws into and its flow capacity:

  • CWCL — series 1, T-21A cavity, 15 gpm (60 L/min)
  • CWEL — series 2, T-22A cavity, 30 gpm (120 L/min)
  • CWGL — series 3, T-23A cavity, 60 gpm (240 L/min)
  • CWIL — series 4, T-24A cavity, 120 gpm (480 L/min)

Sun builds its cartridges in frame sizes called series, from the small series 0 to series 4. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options for control, setting and seals. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Pilot ratio: 2:1
  • Maximum setting: 6000 psi (420 bar)
  • Maximum recommended load pressure at maximum setting: 4615 psi (320 bar)
  • Maximum leakage: 5 drops/min. (0,3 cc/min)
  • Reseat: >85% of setting
  • Check cracking pressure: 40 psi (2,8 bar), 25 psi (1,7 bar), 20 psi (1,5 bar)

Configuration options

The letters after the base model code choose these options (shown for CWCL; a size may add or drop a choice):

  • Control: C — Tamper Resistant - Factory Set, L — Standard Screw Adjustment
  • Setting range: F — 1000 - 2500 psi (70 - 175 bar), 2000 psi (140 bar) Standard Setting, G — 2000 - 6000 psi (140 - 420 bar), 4000 psi (280 bar) Standard Setting
  • Seal material: N — Buna-N, V — Viton
  • Material / coating: /AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Option rules: If the modifier is /AP, the control must be C or L; If the modifier is /LH, the control must be C or L.

Selection notes

  • Set it at least 1.3 times the highest load-induced pressure.
  • Back-pressure at port 2 does not affect the setting; port 4 must be vented to tank.
  • Within one frame size, Sun's 4-port load-holding cartridges fit the same cavity and swap physically, whether counterbalance, load control or pilot-to-open check.
  • Turning the adjusting screw clockwise lowers the setting.

Where it is used

Circuits with back-pressure at the valve port: regeneration circuits, master–slave cylinders, and circuits driven by proportional or servo directional valves.

Installation and seal kits

Valve hex 7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm). Replacement seal kits — series 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, Polyurethane: 990024002, Viton: 990024006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example CWCLLGN — or send us the flow, pressure and duty and we select the valve. We confirm the full ordering code with the quotation.

Installation

ParameterValue
Valve hex size7/8 in. (22,2 mm), 1 1/8 in. (28,6 mm), 1 1/4 in. (31,8 mm), 1 5/8 in. (41,3 mm)
Installation torque30 - 35 lbf ft (41 - 47 Nm), 45 - 50 lbf ft (61 - 68 Nm), 150 - 160 lbf ft (203 - 217 Nm), 350 - 375 lbf ft (474 - 508 Nm)
Seal kitsseries 1: Buna: 990021007, Polyurethane: 990021002, Viton: 990021006; series 2: Buna: 990022007, Polyurethane: 990022002, Viton: 990022006; series 3: Buna: 990023007, Polyurethane: 990023002, Viton: 990023006; series 4: Buna: 990024007, Polyurethane: 990024002, Viton: 990024006
Weight.45 lb (0,20 kg) to 3.50 lb (1,60 kg)

Identification

ParameterValue
Valve functionVented Counterbalance Valve
Series (frame sizes)1 to 4
CavityT-21A, T-22A, T-23A, T-24A

Configuration

ParameterValue
Control / adjustmentC — Tamper Resistant - Factory Set, L — Standard Screw Adjustment
Seal materialN — Buna-N, V — Viton
Material / coating/AP — Stainless Steel, Passivated, /LH — Mild Steel, Zinc-Nickel

Performance

ParameterValue
Capacity15 gpm to 120 gpm (60 L/min to 480 L/min)
Max operating pressureMax setting 6000 psi (420 bar)
Pilot ratio2:1
Setting rangeF — 1000 - 2500 psi (70 - 175 bar), 2000 psi (140 bar) Standard Setting, G — 2000 - 6000 psi (140 - 420 bar), 4000 psi (280 bar) Standard Setting
Max leakage5 drops/min. (0,3 cc/min)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

RELATED · OFTEN PAIRED WITH