Skip to content
SUN HYDRAULICSIH-SUN-DWDF

Sun Hydraulics 3-Way, Direct-Acting, Solenoid-Operated Directional Poppet Valve (740 Series) — DWDF

Solenoid Cartridge ValvesEx-stock · delivery in 3 days
Sun Hydraulics DWDF 3-way direct-acting solenoid-operated poppet valve, series 1, T-11A cavity — dimension drawing
VIEW 01·Sun Hydraulics DWDF 3-way direct-acting solenoid-operated poppet valve, series 1, T-11A cavity — dimension drawing
1 / 3

Sun Hydraulics 3-Way, Direct-Acting, Solenoid-Operated Directional Poppet Valve (740 Series): DWDF, series 1, 7.5 gpm (30 L/min), T-11A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: 3-Way Direct-Acting Solenoid-Operated Poppet Valve
  • Capacity: 7.5 gpm (30 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-11A
Valve function
3-Way Direct-Acting Solenoid-Operated Poppet Valve
Series (frame sizes)
1
Cavity
T-11A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A direct-acting, poppet-type 3-way, 2-position valve. The poppet seals with very low leakage, and it shifts with no minimum pressure.

This version

  • Uses Sun's 740 Series coils, or 747 Series coils for hazardous locations.

Sizes and cavities

Sun Hydraulics builds this valve in one version:

  • DWDF — series 1, T-11A cavity, 7.5 gpm (30 L/min)

Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)
  • Maximum leakage: 10 drops/min.@5000 psi (0,7 cc/min.@350 bar)
  • Typical response time: 50 ms
  • Switching frequency: 15,000 max. cycles/hr

Configuration options

The letters after the base model code choose these options (shown for DWDF; a size may add or drop a choice):

  • Control: D — Twist/Lock (Dual) Manual Override, L — Twist/Lock (Detent) Manual Override, M — Manual Override, T — Twist (Momentary) Manual Override, X — No Manual Override
  • Spool / poppet configuration: A — Normally Open 1 to 2, Closed 2 to 3
  • Seal material: N — Buna-N, V — Viton, E — EPDM
  • Coil: 46 coil choices, or no coil — 12 VDC, 14 VDC, 24 VDC, 28 VDC, 115 VAC, 230 VAC; connections include DIN 43650-Form A, AMP Junior Timer, Twin Lead, Metri-Pack, Deutsch DT04-2P, Explosion Proof

Option rules: If the coil is in this group (211, 212, 212D, 214, 214D, 223, 224, 224D, 228, 228D, 612, 612D, 614, 614D, 624, 624D, 628, 628D, 712, 712D, 714, 714D, 724, 724D, 728, 728D, 812, 812D, 814, 814D, 824, 824D, 828, 828D, 912, 912D, 914, 914D, 924, 924D, 928, 928D, JM24BD, JM24CD, JN24BD, JN24CD), the range must be A or N; If the coil is in this group (JM24BD, JM24CD, JN24BD, JN24CD), the control must be M or X; If the range is N, the control must be X; If the seal is E, the control must be M or X; If the seal is E, the range must be A.

Selection notes

  • Normally closed versions close if power fails, which suits load-holding duty.
  • Port 3 is the preferred inlet; with the inlet at port 1 capacity is about half.

Where it is used

Single-acting cylinders and pilot circuits that must hold pressure without leakage.

Installation and seal kits

Hex 7/8 in. (22,2 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm). Replacement seal kits — series 1: Buna: 990411007, Viton: 990411006. Coil seal and nut kit: Viton: 990740006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example DWDFXAN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.

Performance

ParameterValue
Capacity7.5 gpm (30 L/min)
Max operating pressure5000 psi (350 bar)
Max leakage10 drops/min.@5000 psi (0,7 cc/min.@350 bar)

Identification

ParameterValue
Valve function3-Way Direct-Acting Solenoid-Operated Poppet Valve
Series (frame sizes)1
CavityT-11A

Configuration

ParameterValue
Control / adjustmentD — Twist/Lock (Dual) Manual Override, L — Twist/Lock (Detent) Manual Override, M — Manual Override, T — Twist (Momentary) Manual Override, X — No Manual Override; A — Normally Open 1 to 2, Closed 2 to 3
Seal materialN — Buna-N, V — Viton, E — EPDM

Installation

ParameterValue
Valve hex size7/8 in. (22,2 mm)
Installation torque30 - 35 lbf ft (41 - 47 Nm)
Seal kitsseries 1: Buna: 990411007, Viton: 990411006

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

Also known as

The same part, in the designations used across European and Gulf trade catalogues.

de
Hammerverschraubung Typ 740
fr
union à marteau type 740
es
unión de martillo tipo 740
it
giunto a martello tipo 740
RELATED · OFTEN PAIRED WITH