Skip to content
SUN HYDRAULICSIH-SUN-DTDF

Sun Hydraulics 2-Way, Direct-Acting, Solenoid-Operated Directional Blocking Poppet Valve (740 Series) — DTDF

Solenoid Cartridge ValvesEx-stock · delivery in 3 days
Sun Hydraulics DTDF 2-way direct-acting solenoid-operated blocking poppet valve, series 1, T-13A cavity — dimension drawing
VIEW 01·Sun Hydraulics DTDF 2-way direct-acting solenoid-operated blocking poppet valve, series 1, T-13A cavity — dimension drawing
1 / 3

Sun Hydraulics 2-Way, Direct-Acting, Solenoid-Operated Directional Blocking Poppet Valve (740 Series): DTDF, series 1, 10 gpm (40 L/min), T-13A cavity. Authorised Sun Hydraulics distributor, UAE — supplied direct from Sun.

Key features

  • Valve function: 2-Way Direct-Acting Solenoid-Operated Blocking Poppet Valve
  • Capacity: 10 gpm (40 L/min)
  • Max operating pressure: 5000 psi (350 bar)
  • Cavity: T-13A
Valve function
2-Way Direct-Acting Solenoid-Operated Blocking Poppet Valve
Series (frame sizes)
1
Cavity
T-13A
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

A direct-acting, 2-position poppet valve: the solenoid moves the poppet itself, so it shifts with no minimum pressure, and it blocks in both directions with very low leakage.

This version

  • Uses Sun's 740 Series coils, or 747 Series coils for hazardous locations.

Sizes and cavities

Sun Hydraulics builds this valve in one version:

  • DTDF — series 1, T-13A cavity, 10 gpm (40 L/min)

Sun builds its cartridges in frame sizes called series. The series fixes the cavity the valve screws into, so every function in one series shares that cavity, and a larger series carries more flow. Choose the smallest series that passes your flow at an acceptable pressure drop, using the performance curves, then the configuration options. If you are replacing a valve, the model code stamped on it gives the series and function directly, and the seal kits listed further down fit that series.

Ratings

  • Maximum operating pressure: 5000 psi (350 bar)
  • Maximum leakage: 10 drops/min.@5000 psi (0,7 cc/min.@350 bar)
  • Typical response time: 50 ms
  • Switching frequency: 15,000 max. cycles/hr

Configuration options

The letters after the base model code choose these options (shown for DTDF; a size may add or drop a choice):

  • Control: D — Twist/Lock (Dual) Manual Override, L — Twist/Lock (Detent) Manual Override, M — Manual Override, T — Twist (Momentary) Manual Override, X — No Manual Override
  • Spool / poppet configuration: C — Normally Closed, H — Normally Open
  • Seal material: L — Extended Temp. Buna, N — Buna-N, V — Viton, E — EPDM
  • Coil: 47 coil choices, or no coil — 12 VDC, 14 VDC, 24 VDC, 28 VDC, 127 VDC, 115 VAC, 230 VAC; connections include DIN 43650-Form A, AMP Junior Timer, Twin Lead, Metri-Pack, Deutsch DT04-2P, Explosion Proof

Option rules: If the coil is in this group (211, 212, 212D, 214, 214D, 223, 224, 224D, 228, 228D, 299, 612, 612D, 614, 614D, 624, 624D, 628, 628D, 712, 712D, 714, 714D, 724, 724D, 728, 728D, 812, 812D, 814, 814D, 824, 824D, 828, 828D, 912, 912D, 914, 914D, 924, 924D, 928, 928D, JM24BD, JM24CD, JN24BD, JN24CD), the range must be C or H; If the coil is in this group (JM24BD, JM24CD, JN24BD, JN24CD), the control must be M or X; If the seal is E, the control must be M or X.

Selection notes

  • Normally closed versions close if power fails, which suits load-holding duty.
  • The solenoid tube is fatigue-rated for 5,000 psi (350 bar).

Where it is used

Load holding, pilot control of larger valves, isolating accumulators and gauges.

Installation and seal kits

Hex 7/8 in. (22,2 mm); installation torque 30 - 35 lbf ft (41 - 47 Nm). Replacement seal kits — series 1: Buna: 990413007, Polyurethane: 990413002, Viton: 990413006.

Ordering

Indus Hydraulics is an authorised Sun Hydraulics distributor in the UAE and supplies the range direct from Sun Hydraulics. Quote the base model and its configuration letters — for example DTDFMCN — or describe the duty and we select the part. We confirm the full ordering code with the quotation.

Identification

ParameterValue
Valve function2-Way Direct-Acting Solenoid-Operated Blocking Poppet Valve
Series (frame sizes)1
CavityT-13A

Performance

ParameterValue
Capacity10 gpm (40 L/min)
Max operating pressure5000 psi (350 bar)
Max leakage10 drops/min.@5000 psi (0,7 cc/min.@350 bar)

Configuration

ParameterValue
Control / adjustmentD — Twist/Lock (Dual) Manual Override, L — Twist/Lock (Detent) Manual Override, M — Manual Override, T — Twist (Momentary) Manual Override, X — No Manual Override; C — Normally Closed, H — Normally Open
Seal materialL — Extended Temp. Buna, N — Buna-N, V — Viton, E — EPDM

Installation

ParameterValue
Valve hex size7/8 in. (22,2 mm)
Installation torque30 - 35 lbf ft (41 - 47 Nm)
Seal kitsseries 1: Buna: 990413007, Polyurethane: 990413002, Viton: 990413006
Weight.65 lb (0,30 kg)

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

Also known as

The same part, in the designations used across European and Gulf trade catalogues.

de
Hammerverschraubung Typ 740
fr
union à marteau type 740
es
unión de martillo tipo 740
it
giunto a martello tipo 740
RELATED · OFTEN PAIRED WITH

Engineers viewing this also looked at